Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
8.
Artículo en Inglés | MEDLINE | ID: mdl-38764195

RESUMEN

OBJECTIVE: to describe the normal features of the caudo-thalamic groove at antenatal brain ultrasound in a group of structurally normal fetuses at third trimester and to report a small series of cases with abnormal appearance of the caudothalamic groove at antenatal brain ultrasound. METHODS: This was an observational study conducted at two referral Fetal Medicine units. A non-consecutive cohort of pregnant women with a singleton non anomalous pregnancy were prospectively recruited and underwent 3D ultrasound of the fetal brain at 28-32 weeks. At offline analysis the ultrasound volumes were adjusted in the multiplanar mode according to a standardized methodology, until the caudothalamic groove was visible on the parasagittal plane. To evaluate the inter-observer agreement, two operators were independently asked to indicate if the caudothalamic groove was visible unilaterally or bilaterally on each volume. The digital archives of the two Centres were also retrospectively searched to retrieve cases with abnormal findings at the level of the caudothalamic groove at antenatal brain ultrasound which were postnatally confirmed. RESULTS: 180 non-consecutive cases fulfilling the inclusion criteria were prospectively included. At offline analysis of the 3D US volumes the caudo-thalamic groove was identified on the parasagittal plane by both operators at least unilaterally in 176 cases (97.8%) and bilaterally in 174 cases (96.6%). The K-coefficient for the agreement between the two independent operators in recognizing the caudo-thalamic groove was 0.89 and 0.83 on one and both hemispheres respectively. At the retrospective search of our archives 5 cases with abnormal appearance of the groove at antenatal brain ultrasound (2 haemorrhage and 3 cyst) were found. CONCLUSION: Our study has demonstrated that the caudo-thalamic groove is consistently seen among normal fetuses at third trimester submitted to multiplanar neurosonography and that abnormal findings at this level may be antenatally detected. This article is protected by copyright. All rights reserved.

12.
Ultrasound Obstet Gynecol ; 63(2): 251-257, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-37610831

RESUMEN

OBJECTIVES: To evaluate the relationship between the attitude of the fetal head quantified by means of the chin-to-chest angle (CCA) in fetuses in occiput posterior (OP) position at the beginning of the second stage of labor, and persistent OP position at birth. METHODS: This was a single-center, prospective observational study conducted at the University Hospital of Parma, Parma, Italy. We included singleton pregnancies at term with fetuses in the OP position at the beginning of the second stage of labor. The fetal head position, station by means of angle of progression and head-to-perineum distance, and attitude by means of CCA were assessed using transabdominal or transperineal ultrasound. The primary outcome was persistent OP position at birth. RESULTS: Between January and July 2022, 76 women were included in the study. There were 48 (63.2%) spontaneous rotations of the fetal head and spontaneous vaginal delivery occurred in all. Among the 28 (36.8%) fetuses that did not rotate spontaneously into an occiput anterior position, eight (28.6%) had a spontaneous vaginal delivery, while operative vaginal delivery and Cesarean delivery was performed in 11 (39.3%) and nine (32.1%) cases, respectively. Multivariable logistic regression analysis showed that the CCA (adjusted odds ratio (aOR), 2.15 (95% CI, 1.22-3.78); P = 0.008) and nulliparity (aOR, 0.20 (95% CI, 0.06-0.76); P = 0.02) were associated independently with persistent OP position at birth. Moreover, the CCA showed an area under the receiver-operating-characteristics curve of 0.69 (95% CI, 0.56-0.82); P = 0.005) for the prediction of persistent OP position. The optimal cut-off value of the CCA was 36.5°, and was associated with a sensitivity of 0.82 (95% CI, 0.63-0.94), specificity of 0.50 (95% CI, 0.35-0.65), positive predictive value of 0.49 (95% CI, 0.34-0.64), negative predictive value of 0.83 (95% CI, 0.64-0.94), positive likelihood ratio of 1.64 (95% CI, 1.18-2.29) and negative likelihood ratio of 0.36 (95% CI, 0.15-0.83). CONCLUSIONS: Our data show that, within a population of women with fetal OP position at the beginning of the second stage of labor, the sonographic fetal head attitude measured by means of the CCA might help in the identification of fetuses at risk of persistent OP position. Such findings can be useful for patient counseling when OP position is diagnosed at full cervical dilatation. Further studies should investigate if the CCA might select patients who may benefit from manual rotation of the fetal head. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Feto , Presentación en Trabajo de Parto , Recién Nacido , Embarazo , Femenino , Humanos , Estudios Prospectivos , Feto/diagnóstico por imagen , Segundo Periodo del Trabajo de Parto , Ultrasonografía Prenatal , Parto Obstétrico , Cabeza/diagnóstico por imagen
15.
Ultrasound Obstet Gynecol ; 62(3): 398-404, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37099497

RESUMEN

OBJECTIVES: To describe the appearance and size of the ganglionic eminence (GE) in normal fetuses on midtrimester three-dimensional (3D) neurosonography and to report on the association between GE alterations (cavitation or enlargement) and malformation of cortical development (MCD). METHODS: This was a prospective multicenter cohort study of normal fetuses and a retrospective analysis of pathological cases with MCD. From January 2022 to June 2022, patients attending our tertiary centers for an expert fetal brain scan were recruited for the purpose of the study. A 3D volume of the fetal head, starting from the sagittal plane, was acquired in apparently normal fetuses using a transabdominal or transvaginal approach. Stored volume datasets were then evaluated independently by two expert operators. Two measurements (longitudinal diameter and transverse diameter) of the GE in the coronal view were obtained twice by each operator. Intra- and interobserver measurement variation was calculated. Reference ranges for GE measurements were calculated in the normal population. A previously stored volume dataset of 60 cases with MCD was also analyzed independently by the two operators using the same method in order to assess if GE abnormalities (cavitation or enlargement) were present. Postnatal follow-up was obtained in all cases. RESULTS: In the study period, 160 normal fetuses between 19 and 22 weeks of gestation were included in the study. The GE was visible in the coronal plane on 3D neurosonography in 144 (90%) cases and was not clearly visible in the remaining 16 (10%) cases. The intra- and interobserver agreement was almost perfect for the longitudinal diameter, with an intraclass correlation coefficient (ICC) of 0.90 (95% CI, 0.83-0.93) and 0.90 (95% CI, 0.86-0.92), respectively, and substantial for the transverse diameter, with an ICC of 0.80 (95% CI, 0.70-0.87) and 0.64 (95% CI, 0.53-0.72), respectively. A retrospective analysis of 50 cases with MCD in the second trimester showed that GE enlargement was present in 12 cases and GE cavitation was present in four cases. CONCLUSIONS: Systematic assessment of the GE in fetuses at 19-22 weeks of gestation is feasible on 3D neurosonography, with good reproducibility in normal cases. Cavitation or enlargement of the GE can be demonstrated in fetuses with MCD. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Feto , Ultrasonografía Prenatal , Femenino , Embarazo , Humanos , Segundo Trimestre del Embarazo , Estudios Retrospectivos , Estudios Prospectivos , Reproducibilidad de los Resultados , Estudios de Cohortes , Ultrasonografía Prenatal/métodos , Feto/anomalías , Edad Gestacional
16.
Ultrasound Obstet Gynecol ; 62(2): 219-225, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36905679

RESUMEN

OBJECTIVE: The prediction of adverse perinatal outcomes in low-risk pregnancies is poor, mainly owing to the lack of reliable biomarkers. Uterine artery (UtA) Doppler is closely associated with placental function and may facilitate the peripartum detection of subclinical placental insufficiency. The objective of this study was to evaluate the association of mean UtA pulsatility index (PI) measured in early labor with obstetric intervention for suspected intrapartum fetal compromise and adverse perinatal outcome in uncomplicated singleton term pregnancies. METHODS: This was a prospective multicenter observational study conducted across four tertiary maternity units. Low-risk term pregnancies with spontaneous onset of labor were included. The mean UtA-PI was recorded between uterine contractions in women admitted for early labor and converted into multiples of the median (MoM). The primary outcome of the study was the occurrence of obstetric intervention, i.e. Cesarean section or instrumental delivery, for suspected intrapartum fetal compromise. Secondary outcomes were the occurrence of adverse perinatal outcomes, including 5-min Apgar score < 7, low cord arterial pH, raised cord arterial base excess, admission to the neonatal intensive care unit (NICU) and postnatal diagnosis of small-for-gestational-age fetus. Composite adverse perinatal outcome was defined as the occurrence of at least one of the following: acidemia in the umbilical artery, defined as pH < 7.10 and/or base excess > 12 mmol/L, 5-min Apgar score < 7 or admission to the NICU. RESULTS: Overall, 804 women were included, of whom 40 (5.0%) had abnormal mean UtA-PI MoM. Women who had an obstetric intervention for suspected intrapartum fetal compromise were more frequently nulliparous (72.2% vs 53.6%; P = 0.008), had a higher frequency of increased mean UtA-PI MoM (13.0% vs 4.4%; P = 0.005) and had a longer duration of labor (456 ± 221 vs 371 ± 192 min; P = 0.01). On logistic regression analysis, only increased mean UtA-PI MoM (adjusted odds ratio (aOR), 3.48 (95% CI, 1.43-8.47); P = 0.006) and parity (aOR, 0.45 (95% CI, 0.24-0.86); P = 0.015) were independently associated with obstetric intervention for suspected intrapartum fetal compromise. Increased mean UtA-PI MoM was associated with a sensitivity of 0.13 (95% CI, 0.05-0.25), specificity of 0.96 (95% CI, 0.94-0.97), positive predictive value of 0.18 (95% CI, 0.07-0.33), negative predictive value of 0.94 (95% CI, 0.92-0.95), positive likelihood ratio of 2.95 (95% CI, 1.37-6.35) and negative likelihood ratio of 0.91 (95% CI, 0.82-1.01) for obstetric intervention for suspected intrapartum fetal compromise. Pregnancies with increased mean UtA-PI MoM also showed a higher incidence of birth weight < 10th percentile (20.0% vs 6.7%; P = 0.002), NICU admission (7.5% vs 1.2%; P = 0.001) and composite adverse perinatal outcome (15.0% vs 5.1%; P = 0.008). CONCLUSION: Our study, conducted in a cohort of low-risk term pregnancies enrolled in early spontaneous labor, showed an independent association between increased mean UtA-PI and obstetric intervention for suspected intrapartum fetal compromise, albeit with moderate capacity to rule in, and poor capacity to rule out, this condition. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Cesárea , Resultado del Embarazo , Recién Nacido , Embarazo , Femenino , Humanos , Resultado del Embarazo/epidemiología , Tercer Trimestre del Embarazo , Arteria Uterina/diagnóstico por imagen , Estudios Prospectivos , Placenta/irrigación sanguínea , Ultrasonografía Doppler , Ultrasonografía Prenatal , Flujo Pulsátil , Arterias Umbilicales/diagnóstico por imagen
17.
J Matern Fetal Neonatal Med ; 36(1): 2184221, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36935360

RESUMEN

INTRODUCTION: The European Society of Cardiology (ESC) guidelines (GL) provide indications on the mode of delivery in women with heart disease. However available data suggests that the rate of Cesarean Delivery (CD) is high and widely variable among such patients. In this study, we aimed to investigate the degree of adherence to the ESC recommendations among women delivering in four tertiary maternity services in Italy and how this affects the maternal and neonatal outcomes. MATERIAL AND METHODS: Retrospective multicenter cohort study including pregnant women with heart disease who gave birth between January 2014 and July 2020. Composite adverse maternal outcome (CAM) was defined by the occurrence of one or more of the following: major postpartum hemorrhage, thrombo-embolic or ischemic event, de novo arrhythmia, heart failure, endocarditis, aortic dissection, need for re-surgery, sepsis, maternal death. Composite Adverse Neonatal outcome (CAN) was defined as cord arterial pH <7.00, APGAR <7 at 5 min, admission to the intensive care unit, and neonatal death. We compared the incidence of CAM and CAN between the cases with planned delivery in accordance (group "ESC consistent") or in disagreement (group "ESC not consistent") with the ESC GL. RESULTS: Overall, 175 women and 181 liveborn were included. A higher frequency of CAN was found when delivery was not planned accordingly to the ESC guidelines [("ESC consistent" 9/124 (7.2%) vs "ESC not consistent" 13/57 (22.8%) p = 0.002 OR 3.74 (CI 95% 1.49-9.74) , while the occurrence of CAM was comparable between the two groups. At logistic regression analysis, the gestational age at delivery was the only parameter independently associated with the occurrence of CAN (p = 0.006). CONCLUSION: Among pregnant women with heart disease, deviating from the ESC guidelines scheduling cesarean delivery does not seem to improve maternal outcomes and it is associated with worse perinatal outcomes, mainly due to lower gestational age at birth.


Asunto(s)
Cardiología , Cardiopatías , Recién Nacido , Femenino , Embarazo , Humanos , Estudios de Cohortes , Periodo Periparto , Cesárea
19.
Ultrasound Obstet Gynecol ; 61(1): 93-98, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35767709

RESUMEN

OBJECTIVE: To evaluate the relationship between the fetal head-circumference-to-maternal-height (HC/MH) ratio measured shortly before delivery and the occurrence of Cesarean section (CS) for labor dystocia. METHODS: This was a multicenter prospective cohort study involving four tertiary maternity hospitals. An unselected cohort of women with a singleton fetus in cephalic presentation, at a gestational age beyond 36 + 0 weeks and without any contraindication for vaginal delivery, was enrolled between September 2020 and November 2021. The MH and fetal HC were measured on admission of the patient to the labor ward. The primary outcome of the study was the performance of the HC/MH ratio in the prediction of CS for labor dystocia. Women who underwent CS for any indication other than failed labor progression, including fetal distress, were excluded from the final analysis. RESULTS: A total of 783 women were included in the study. Vaginal delivery occurred in 744 (95.0%) women and CS for labor dystocia in 39 (5.0%). CS for labor dystocia was associated with shorter MH (mean ± SD, 160.4 ± 6.6 vs 164.5 ± 6.3 cm; P < 0.001), larger fetal HC (339.6 ± 9.5 vs 330.7 ± 13.0 mm; P < 0.001) and a higher HC/MH ratio (2.12 ± 0.11 vs 2.01 ± 0.10; P < 0.001) compared with vaginal delivery. Multivariate logistic regression analysis showed that the HC/MH ratio was associated independently with CS for labor dystocia (adjusted odds ratio, 2.65 (95% CI, 1.85-3.79); P < 0.001). The HC/MH ratio had an area under the receiver-operating-characteristics curve of 0.77 and an optimal cut-off value for discriminating between vaginal delivery and CS for labor dystocia of 2.09, which was associated with a sensitivity of 0.62 (95% CI, 0.45-0.77), specificity of 0.79 (95% CI, 0.76-0.82), positive predictive value of 0.13 (95% CI, 0.09-0.19) and negative predictive value of 0.98 (95% CI, 0.96-0.99). CONCLUSIONS: In a large cohort of unselected pregnancies, the HC/MH ratio performed better than did fetal HC and MH alone in identifying those cases that will undergo CS for labor dystocia, albeit with moderate predictive value. The HC/MH ratio could assist in the evaluation of women at risk for CS for labor dystocia. © 2022 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Distocia , Trabajo de Parto , Embarazo , Femenino , Humanos , Lactante , Masculino , Cesárea , Estudios Prospectivos , Ultrasonografía Prenatal
20.
Ultrasound Obstet Gynecol ; 60(5): 708-709, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36318628
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA