Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Phys Med Biol ; 49(6): 997-1005, 2004 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-15104322

RESUMEN

Radiation fields involved in angiographic suites are most uneven with intensity and gradient varying widely with projection geometry. The European Commission DIMOND III project addressed among others, the issues regarding optimization of staff doses with an attempt to propose preliminary occupational dose constraints. Two thermoluminescent dosemeters (TLD) were used to assess operators' extremity doses (left shoulder and left foot) during 20 coronary angiographies (CAs) and 20 percutaneous transluminal coronary angioplasties (PTCAs) in five European centres. X-ray equipment, radiation protection measures used and the dose delivered to the patient in terms of dose-area product (DAP) were recorded so as to subsequently associate them with operator's dose. The range of staff doses noted for the same TLD position, centre and procedure type emphasizes the importance of protective measures and technical characteristics of x-ray equipment. Correlation of patient's DAP with staff shoulder dose is moderate whereas correlation of patient's DAP with staff foot dose is poor in both CA and PTCA. Therefore, it is difficult to predict operator's dose from patient's DAP mainly due to the different use of protective measures. A preliminary occupational dose constraint value was defined by calculating cardiologists' annual effective dose and found to be 0.6 mSv.


Asunto(s)
Angioplastia Coronaria con Balón/estadística & datos numéricos , Angiografía Coronaria/estadística & datos numéricos , Exposición Profesional/análisis , Exposición Profesional/estadística & datos numéricos , Protección Radiológica/métodos , Medición de Riesgo/métodos , Dosimetría Termoluminiscente/métodos , Carga Corporal (Radioterapia) , Cardiología/estadística & datos numéricos , Europa (Continente)/epidemiología , Unión Europea/estadística & datos numéricos , Humanos , Especificidad de Órganos , Dosis de Radiación , Protección Radiológica/normas , Protección Radiológica/estadística & datos numéricos , Radiología Intervencionista/estadística & datos numéricos , Medición de Riesgo/normas , Hombro , Dosimetría Termoluminiscente/normas , Dosimetría Termoluminiscente/estadística & datos numéricos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA