Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38755520

RESUMEN

BACKGROUND: The LUX-Dx™ is a novel insertable cardiac monitor (ICM) introduced into the European market since October 2022. PURPOSE: The aim of this investigation was to provide a comprehensive description of the ICM implantation experience in Europe during its initial year of commercial use. METHODS: The system comprises an incision tool and a single-piece insertion tool pre-loaded with the small ICM. The implantation procedure involves incision, creation of a device pocket, insertion of the ICM, verification of sensing, and incision closure. Patients receive a mobile device with a preloaded App, connecting to their ICM and transmitting data to the management system. Data collected at European centers were analyzed at the time of implantation and before patient discharge. RESULTS: A total of 368 implantation procedures were conducted across 23 centers. Syncope (235, 64%) and cryptogenic stroke (34, 9%) were the most frequent indications for ICM. Most procedures (338, 92%) were performed in electrophysiology laboratories. All ICMs were successfully implanted in the left parasternal region, oriented at 45° in 323 (88%) patients. Repositioning was necessary after sensing verification in 9 (2%) patients. No procedural complications were reported, with a median time from skin incision to suture of 4 min (25th-75th percentiles 2-7). At implantation, the mean R-wave amplitude was 0.39 ± 0.30 mV and the P-wave visibility was 91 ± 20%. Sensing parameters remained stable until pre-discharge and were not influenced by patient characteristics or indications. Procedural times were fast, exhibited consistency across patient groups, and improved after an initial experience with the system. Operator Operator feedback on the system was positive. Patients reported very good ease of use of the App and low levels of discomfort after implantation. CONCLUSIONS: LUX-Dx™ implantation appears efficient and straightforward, with favorable post-implantation sensing values and associated with positive feedback from operators and patients.

2.
J Mol Biol ; 428(14): 2931-42, 2016 07 17.
Artículo en Inglés | MEDLINE | ID: mdl-27117189

RESUMEN

The nucleosome remodeling deacetylase (NuRD) complex is a highly conserved regulator of chromatin structure and transcription. Structural studies have shed light on this and other chromatin modifying machines, but much less is known about how they assemble and whether stable and functional sub-modules exist that retain enzymatic activity. Purification of the endogenous Drosophila NuRD complex shows that it consists of a stable core of subunits, while others, in particular the chromatin remodeler CHD4, associate transiently. To dissect the assembly and activity of NuRD, we systematically produced all possible combinations of different components using the MultiBac system, and determined their activity and biophysical properties. We carried out single-molecule imaging of CHD4 in live mouse embryonic stem cells, in the presence and absence of one of core components (MBD3), to show how the core deacetylase and chromatin-remodeling sub-modules associate in vivo. Our experiments suggest a pathway for the assembly of NuRD via preformed and active sub-modules. These retain enzymatic activity and are present in both the nucleus and the cytosol, an outcome with important implications for understanding NuRD function.


Asunto(s)
Histona Desacetilasas/metabolismo , Complejo Desacetilasa y Remodelación del Nucleosoma Mi-2/metabolismo , Nucleosomas/metabolismo , Animales , Núcleo Celular/metabolismo , Cromatina/metabolismo , Ensamble y Desensamble de Cromatina/fisiología , Citosol/metabolismo , Drosophila/metabolismo , Ratones , Subunidades de Proteína/metabolismo , Células Madre/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA