Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Sci Robot ; 9(94): eadp3260, 2024 Sep 11.
Artículo en Inglés | MEDLINE | ID: mdl-39259781

RESUMEN

The loss of a hand disrupts the sophisticated neural pathways between the brain and the hand, severely affecting the level of independence of the patient and the ability to carry out daily work and social activities. Recent years have witnessed a rapid evolution of surgical techniques and technologies aimed at restoring dexterous motor functions akin to those of the human hand through bionic solutions, mainly relying on probing of electrical signals from the residual nerves and muscles. Here, we report the clinical implementation of an interface aimed at achieving this goal by exploiting muscle deformation, sensed through passive magnetic implants: the myokinetic interface. One participant with a transradial amputation received an implantation of six permanent magnets in three muscles of the residual limb. A truly self-contained myokinetic prosthetic arm embedding all hardware components and the battery within the prosthetic socket was developed. By retrieving muscle deformation caused by voluntary contraction through magnet localization, we were able to control in real time a dexterous robotic hand following both a direct control strategy and a pattern recognition approach. In just 6 weeks, the participant successfully completed a series of functional tests, achieving scores similar to those achieved when using myoelectric controllers, a standard-of-care solution, with comparable physical and mental workloads. This experience raised conceptual and technical limits of the interface, which nevertheless pave the way for further investigations in a partially unexplored field. This study also demonstrates a viable possibility for intuitively interfacing humans with robotic technologies.


Asunto(s)
Amputados , Miembros Artificiales , Fuerza de la Mano , Imanes , Diseño de Prótesis , Robótica , Humanos , Amputados/rehabilitación , Fuerza de la Mano/fisiología , Robótica/instrumentación , Masculino , Músculo Esquelético/fisiología , Extremidad Superior , Mano/fisiología , Adulto , Electromiografía , Muñones de Amputación/fisiopatología , Contracción Muscular/fisiología , Implantación de Prótesis
2.
Sci Robot ; 8(83): eadf7360, 2023 10 18.
Artículo en Inglés | MEDLINE | ID: mdl-37820004

RESUMEN

Restoration of sensorimotor function after amputation has remained challenging because of the lack of human-machine interfaces that provide reliable control, feedback, and attachment. Here, we present the clinical implementation of a transradial neuromusculoskeletal prosthesis-a bionic hand connected directly to the user's nervous and skeletal systems. In one person with unilateral below-elbow amputation, titanium implants were placed intramedullary in the radius and ulna bones, and electromuscular constructs were created surgically by transferring the severed nerves to free muscle grafts. The native muscles, free muscle grafts, and ulnar nerve were implanted with electrodes. Percutaneous extensions from the titanium implants provided direct skeletal attachment and bidirectional communication between the implanted electrodes and a prosthetic hand. Operation of the bionic hand in daily life resulted in improved prosthetic function, reduced postamputation, and increased quality of life. Sensations elicited via direct neural stimulation were consistently perceived on the phantom hand throughout the study. To date, the patient continues using the prosthesis in daily life. The functionality of conventional artificial limbs is hindered by discomfort and limited and unreliable control. Neuromusculoskeletal interfaces can overcome these hurdles and provide the means for the everyday use of a prosthesis with reliable neural control fixated into the skeleton.


Asunto(s)
Calidad de Vida , Robótica , Humanos , Retroalimentación , Biónica , Titanio , Retroalimentación Sensorial/fisiología , Electrodos Implantados
3.
Artículo en Inglés | MEDLINE | ID: mdl-36327175

RESUMEN

The design of prosthetic controllers by means of neurophysiological signals still poses a crucial challenge to bioengineers. State of the art of electromyographic (EMG) continuous pattern recognition controllers rely on the questionable assumption that repeated muscular contractions produce repeatable patterns of steady-state EMG signals. Conversely, we propose an algorithm that decodes wrist and hand movements by processing the signals that immediately follow the onset of contraction (i.e., the transient EMG). We collected EMG data from the forearms of 14 non-amputee and 5 transradial amputee participants while they performed wrist flexion/extension, pronation/supination, and four hand grasps (power, lateral, bi-digital, open). We firstly identified the combination of wrist and hand movements that yielded the best control performance for the same participant (intra-subject classification). Then, we assessed the ability of our algorithm to classify participant data that were not included in the training set (cross-subject classification). Our controller achieved a median accuracy of ~96% with non-amputees, while it achieved heterogeneous outcomes with amputees, with a median accuracy of ~89%. Importantly, for each amputee, it produced at least one acceptable combination of wrist-hand movements (i.e., with accuracy >85%). Regarding the cross-subject classifier, while our algorithm obtained promising results with non-amputees (accuracy up to ~80%), they were not as good with amputees (accuracy up to ~35%), possibly suggesting further assessments with domain-adaptation strategies. In general, our offline outcomes, together with a preliminary online assessment, support the hypothesis that the transient EMG decoding could represent a viable pattern recognition strategy, encouraging further online assessments.


Asunto(s)
Miembros Artificiales , Muñeca , Humanos , Muñeca/fisiología , Electromiografía/métodos , Mano/fisiología , Articulación de la Muñeca , Algoritmos , Movimiento/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA