1.
Talanta ; 146: 166-74, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26695248

RESUMEN

A method has been developed for the determination of lead in biomass, bio-oil, pyrolysis aqueous phase, and biomass ashes by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS) and direct solid or liquid sample analysis. All measurements were performed without chemical modifier and calibration could be carried out using aqueous standard solutions. A pyrolysis temperature of 800°C and an atomization temperature of 2200°C were applied. The limits of detection and quantification were, respectively, 0.5 µg kg(-1) and 2 µg kg(-1) using the analytical line at 217.001 nm and 6 µg kg(-1) and 19 µg kg(-1) at 283.306 nm. The precision, expressed as relative standard deviation, was between 3% and 10%, which is suitable for direct analysis. The lead concentrations found for the solid samples varied between 0.28 and 1.4 mg kg(-1) for biomass and between 0.25 and 2.3 mg kg(-1) for ashes, these values were much higher than those found for bio-oil (2.2-16.8 µg kg(-1)) and pyrolysis aqueous phase (3.2-18.5 µg kg(-1)). After the determination of lead in the samples, it was possible to estimate the relative distribution of this element in the fractions of the pyrolysis products, and it was observed that most of the lead present in the biomass was eliminated to the environment during the pyrolysis process, with a significant portion retained in the ashes.


Asunto(s)
Biomasa , Grafito/química , Plomo/análisis , Espectrofotometría Atómica/métodos , Reproducibilidad de los Resultados , Temperatura , Factores de Tiempo , Agua/química
2.
Talanta ; 115: 55-60, 2013 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-24054561

RESUMEN

High-resolution continuum source graphite furnace atomic absorption spectrometry, because of the use of only one radiation source for all elements, offers the possibility of sequential determination of two or more elements from the same sample aliquot if their volatilities are significantly different. Cd and Cr were determined sequentially in samples of biomass and biomass ashes employing direct solid sample analysis. The use of a chemical modifier was found to be not necessary, and calibration could be carried out using aqueous standard solutions. A pyrolysis temperature of 400°C and an atomization temperature of 1500°C were used for the determination of Cd; no losses of Cr were observed at this temperature. After the atomization of Cd the wavelength was changed and Cr atomized at 2600°C. The limits of detection (LOD) and quantification (LOQ) were 1.1 µg kg(-1) and 3.7 µg kg(-1), respectively, for Cd and 21 µg kg(-1) and 70 µg kg(-1), respectively, for Cr using the most sensitive line at 357.869 nm, or 90 µg kg(-1) and 300 µg kg(-1), respectively, using the less sensitive line at 428.972 nm. The precision, expressed as relative standard deviation was around 10%, which is typical for direct solid sample analysis. The values found for Cd in biomass samples were between <1.1 µg kg(-1) and 789 µg kg(-1), whereas those for Cr were between 7.9 mg kg(-1) and 89 mg kg(-1); the values found in the ashes were significantly lower for Cd, between <1.1 µg kg(-1) and 6.3 µg kg(-1), whereas the trend was not so clear for Cr, where the values were between 3.4 mg kg(-1) and 28 mg kg(-1).


Asunto(s)
Cadmio/análisis , Cromo/análisis , Saccharum/química , Biomasa , Calibración , Grafito , Calor , Límite de Detección , Espectrofotometría Atómica , Residuos