Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 79(4): 044702, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18447539

RESUMEN

We realized a tunable continuous-wave terahertz source with megahertz frequency resolution. The system is based on optical heterodyning of two near-infrared distributed feedback diode lasers, each laser being stabilized by electronic feedback from a low-finesse quadrature interferometer. The control loop permits precisely linear laser frequency scans over >1200 GHz, and a beat signal linewidth of 1 MHz at 80 ms time scale. Using GaAs photomixers and log-periodic antennae, we achieve a signal-to-noise ratio of the terahertz power of >70 dB at 100 GHz and 100 ms integration time, and still approximately 30 dB at 1 THz. As an example for high-resolution terahertz spectroscopy, we characterize the transmission properties of a subwavelength metal grating.

2.
J Appl Physiol (1985) ; 98(6): 2259-67, 2005 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-15640396

RESUMEN

A recently developed method for quantitative assessment of regional lung ventilation was employed for the study of posture-dependent ventilation differences in rats. The measurement employed hyperpolarized (3)He MRI to detect the build-up of the signal intensity after increasing numbers of (3)He breaths, which allowed for computation of a regional ventilation parameter. A group of six anesthetized rats was studied in both supine and prone postures. Three-dimensional maps of the ventilation parameter were obtained with high spatial resolution (voxel volume approximately 2 mm(3)). Vertical (dorsal-ventral) gradients of the ventilation index, defined as the regional ventilation normalized by the average ventilation within the whole lung, were investigated. Variations in the regional distribution of the ventilation parameter, as well as of the ventilation index, could be detected, depending on the posture of the rats. In supine posture, ventilation was elevated in the dependent parts of the lungs, with a linear gradient of the ventilation index of -0.11 +/- 0.03 cm(-1). In prone posture, the distribution of ventilation was more uniform, with a significantly (P < 0.001) smaller gradient of the ventilation index of -0.01 +/- 0.02 cm(-1). It is concluded that the (3)He MRI-based method can detect and quantify regional ventilation gradients in animals as small as the rat and that these gradients depend on prone or supine posture of the animal.


Asunto(s)
Algoritmos , Helio , Interpretación de Imagen Asistida por Computador/métodos , Pulmón/fisiología , Imagen por Resonancia Magnética/métodos , Postura/fisiología , Ventilación Pulmonar/fisiología , Administración por Inhalación , Animales , Medios de Contraste , Helio/administración & dosificación , Imagenología Tridimensional/métodos , Isótopos/administración & dosificación , Pulmón/anatomía & histología , Hombres , Posición Prona/fisiología , Ratas , Ratas Sprague-Dawley , Posición Supina/fisiología
3.
Magn Reson Med ; 48(2): 223-32, 2002 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-12210930

RESUMEN

A new strategy for a quantitative measurement of regional pulmonary ventilation using hyperpolarized helium-3 (3He) MRI has been developed. The method employs the build-up of the signal intensity after a variable number of (3)He breaths. A mathematical model of the signal dynamics is presented, from which the local ventilation, defined as the fraction of gas exchanged per breath within a given volume, is calculated. The model was used to create ventilation maps of coronal slices of guinea pig lungs. Ventilation values very close to 1 were found in the trachea and the major airways. In the lung parenchyma, regions adjacent to the hilum showed values of 0.6-0.8, whereas 0.2-0.4 was measured in peripheral regions. Monte Carlo simulations were used to investigate the accuracy of the method and its limitations. The simulations revealed that, at presently attainable signal-to-noise ratios, the ventilation parameter can be determined with a relative uncertainty of <5% over a wide range of values.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Ventilación Pulmonar , Animales , Cobayas , Helio , Procesamiento de Imagen Asistido por Computador , Isótopos , Masculino , Intercambio Gaseoso Pulmonar , Ventilación Pulmonar/fisiología , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA