Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
IEEE Trans Biomed Eng ; PP2024 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-38875099

RESUMEN

OBJECTIVE: Wearable ultrasound is emerging as a new paradigm of real-time imaging in freely moving humans and has wide applications from cardiovascular health monitoring to human gesture recognition. However, current wearable ultrasound devices have typically employed pulse-echo imaging which requires high excitation voltages and sampling rates, posing safety risks, and requiring specialized hardware. Our objective was to develop and evaluate a wearable ultrasound system based on time delay spectrometry (TDS) that utilizes low-voltage excitation and significantly simplified instrumentation. METHODS: We developed a TDS-based ultrasound system that utilizes continuous, frequency-modulated sweeps at low excitation voltages. By mixing the transmit and receive signals, the system digitizes the ultrasound signal at audio frequency (kHz) sampling rates. Wearable ultrasound transducers were developed, and the system was characterized in terms of imaging performance, acoustic output, thermal characteristics, and applications in musculoskeletal imaging. RESULTS: The prototype TDS system is capable of imaging up to 6 cm of depth with signal-to-noise ratio of up to 42 dB at a spatial resolution of 0.33 mm. Acoustic and thermal radiation measurements were within clinically safe limits for continuous ultrasound imaging. We demonstrated the ability to use a 4-channel wearable system for dynamic imaging of muscle activity. CONCLUSION: We developed a wearable ultrasound imaging system using TDS to mitigate challenges with pulse echo-based wearable ultrasound imaging systems. Our device is capable of high-resolution, dynamic imaging of deep-seated tissue structures and is safe for long-term use. SIGNIFICANCE: This work paves the way for low-voltage wearable ultrasound imaging devices with significantly reduced hardware complexity.

2.
J Immunol Res ; 2014: 361419, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25032226

RESUMEN

The attention on CeO2-NPs environmental and in vivo effects is due to their presence in diesel exhaust and in diesel filters that release a more water-soluble form of ceria NPs, as well as to their use for medical applications. In this work, acute and subacute in vivo toxicity assays demonstrate no lethal effect of these NPs. Anyhow, performing in vivo evaluations on CD-1 mouse systems, we demonstrate that it is even not correct to assert that ceria NPs are harmless for living systems as they can induce status of inflammation, revealed by hematological-chemical-clinical assays as well as histological and TEM microscope observations. TEM analysis showed the presence of NPs in alveolar macrophages. Histological evaluation demonstrated the NPs presence in lungs tissues and this can be explained by assuming their ability to go into the blood stream and lately into the organs (generating inflammation).


Asunto(s)
Cerio/toxicidad , Inflamación/inducido químicamente , Nanopartículas del Metal/toxicidad , Animales , Análisis Químico de la Sangre , Cerio/administración & dosificación , Cerio/química , Índices de Eritrocitos , Femenino , Inflamación/sangre , Inflamación/patología , Riñón/efectos de los fármacos , Riñón/patología , Riñón/ultraestructura , Hígado/efectos de los fármacos , Hígado/patología , Hígado/ultraestructura , Pulmón/efectos de los fármacos , Pulmón/patología , Pulmón/ultraestructura , Macrófagos/efectos de los fármacos , Macrófagos/patología , Macrófagos/ultraestructura , Masculino , Nanopartículas del Metal/administración & dosificación , Nanopartículas del Metal/química , Nanopartículas del Metal/ultraestructura , Ratones , Ganglios Linfáticos Agregados/efectos de los fármacos , Ganglios Linfáticos Agregados/patología , Pruebas de Toxicidad/métodos , Toxicología
3.
Int J Mol Sci ; 14(2): 3065-77, 2013 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-23377016

RESUMEN

Owing to their radical scavenging and UV-filtering properties, ceria nanoparticles (CeO(2)-NPs) are currently used for various applications, including as catalysts in diesel particulate filters. Because of their ability to filter UV light, CeO(2)-NPs have garnered significant interest in the medical field and, consequently, are poised for use in various applications. The aim of this work was to investigate the effects of short-term (24 h) and long-term (10 days) CeO(2)-NP exposure to A549, CaCo2 and HepG2 cell lines. Cytotoxicity assays tested CeO(2)-NPs over a concentration range of 0.5 µg/mL to 5000 µg/mL, whereas genotoxicity assays tested CeO(2)-NPs over a concentration range of 0.5 µg/mL to 5000 µg/mL. In vitro assays showed almost no short-term exposure toxicity on any of the tested cell lines. Conversely, long-term CeO(2)-NP exposure proved toxic for all tested cell lines. NP genotoxicity was detectable even at 24-h exposure. HepG2 was the most sensitive cell line overall; however, the A549 line was most sensitive to the lowest concentration tested. Moreover, the results confirmed the ceria nanoparticles' capacity to protect cells when they are exposed to well-known oxidants such as H(2)O(2). A Comet assay was performed in the presence of both H(2)O(2) and CeO(2)-NPs. When hydrogen peroxide was maintained at 25 µM, NPs at 0.5 µg/mL, 50 µg/mL, and 500 µg/mL protected the cells from oxidative damage. Thus, the NPs prevented H(2)O(2)-induced genotoxic damage.

4.
Nanotoxicology ; 7(2): 221-33, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22279961

RESUMEN

In this work we investigated the toxicological effects of nude and chemically functionalised (-NH(2), -OH and -COOH groups) multiwall carbon nanotubes (mwCNTs) using immortalised mouse fibroblasts cell line (Balb/3T3) as in vitro model, alternative to the use of animals, to assess basal cytotoxicity, carcinogenic potential, genotoxicity and cell interaction of nanomaterials (NM). Combining in vitro tests such as cell transformation assay and micronucleus with physicochemical and topological analysis, we obtained results showing no cytotoxicity and genotoxicity. Carcinogenic potential and mwCNTs interaction with cells were instead evident. We stressed the importance that different toxicological end points have to be considered when studying NM, therefore, assays able to detect long-term effects, such as carcinogenicity, must be taken into account together with a panel of tests able to detect more immediate effects like basal cytotoxicity or genotoxicity.


Asunto(s)
Carcinógenos/toxicidad , Forma de la Célula/efectos de los fármacos , Transformación Celular Neoplásica/inducido químicamente , Nanotubos de Carbono/toxicidad , Alternativas a las Pruebas en Animales , Animales , Células 3T3 BALB , Pruebas de Carcinogenicidad , Transformación Celular Neoplásica/patología , Relación Dosis-Respuesta a Droga , Ratones , Micronúcleos con Defecto Cromosómico/inducido químicamente , Pruebas de Micronúcleos , Medición de Riesgo , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA