The aim of this study was to evaluate on-line performance of a real-time digital imaging system based on amorphous silicon technology and to compare it with conventional film-screen equipment. The digital detecting imager consists of (1) a converter, which transforms the energy of the incident X rays into light; (2) a real-time digital detecting system, capable of producing as many as 10 pictures per second using a large-area pixel matrix (20 x 20 cm2) based on solid-state amorphous silicon sensor technology with a pitch of 400 microns; and (3) appropriate computer tools for control, real-time image treatment, data representation, and off-line analysis. Different phantoms were used for qualitative comparison with the conventional film-screen technique, with images obtained with both systems at the normal dose (used as a reference), as well as with dose reduction by a factor of 10 to 100. Basic image quality parameters evaluated showed that the response of the detector is linear in a wide range of entrance air kerma; the dynamic range is higher compared with the conventional film-screen combination; the spatial resolution is 1.25 lp per millimeter, as expected from the pixel size; and good image quality is ensured at doses substantially lower than for the film-screen technique. The flat-panel X-ray imager based on amorphous silicon technology implemented in standard radiographic equipment permits acquisition of real-time images in radiology (as many as 10 images per second) of diagnostic quality with a marked reduction of dose (as much as 100 times) and better contrast compared with the standard film technique. Preliminary results obtained with a 100-micron pitch imager based on the same technology show better quality but a less substantial dose reduction. Applications in craniofacial surgery look promising.


Asunto(s)
Cara/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Intensificación de Imagen Radiográfica/métodos , Cráneo/diagnóstico por imagen , Conversión Analogo-Digital , Diseño de Equipo , Humanos , Procesamiento de Imagen Asistido por Computador/instrumentación , Sistemas en Línea , Fantasmas de Imagen , Dosis de Radiación , Intensificación de Imagen Radiográfica/instrumentación , Silicio , Tecnología Radiológica/instrumentación , Película para Rayos X , Pantallas Intensificadoras de Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA