Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Orthop Traumatol Surg Res ; 104(2): 185-191, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29274863

RESUMEN

INTRODUCTION: The "ball-in-socket" design of the Medial-Pivot knee system (MicroPort Orthopedics, Arlington, Tennessee, USA) aims to reproduce normal knee kinematics by medializing its rotational axis. The goal of this study was to measure knee range of motion (ROM) with this implant after a mean follow-up of 10 years and to report the survivorship and long-term clinical and radiological outcomes. We hypothesized the prosthetic knee would have at least 120° flexion at 10 years. MATERIAL AND METHODS: This was retrospective, single-centre study of 74 Medial-Pivot knees implanted in 71 patients (average age of 69 years) between May 2005 and November 2007. All patients who received a Medial-Pivot knee were included consecutively. The mean follow-up was 10 years. Clinical and radiological assessments were performed using the Knee Society Score (KSS) and Ewald's score. Kaplan-Meir survival analysis was used to calculate survivorship. RESULTS: Seven percent of cases were lost to follow-up. The knee ROM was 110° at 10 years. The survivorship was 93% for all revision causes and 95.9% when revisions due to trauma or infection were excluded. The mean KSS score was 195. Stable radiolucent lines were found in 14% of cases. No aseptic loosening was observed. CONCLUSION: Our hypothesis was not confirmed. Knee flexion at the final follow-up was comparable to other semi-constrained implant designs but was not as large as expected. The survival of the Medial-Pivot knee at 10 years is good. Its radiological and clinical outcomes are satisfactory. LEVEL OF EVIDENCE: IV (retrospective cohort study).


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/fisiopatología , Prótesis de la Rodilla , Adulto , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Femenino , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Falla de Prótesis , Radiografía , Rango del Movimiento Articular , Estudios Retrospectivos
2.
J Hand Surg Eur Vol ; 42(6): 592-598, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28166695

RESUMEN

The aim of this study was to assess the clinical and radiological results of the Rubis II thumb carpometacarpal joint reverse prosthesis, at a mean follow-up of 10 years. Between 1997 and 2008, 253 prostheses were implanted in 199 patients; 115 were reviewed. The survival after a mean of 10 years was 89%. At the last follow-up, 70% of prostheses were painless; the others reported moderate or intermittent pain. The satisfaction rate was 98%. The mean opposition was 9 on the Kapandji scale; the mean QuickDASH score was 30. Wrist, key and tip pinch strengths were comparable with the non-operated side. Of the 115 implants, one was radiologically loose (1%) and 15 had suffered dislocations (13%), 12 of which were caused by an injury. Eleven thumbs had revision surgery. This study confirms that the good clinical results of the Rubis II prosthesis are maintained in the medium and long term, and represents a useful alternative to trapeziectomy for selected patients. LEVEL OF EVIDENCE: IV.


Asunto(s)
Artroplastia de Reemplazo , Articulaciones Carpometacarpianas , Prótesis Articulares , Osteoartritis/cirugía , Pulgar , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis/diagnóstico por imagen , Osteoartritis/fisiopatología , Satisfacción del Paciente , Fuerza de Pellizco , Radiología , Rango del Movimiento Articular , Reoperación , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA