Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Clin Oral Investig ; 24(6): 1929-1938, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31515700

RESUMEN

OBJECTIVES: The study evaluates the influence of two spacer settings and three resin luting materials on the marginal and internal fit of polymer-infiltrated ceramic network (PICN) material crowns manufactured using a complete digital workflow. METHODS: Optical impressions of fifty identical dies were performed using the 3M scanner (software version 5.0.2). Twenty crowns were designed using Ceramill Mind (version 3.4.10.1163), from which ten with spacer setting of 50 µm (G1) and ten with 80 µm (G2). Thirty crowns (spacer setting of 50 µm) were divided into three groups corresponding to the resin materials used as follows: RelyX Unicem (RX), Variolink Esthetic (VLE), and Nexus 3 (NX3). All crowns were milled from Vita Enamic blocks. After micro-CT scanning, absolute marginal discrepancy (AMD), internal gap (IG), total cement space volume (TCV), and marginal porosities (VP) were measured. RESULTS: Significant difference was detected on the VP between the RX and NX3 group (p = 0.033). The mean values of all parameters were the following: AMD (µm): G1 182.6, G2 253.7, RX 210.8, VLE 195.5, NX3 186.6; IG (µm): G1 215.6, G2 173.1, RX 171.1, VLE 198.6, NX3 203; TCV (mm3): G1 22.9, G2 20.49, RX 17.57, VLE 17.49, NX3 20.59; VP (mm3): G1 0.26, G2 0.34, RX 0.32, VLE 0.46, NX3 0.54. CONCLUSIONS: Fit of PICN material crowns was not significantly influenced by increasing the spacer settings and cementation with different resin materials. Additionally, RelyX Unicem showed significantly less porosities as compared with Nexus3. CLINICAL RELEVANCE: Both 50 µm and 80 µm virtual spacer settings can be suggested for the manufacture of PICN crowns when Ceramill Mind (version 3.4.10.1163) is used. Furthermore, a self-adhesive system can be recommended for the cementation.


Asunto(s)
Coronas , Porcelana Dental , Polímeros , Cerámica , Diseño Asistido por Computadora , Adaptación Marginal Dental , Diseño de Prótesis Dental , Estética Dental , Ensayo de Materiales , Cementos de Resina , Flujo de Trabajo
2.
Front Physiol ; 10: 919, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31543822

RESUMEN

The aim of this study was to evaluate the effect of bleaching agents containing different concentrations of hydrogen peroxide (HP) on color-change and on enamel-surface in bovine teeth. Furthermore the influence on cell viability and proliferation was investigated. Two hundred and forty teeth were randomly assigned into four groups (home bleaching ≤6%, in-office bleaching ≤6%, in-office bleaching > 6% HP, and control group). Bleaching was performed after artificial staining and the bleached index (BI) as well as the whiteness index (WI D ) was measured at several time points. Chemical analysis for HP concentrations and the pH of the bleaching products was done. Furthermore, enamel surfaces of randomly selected specimens were analyzed using scanning electron microscopy (SEM) and cytotoxicity of the tested bleaching products was evaluated in vitro using dental pulp cells (DPCs) and L929 cells. A statistically significant whitening effect was observed in almost all products. As expected all investigated products resulted in decreased cell viability, however, with different values of LC50 (median lethal concentration). SEM analysis showed an analog of enamel alterations with decreasing pH, increasing exposure time, and increasing HP concentration. Bleaching agents containing a low HP concentration are considered to be effective and to have less damaging effects on enamel and tested cells.

3.
BMC Oral Health ; 19(1): 51, 2019 03 28.
Artículo en Inglés | MEDLINE | ID: mdl-30922281

RESUMEN

BACKGROUND: In view of the increasing demand of adult orthodontics for esthetic purposes, adult treatment with brackets has become an important issue. One essential factor for the quality of such treatment is bracket bonding on ceramics. For testing the adhesive bond between the bracket and the ceramic surface it is important to consider the static or cyclic loading that goes along with it. METHODS: Metallic Brackets were adhesively fixed on zirconia ceramic blocks in a simulated leveling phase using two different primers (Monobond S and Monobond Etch & Prime). Half of the metallic brackets were activated using a 0.14-nickel titanium wire, while the other half remained non-activated. Shear bond testing (SBT) was performed after thermocycling. Furthermore the Adhesive Remnant Index (ARI) was analyzed. RESULTS: SBT resulted in significantly higher shear bond values when Monobond Etch & Prime was used compared to the use of Monobond S. Activation of the brackets did not show different results in comparison to the non-activated brackets. The ARI did not indicate cement remnants on the ceramic surface, regardless of the primer and the activation status. CONCLUSIONS: The use of Monobond Etch & Prime has great potential for the bonding of brackets on dental zirconia ceramics.


Asunto(s)
Cerámica , Recubrimiento Dental Adhesivo , Soportes Ortodóncicos , Adulto , Análisis del Estrés Dental , Estética Dental , Humanos , Ensayo de Materiales , Cementos de Resina , Resistencia al Corte , Propiedades de Superficie , Circonio
4.
J Prosthodont Res ; 63(1): 40-46, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29891419

RESUMEN

PURPOSE: Purpose of this study was to evaluate the accuracy of fit of cemented polymer infiltrated ceramic network (PICN) material crowns manufactured after digital and conventional impression techniques using micro computed tomography (CT). Furthermore to determine the cement space volume and porosities in the cement layer. METHODS: A molar typodont tooth was prepared for PICN material crowns and replicated thirty times. The dies were randomly divided into three groups of 10 specimens each according to the impression technique: 3M True Definition Scanner (TDS), cara TRIOS (Trios) and Impregum Penta Soft (Impregum). PICN material crowns were milled for each specimen from Vita Enamic blocks and cemented on their respective dies. The absolute marginal discrepancy (AMD), internal fit (IG), total cement space volume (TVC) and marginal porosities (VP) were measured using Micro-CT. RESULTS: Mean and standard deviations values in µm for the AMD were: TDS 140.1 (28.4); Trios 253.7 (56.8); Impregum 220.2 (101.1). IG values in µm: TDS 173.1 (27.7); Trios 222.2 (22.4); Impregum 211.6 (55.9). TVC in mm3: TDS 19.82 (2.9); Trios 23.67 (2.01); Impregum 23.77 (5.09). VP in mm3: TDS 0.38 (0.09); Trios 0.36 (0.10); Impregum 0.51 (0.31). CONCLUSIONS: TDS group showed significantly better marginal and internal fit than the Trios group. No difference of the parameters was detected between the Impregum and both digital groups which implies that the digital impression technique is suitable in the manufacturing process of PICN material crowns.


Asunto(s)
Cerámica , Diseño Asistido por Computadora , Coronas , Técnica de Impresión Dental , Materiales Dentales , Porcelana Dental , Diseño de Prótesis Dental/métodos , Polímeros , Ajuste de Prótesis/métodos , Microtomografía por Rayos X , Cementación , Imagenología Tridimensional
5.
Am J Dent ; 30(5): 243-247, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29178726

RESUMEN

PURPOSE: To determine the performance of a resin composite material specially developed for core build-ups in comparison with conventional restorative materials. METHODS: 90 roughened ceramic blocs were divided into three groups; one group (n=30) was used for the core build-up material (Gradia Core) and the other two groups (n=30, each) were used for two conventional restorative materials (Tetric EvoCeram, Compoglass F). After adhesive fixation, specimens of each material were subdivided in accordance with the storage conditions (thermocycling or water storage). Shear bond strength was measured and fracture behavior was analyzed. RESULTS: Gradia Core presented significantly higher shear bond strength values than the conventional restorative material Tetric EvoCeram, both after 24 hours water storage as well as after thermocycling. Compoglass F did not show any statistically significant differences compared to the other materials, independent of the storage condition. However, Compoglass F resulted in numerically higher shear bond values than Tetric EvoCeram, but lower shear bond values than Gradia Core. Within the same materials, no statistically significant differences occurred regarding the storage conditions. CLINICAL SIGNIFICANCE: The specific core build-up material provided stronger bonding properties when luted to feldspar ceramic than conventional restorative materials, making it a suitable supporting material when high-quality esthetic restorations are needed for restoring decayed, but vital teeth.


Asunto(s)
Recubrimiento Dental Adhesivo , Cementos Dentales , Cementos de Resina , Cerámica , Resinas Compuestas , Ensayo de Materiales , Resistencia al Corte , Estrés Mecánico , Propiedades de Superficie
6.
BMC Oral Health ; 16(1): 129, 2016 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-27931256

RESUMEN

BACKGROUND: Evaluation of the marginal fit of cemented zirconia copings manufactured after digital impression with Lava™ Chairside Oral Scanner in comparison to that of zirconia copings manufactured after conventional impressions with polyvinyl siloxane. METHODS: A prepared typodont tooth #36, was replicated 40 times with a vinyl silicone and precise model resin. The dies were randomly divided into two groups according to the impression taking technique. Digital impressions with Lava™ C.O.S. and conventional impressions were taken according to the group. Subsequently zirconia copings were manufactured and cemented on their respective dies with zinc oxide phosphate cement. After embedding in resin, mesio-distal section of each coping was performed with a diamond saw in order to obtain two slices. One half of the specimen was used for evaluation with an optical microscope (OM) and the other half for evaluation with a scanning electron microscope (SEM). Marginal gap (MG) and absolute marginal discrepancy (AMD) were measured mesial and distal on each slice. RESULTS: No significant difference of the marginal parameters between the digital and the conventional group was found. The mean values for MG in the digital group were 96.28 µm (+/-43.21 µm) measured with the OM and 99.26 µm (+/-48.73 µm) measured with the SEM, respectively. AMD mean values were 191.54 µm (+/-85.42 µm) measured with the optical microscope and 211.6 µm (+/-96.55 µm) with the SEM. For the conventional group the mean MG values were 94.84 µm (+/-50.77 µm) measured with the OM and 83.37 µm (+/-44.38 µm) measured with the SEM, respectively. AMD mean values were 158.60 µm (+/-69.14 µm) for the OM and 152.72 µm (+/-72.36) for the SEM. CONCLUSIONS: Copings manufactured after digital impression with Lava™ C.O.S. show comparable marginal parameters with the copings manufactured after conventional impression with polyvinyl syloxane. The mean MG values of both groups fit in the clinically acceptable range.


Asunto(s)
Técnica de Impresión Dental , Adaptación Marginal Dental , Circonio , Diseño Asistido por Computadora , Coronas , Diseño de Prótesis Dental , Humanos , Distribución Aleatoria
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA