1.
G Ital Nefrol ; 21 Suppl 30: S62-6, 2004.
Artículo en Italiano | MEDLINE | ID: mdl-15747307

RESUMEN

HFR is an integrated hemodiafiltration system that utilizes a double chamber filter to separate convection from diffusion. The ultrafiltrate is regenerated by passage through a sorbent cartridge made up of resin and activated carbon. A small percentage of patients using this technique had gastrointestinal symptoms that included nausea/vomiting, diarrhea and/or stomach cramps approximately 1-2 hours after the start of HFR. We undertook a series of investigations to try and elucidate the cause of these reactions. Since the majority of the patients were taking ACE inhibitors, attention was focused on contact phase activation. Healthy and uremic plasma were incubated with different components of the HFR circuit. The activated carbon caused a moderate activation of factor XII and production of kallikrein, while there was no activation for the lines, double filter or resin. Patients taking ACE inhibitors may be at risk for treatments involved with contact phase activation as ACE inhibitors also block the degradation of bradykinin. A new sorbent cartridge has now been developed that contains only resin.


Asunto(s)
Carbono/fisiología , Hemodiafiltración/métodos , Inhibidores de la Enzima Convertidora de Angiotensina/farmacología , Interacciones Farmacológicas , Factor XII/efectos de los fármacos , Hemodiafiltración/efectos adversos , Humanos , Calicreínas/efectos de los fármacos
2.
G Ital Nefrol ; 21 Suppl 30: S71-4, 2004.
Artículo en Italiano | MEDLINE | ID: mdl-15747310

RESUMEN

Adsorbent therapies have become increasingly popular over the last several years as they permit an additional method to selectively or non-selectively remove toxins. Adsorbents offer a unique removal strategy as they have an extremely high adsorption capacity due to their great surface area. This paper describes experiments that utilized a synthetic divinylbenzene styrenic resin cartridge to remove uremic toxins from chronic renal failure patients. The resin-only cartridge was tested as an alternative after a small number of patients (primarily taking ACE inhibitors) experienced gastrointestinal problems using hemodiafiltration with on-line regeneration (HFR). Subsequent laboratory evidence suggested that the particular carbon used in the cartridge was able to activate contact phase activation. This could potentially cause problems in patients taking ACE inhibitors, as they are unable to degrade bradykinin efficiently. The resin-only cartridge was tested in at 6 centers throughout Italy and included patients that had experienced previous reactions to the carbon-resin cartridge. At the conclusion of the study, no adverse reactions were reported and the cartridge exhibited excellent removal of b2 microglobulin and angiogenin.


Asunto(s)
Hemodiafiltración/instrumentación , Adulto , Carbono , Humanos , Uremia/metabolismo , Uremia/terapia
4.
Int J Artif Organs ; 25(9): 832-7, 2002 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-12403398

RESUMEN

Ethylene oxide (ETO) is presently the most commonly used sterilization method for medical devices. Although alternative sterilization modes such as steam sterilization have been suggested, the effect of steam on dialysis-induced cytokine release is unknown. We enrolled 9 patients on chronic hemodialysis and evaluated at different intervals IL-1beta production while treated with ETO (NC 1785-Bellco) and steam sterilized NC 1785S-Bellco) Synthetically Modified Cellulose (SMC). A basal test during treatment with NC 1785 was performed (A); the same test was set up 4 weeks after treatment with NC 1785S (B) and, lastly, 4 weeks after returning to NC 1785 (C). Peripheral blood mononuclear cells (PBMC) were purified before and after the dialysis session, were isolated on a Ficoll/Hypaque gradient and incubated for 24 h. Spontaneous IL-1beta release was evaluated in the supernatant and in the lysate. In A, IL-1beta levels were (in pg/ml/10(6) cells, in supematant and lysate, respectively): 5.8 +/- 4.8 and 7.6+/-5.2 in pre-HD and 4.68 +/- 3.6 and 9.7 +/- 6.65 in post-HD. These levels showed a clear reduction in B: 2.5 +/- 2.2 and 4.4 +/- 3.1 in pre-HD, and 4.35+/- 6.6 and 7.52 +/- 7.22 in post-HD. In the C test, 4 weeks after the return to the ETO membrane, IL-1beta levels remained unchanged: 2.9 +/- 1.8 and 4.5 +/- 3.1 in pre-HD; and 2.6 +/- 3 and 5.7 +/- 6.6 in post-HD. Statistical analysis showed significant changes in the pre-HD levels both in supematant (p < 0.04) and in lysate (p < 0.04). Steam sterilization of SMC induced a lower spontaneous IL-1beta release, but this effect was not statistically significant due to the large inter-individual variation. Hence, contrary to claims of better biocompatibility, steam sterilization does not result in a reduced production of pro-inflammatory IL-1beta.


Asunto(s)
Interleucina-1/análisis , Diálisis Renal , Vapor , Esterilización/métodos , Materiales Biocompatibles , Células Cultivadas , Celulosa/química , Desinfectantes/uso terapéutico , Escherichia coli/química , Óxido de Etileno/uso terapéutico , Humanos , Prueba de Limulus , Membranas Artificiales , Persona de Mediana Edad , Factor de Necrosis Tumoral alfa/análisis
6.
Ren Fail ; 23(3-4): 411-8, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11499556

RESUMEN

Blood tubings commonly represent an integral component of hemodialysis circuits. Different factors may influence their biocompatibility, such as the type of material, the sterilization mode and the geometry. In vivo the final biocompatibility may be further complicated by the individual host response, the flow parameters, and the impact of mechanical trauma on blood's cellular components (i.e. erythrocytes). In this in vitro study we evaluated some commercially available blood tubings sterilized by different methods as to their interaction with normal leukocyte population and tested the response of these cells in terms of cytokines (IL-1beta, IL-1Ra, TNF-alpha). As a positive control, leukocytes were incubated with 0.5 ng/mL of bacterial lipopolysaccharide (LPS) or with Cuprophan of comparable surface. The results showed that cytokine production was markedly reduced, particularly in the case of gamma-ray-sterilized tubings. Of interest, it was not always related to the adherence. However in some cases, particularly of gamma-ray sterilization, adherence was none, despite the cytokine production.


Asunto(s)
Citocinas/metabolismo , Diálisis Renal/instrumentación , Esterilización , Apoptosis , Humanos , Técnicas In Vitro , Interleucina-1/metabolismo , Factor de Necrosis Tumoral alfa/metabolismo
7.
Int J Artif Organs ; 24(11): 765-76, 2001 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-11797846

RESUMEN

Adsorption may notably contribute to the removal of uremic toxins and to the efficiency of hemodialysis. We examined different uncoated stationary matrixes, charcoals and synthetic resins to establish their adsorptive capacities in relation to low (urea, creatinine) and high molecular weight (beta2-microglobulin, myoglobin) compounds in in vitro conditions (steady state and flow-through) using isotonic solutions or uremic ultrafiltrate. Trace metal, particle release analyses and scanning electron microscopy of different adsorbents were performed. Dynamic flow-distribution studies were made using 99Technetium and analysing the different regions of interest by single head gamma-camera. We show that adsorbents may differ greatly as to their adsorptive capacity depending on flow rate, nature, and total mass of the compounds to be removed from the ultrafiltrate. These studies suggest a methodological approach for screening stationary matrixes for possible application in hemodialysis.


Asunto(s)
Soluciones para Hemodiálisis/análisis , Soluciones para Hemodiálisis/farmacología , Diálisis Renal/efectos adversos , Diálisis Renal/instrumentación , Adsorción , Creatinina/sangre , Hemodiafiltración/efectos adversos , Hemodiafiltración/instrumentación , Humanos , Técnicas In Vitro , Fallo Renal Crónico/terapia , Microscopía Electrónica de Rastreo , Mioglobina/sangre , Diálisis Renal/métodos , Oligoelementos/sangre
8.
J Nephrol ; 14 Suppl 4: S22-9, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11798142

RESUMEN

This study focuses on the mechanisms responsible for monocyte activation and enhanced cytokine production in hemodialysis. Particular emphasis is given to recent recognition of a link between cytokine production and chronic inflammation following long-term complications in today's hemodialysis population, namely cardiovascular disease and malnutrition.


Asunto(s)
Citocinas/metabolismo , Diálisis Renal , Enfermedad Crónica , Humanos , Inflamación/etiología , Inflamación/fisiopatología , Diálisis Renal/efectos adversos
9.
Kidney Int Suppl ; 76: S148-55, 2000 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-10936812

RESUMEN

The pathophysiology of sepsis offers a highly complicated scenario. In sepsis, endotoxin or other gram-positive-derived products induce a complex and dynamic cellular response, giving rise to several mediators known to be relevant in the pathogenesis of septic shock such as specific mediators, substances responsible for up- or down-regulation of cytokine receptors and cytokine antagonists, inactivators of translational or transductional pathways, and precursor molecules. In this review, we delve into some new concepts stemming up from the use of sorbents in continuous plasma filtration. Nonspecific simultaneous removal of several mediators of the inflammatory cascade have led to improved outcomes in animal models of septic shock and to improved hemodynamics in a pilot clinical study. It seems of great importance to explore all possible treatment techniques that may have a direct impact on circulating mediators of sepsis and that also may interfere with the imbalance between proinflammatory and anti-inflammatory substances in the critically ill patient with multiple organ failure. In this view, the application of sorbents appears to open new and interesting therapeutic options. The search for innovative treatments specifically targeted to the special needs of the critically ill patients seems therefore more important than the attempt to adjust concepts and technologies that are normally applied to patients with chronic renal failure.


Asunto(s)
Fallo Renal Crónico/etiología , Sepsis/complicaciones , Sepsis/fisiopatología , Adsorción , Animales , Humanos , Fallo Renal Crónico/inmunología , Fallo Renal Crónico/terapia , Diálisis Renal , Sepsis/inmunología
10.
J Immunol Methods ; 193(1): 51-62, 1996 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-8690930

RESUMEN

A sandwich amperometric enzyme immunoassay with flow injection for alpha-fetoprotein in human serum has been developed with alkaline phosphatase as the enzyme label. p-Hydroxyphenyl phosphate was used as the substrate for alkaline phosphatase. The hydrolysis product, hydroquinone, was detected by oxidative amperometry in a flow injection system. The amperometric wall jet detector was fitted with a glassy carbon working electrode held at 350 mV vs. Ag/AgCl. The detection limit of hydroquinone in 30 mM borate buffer pH 9.5 was 1.2 x 10(-10) M (linearity range: 10(-9)-5.12 x 10(-6 M). A detection limit for free alkaline phosphatase of 1.2 x 10(-15) M (linearity range: 10(-15)-10(-13) M), or about 36 000 molecules, was observed (same borate buffer and incubations of 10 min at 25 degrees C). These conditions were maintained for the amperometric alpha-fetoprotein immunoassay. For comparison purposes, a photometric detection system was set up, with p-nitrophenyl phosphate as enzyme substrate and the same pair of antibodies and incubation conditions. The detection limit for alpha-fetoprotein obtained by amperometry, 0.07 ng/ml (linearity range = 5-500 ng/ml), was 14 times lower than by photometry. The amperometric enzyme immunoassay correlates well with a commercial colorimetric immunoassay (r = 0.986, slope = 0.967, n = 240).


Asunto(s)
Técnicas para Inmunoenzimas , alfa-Fetoproteínas/análisis , Fosfatasa Alcalina/normas , Calibración , Electroquímica/normas , Humanos , Hidroquinonas/normas , Técnicas para Inmunoenzimas/instrumentación , Técnicas para Inmunoenzimas/normas , Fotometría , Especificidad por Sustrato , alfa-Fetoproteínas/normas