1.
Med Image Anal ; 5(4): 237-54, 2001 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-11731304

RESUMEN

Magnetic resonance elastography (MRE) is a phase-contrast-based MRI imaging technique that can directly visualize and quantitatively measure propagating acoustic strain waves in tissue-like materials subjected to harmonic mechanical excitation. The data acquired allows the calculation of local quantitative values of shear modulus and the generation of images that depict tissue elasticity or stiffness. This is significant because palpation, a physical examination that assesses the stiffness of tissue, can be an effective method of detecting tumors, but is restricted to parts of the body that are accessible to the physician's hand. MRE shows promise as a potential technique for 'palpation by imaging', with possible applications in tumor detection (particularly in breast, liver, kidney and prostate), characterization of disease, and assessment of rehabilitation (particularly in muscle). We describe MRE in the context of other recent techniques for imaging elasticity, discuss the processing algorithms for elasticity reconstruction and the issues and assumptions they involve, and present recent ex vivo and in vivo results.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Acústica , Algoritmos , Animales , Fenómenos Biomecánicos , Encefalopatías/diagnóstico , Neoplasias de la Mama/diagnóstico , Elasticidad , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Músculo Esquelético/fisiología , Fantasmas de Imagen , Enfermedades de la Próstata/diagnóstico , Estrés Mecánico
2.
J Magn Reson Imaging ; 13(2): 269-76, 2001 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-11169834

RESUMEN

While the contractile properties of skeletal muscle have been studied extensively, relatively little is known about the elastic properties of muscle in vivo. Magnetic resonance elastography (MRE) is a phase contrast-based method for observing shear waves propagating in a material to determine its stiffness. In this work, MRE is applied to skeletal muscle under load to quantify the change in stiffness with loading. A mathematical model of muscle is developed that predicts a linear relationship between shear stiffness and muscle load. The MRE technique was applied to bovine muscle specimens (N = 10) and human biceps brachii in vivo (N = 5). Muscle stiffness increased linearly for both passive tension (14.5 +/- 1.77 kPa/kg) and active tension, in which the increase in stiffness was dependent upon muscle size, as predicted by the model. A means of noninvasively assessing the viscoelastic pro-perties of skeletal muscle in vivo may provide a useful method for studying muscle biomechanics in health and disease.


Asunto(s)
Contracción Isométrica/fisiología , Imagen por Resonancia Magnética/métodos , Músculo Esquelético/fisiología , Soporte de Peso/fisiología , Animales , Fenómenos Biomecánicos , Bovinos , Elasticidad , Humanos , Músculo Esquelético/patología , Valores de Referencia
3.
Phys Med Biol ; 45(6): 1579-90, 2000 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-10870712

RESUMEN

The well-documented effectiveness of palpation as a diagnostic technique for detecting cancer and other diseases has provided motivation for developing imaging techniques for noninvasively evaluating the mechanical properties of tissue. A recently described approach for elasticity imaging, using propagating acoustic shear waves and phase-contrast MRI, has been called magnetic resonance elastography (MRE). The purpose of this work was to conduct preliminary studies to define methods for using MRE as a tool for addressing the paucity of quantitative tissue mechanical property data in the literature. Fresh animal liver and kidney tissue specimens were evaluated with MRE at multiple shear wave frequencies. The influence of specimen temperature and orientation on measurements of stiffness was studied in skeletal muscle. The results demonstrated that all of the materials tested (liver, kidney, muscle and tissue-simulating gel) exhibit systematic dependence of shear stiffness on shear rate. These data are consistent with a viscoelastic model of tissue mechanical properties, allowing calculation of two independent tissue properties from multiple-frequency MRE data: shear modulus and shear viscosity. The shear stiffness of tissue can be substantially affected by specimen temperature. The results also demonstrated evidence of shear anisotropy in skeletal muscle but not liver tissue. The measured shear stiffness in skeletal muscle was found to depend on both the direction of propagation and polarization of the shear waves.


Asunto(s)
Ultrasonografía/métodos , Animales , Elasticidad , Procesamiento de Imagen Asistido por Computador , Riñón/diagnóstico por imagen , Hígado/diagnóstico por imagen , Imagen por Resonancia Magnética , Modelos Estadísticos , Modelos Teóricos , Músculo Esquelético/diagnóstico por imagen , Fantasmas de Imagen , Porcinos , Temperatura
4.
Brain Topogr ; 10(4): 245-53, 1998.
Artículo en Inglés | MEDLINE | ID: mdl-9672223

RESUMEN

Scalp-recorded EEG is a noninvasive and widely available tool for studying normal and dysfunctional human neurophysiology with unsurpassed temporal resolution. However, scalp-recorded EEG data is difficult to correlate with anatomy, and most current display and neural source estimation algorithms are based on unrealistic spherical or elliptical models of the head. It is possible to measure the positions of electrodes on the patient's scalp, and to register those electrode positions into the space of a high-resolution MRI volume, and to then use the patient-specific anatomy as the basis for display and estimation of neural sources. We use a surface matching algorithm to register digitized electrode and scalp surface coordinates to a three-dimensional MRI volume. This study uses fiducial markers in phantom and volunteer studies to quantitatively estimate the accuracy of the electrode registration method. Our electrode registration procedure is accurate to 2.21 mm for a realistic head phantom and accurate to 4.16 mm on average for five volunteers. This level of accuracy is considered within acceptable limits for clinical applications.


Asunto(s)
Encéfalo/anatomía & histología , Encéfalo/fisiología , Electroencefalografía , Imagen por Resonancia Magnética , Cuero Cabelludo/fisiopatología , Algoritmos , Procesamiento Automatizado de Datos , Humanos , Variaciones Dependientes del Observador , Fantasmas de Imagen
SELECCIÓN DE REFERENCIAS