Magn Reson Med ; 90(6): 2242-2260, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37598420

RESUMEN

PURPOSE: A significant source of artifacts in MRI are field fluctuations. Field monitoring is a new technology that allows measurement of field dynamics during a scan via "field probes," which can be used to improve image reconstruction. Ideally, probes are located within the volume where gradients produce nominally linear field patterns. However, in some situations probes must be located far from isocenter where rapid field variation can arise, leading to erroneous field-monitoring characterizations and images. This work aimed to develop an algorithm that improves the robustness of field dynamics in these situations. METHODS: The algorithm is split into three components. Component 1 calculates field dynamics one spatial order at a time, whereas the second implements a weighted least squares solution based on probe distance. Component 3 then calculates phase residuals and removes the residual phase for distant probes before recalculation. Two volunteers and a phantom were scanned on a 7T MRI using diffusion-weighted sequences, and field monitoring was performed. Image reconstructions were informed with field dynamics calculated conventionally, and with the correction algorithm, after which in vivo images were compared qualitatively and phantom image error was quantitatively assessed. RESULTS: The algorithm was able to correct corrupted field dynamics, resulting in image-quality improvements. Significant artifact reduction was observed when correcting higher-order fits. Stepwise fitting provided the most correction benefit, which was marginally improved when adding the other correction strategies. CONCLUSION: The proposed algorithm can mitigate effects of phase errors in field monitoring, providing improved characterization of field dynamics.

2.
Magn Reson Med ; 90(2): 615-623, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37036384

RESUMEN

PURPOSE: The expanded encoding model incorporates spatially- and time-varying field perturbations for correction during reconstruction. To date, these reconstructions have used the conjugate gradient method with early stopping used as implicit regularization. However, this approach is likely suboptimal for low-SNR cases like diffusion or high-resolution MRI. Here, we investigate the extent that ℓ 1 $$ {\ell}_1 $$ -wavelet regularization, or equivalently compressed sensing (CS), combined with expanded encoding improves trade-offs between spatial resolution, readout time and SNR for single-shot spiral DWI at 7T. The reconstructions were performed using our open-source graphics processing unit-enabled reconstruction toolbox, "MatMRI," that allows inclusion of the different components of the expanded encoding model, with or without CS. METHODS: In vivo accelerated single-shot spirals were acquired with five acceleration factors (R) (2×-6×) and three in-plane spatial resolutions (1.5, 1.3, and 1.1 mm). From the in vivo reconstructions, we estimated diffusion tensors and computed fractional anisotropy maps. Then, simulations were used to quantitatively investigate and validate the impact of CS-based regularization on image quality when compared to a known ground truth. RESULTS: In vivo reconstructions revealed improved image quality with retainment of small features when CS was used. Simulations showed that the joint use of the expanded encoding model and CS improves accuracy of image reconstructions (reduced mean-squared error) over the range of R investigated. CONCLUSION: The expanded encoding model and CS regularization are complementary tools for single-shot spiral diffusion MRI, which enables both higher spatial resolutions and higher R.


Asunto(s)
Algoritmos , Procesamiento de Imagen Asistido por Computador , Procesamiento de Imagen Asistido por Computador/métodos , Imagen de Difusión por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/métodos , Anisotropía
3.
Magn Reson Med ; 89(2): 756-766, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36198030

RESUMEN

PURPOSE: Oscillating gradient spin-echo (OGSE) sequences have demonstrated an ability to probe time-dependent microstructural features, although they often suffer from low SNR due to increased TEs. In this work we introduce frequency-tuned bipolar (FTB) gradients as a variation of oscillating gradients with reduced TE and demonstrate their utility by mapping the frequency dispersion of kurtosis in human subjects. METHODS: An FTB oscillating gradient waveform is presented that provides encoding of 1.5 net oscillation periods, thereby reducing the TE of the acquisition. Simulations were performed to determine an optimal protocol based on the SNR of kurtosis frequency dispersion-defined as the difference in kurtosis between pulsed and oscillating gradient acquisitions. Healthy human subjects were scanned at 7T using pulsed gradient and an optimized 23 Hz FTB protocol, which featured a maximum b-value of 2500 s/mm2 . In addition, to directly compare existing methods, measurements using traditional cosine OGSE were also acquired. RESULTS: FTB oscillating gradients demonstrated equivalent frequency-dependent diffusion measurements compared with cosine-modulated OGSE while enabling a significant reduction in TE. Optimization and in vivo results suggest that FTB gradients provide increased SNR of kurtosis dispersion maps compared with traditional cosine OGSE. The optimized FTB gradient protocol demonstrated consistent reductions in apparent kurtosis values and increased diffusivity in generated frequency dispersion maps. CONCLUSIONS: This work presents an alternative to traditional cosine OGSE sequences, enabling more time-efficient acquisitions of frequency-dependent diffusion quantities as demonstrated through in vivo kurtosis frequency dispersion maps.


Asunto(s)
Encéfalo , Imagen de Difusión por Resonancia Magnética , Humanos , Imagen de Difusión por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Difusión
4.
Magn Reson Med ; 87(5): 2551-2565, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34932225

RESUMEN

PURPOSE: To develop an RF coil with an integrated commercial field camera for ultrahigh field (7T) neuroimaging. The RF coil would operate within a head-only gradient coil and be subject to the corresponding design constraints. The RF coil can thereafter be used for subject-specific correction of k-space trajectories-notably in gradient-sensitive sequences such as single-shot spiral imaging. METHODS: The transmit and receive performance was evaluated before and after the integration of field probes, whereas field probes were evaluated when in an optimal configuration external to the coil and after their integration. Diffusion-weighted EPI and single-shot spiral acquisitions were employed to evaluate the efficacy of correcting higher order field perturbations and the consequent effect on image quality. RESULTS: Field probes had a negligible effect on RF-coil performance, including the transmit efficiency, transmit uniformity, and mean SNR over the brain. Modest reductions in field-probe signal lifetimes were observed, caused primarily by nonidealities in the gradient and shim fields of the head-only gradient coil at the probe positions. The field-monitoring system could correct up to second-order field perturbations in single-shot spiral imaging. CONCLUSION: The integrated RF coil and field camera was capable of concurrent-field monitoring within a 7T head-only scanner and facilitated the subsequent correction of k-space trajectories during spiral imaging.


Asunto(s)
Imagen por Resonancia Magnética , Ondas de Radio , Encéfalo/diagnóstico por imagen , Diseño de Equipo , Imagen por Resonancia Magnética/métodos , Neuroimagen/métodos , Fantasmas de Imagen
5.
Magn Reson Med ; 87(5): 2209-2223, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34894640

RESUMEN

PURPOSE: To develop and test a method for reducing artifacts due to time-varying eddy currents in oscillating gradient spin-echo (OGSE) diffusion images. METHODS: An in-house algorithm (TVEDDY), that for the first time retrospectively models eddy current decay, was tested on pulsed gradient spin echo and OGSE brain images acquired at 7 T. Image pairs were acquired using opposite polarity diffusion gradients. A three-parameter exponential decay model (two amplitudes and a time constant) was used to characterize and correct eddy current distortions by minimizing the intensity difference between image pairs. Correction performance was compared with conventional correction methods by evaluating the mean squared error (MSE) between diffusion-weighted images acquired with opposite polarity diffusion gradients. As a ground-truth comparison, images were corrected using field dynamics up to third order in space, measured using a field monitoring system. RESULTS: Time-varying eddy currents were observed for OGSE, which introduced blurring that was not reduced using the traditional approach but was diminished considerably with TVEDDY and field monitoring-informed model-based reconstruction. No MSE difference was observed between the conventional approach and TVEDDY for pulsed gradient spin echo, but for OGSE TVEDDY resulted in significantly lower MSE than the conventional approach. The field-monitoring reconstruction had the lowest MSE for both pulsed gradient spin echo and OGSE. CONCLUSION: This work establishes that it is possible to estimate time-varying eddy currents from the actual diffusion data, which provides substantial image-quality improvements for gradient-intensive diffusion MRI acquisitions like OGSE.


Asunto(s)
Artefactos , Imagen de Difusión por Resonancia Magnética , Algoritmos , Encéfalo/diagnóstico por imagen , Difusión , Imagen de Difusión por Resonancia Magnética/métodos , Imagen Eco-Planar/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Estudios Retrospectivos