RESUMEN
The expression of prostate-specific membrane antigen (PSMA) is upregulated in prostate cancer (PCa) cells and PSMA-ligands have been radiolabeled and used as radiopharmaceuticals for targeted radionuclide therapy (TRT), single photon emission computed tomography (SPECT) or positron emission tomography (PET) molecular imaging, and radioguided surgery in PCa patients. Herein, we aimed at radiolabeling the PSMA-I&S cold kit with 99mTc, resulting in a radiopharmaceutical with high radiochemical yield (RCY) and stability for SPECT imaging and radioguided surgery in PCa malignancies. Various pre-clinical assays were conducted to evaluate the [99mTc]Tc-PSMA-I&S obtained by the cold kit. These assays included assessments of RCY, radiochemical stability in saline, lipophilicity, serum protein binding (SPB), affinity for LNCaP-PCa cells (binding and internalization studies), and ex vivo biodistribution profile in naive and LNCaP-PCa-bearing mice. The radiopharmaceutical was obtained with good RCY (92.05% ± 2.20%) and remained stable for 6 h. The lipophilicity was determined to be -2.41 ± 0.06, while the SPB was â¼97%. The binding percentages to LNCaP cells were 9.41% ± 0.57% (1 h) and 10.45% ± 0.45% (4 h), with 63.12 ± 0.93 (1 h) and 65.72% ± 1.28% (4 h) of the bound material being internalized. Blocking assays, employing an excess of unlabeled PSMA-I&S, resulted in a reduction in the binding percentage by 2.6 times. The ex vivo biodistribution profile confirmed high accumulation of [99mTc]Tc-PSMA-I&S in the tumor and the tumor-to-contralateral muscle ratio was â¼6.5. In conclusion, [99mTc]Tc-PSMA-I&S was successfully obtained by radiolabeling the cold kit using freshly eluted [99mTc]NaTcO4, exhibiting good RCY and radiochemical stability. The preclinical assays demonstrated that the radiopharmaceutical shows favorable characteristics for SPECT imaging and radioguided surgery in PCa patients.
RESUMEN
OBJECTIVE: To evaluate the predictive value of positron emission computed tomography or magnetic resonance (PET-CT and PET-MRI) using gallium-68-labeled prostate-specific membrane antigen (68Ga-PSMA) in lymph node involvement in prostate cancer. METHODS: A retrospective study comprising 91 patients diagnosed with prostate cancer between 2016 to 2020, who underwent 68Ga-PSMA PET-CT or PET-MRI for staging before prostatectomy. The patients were divided into Group 1, with 65 patients with satisfactory pathological lymph node analysis, and Group 2, with 91 patients representing the sum of patients with pathological lymph node analysis and those with postoperative prostate-specific antigen within 60 days after surgery. Receiver Operating Characteristic curves were used to assess accuracy of predictive capacity of imaging exams for lymph node involvement. RESULTS: Regarding local clinical staging, the groups showed similar results, and 50% were classified as staging T2a. The accuracy of 68Ga-PSMA PET-CT for prostate cancer lymph node staging was 86.5% (95%CI 0.74-0.94; p=0.06), with a sensitivity of 58.3% and specificity of 95%. The accuracy of 68Ga-PSMA PET-MRI was 84.6% (95%CI 0.69-0.94; p=0.09), with a sensitivity of 40% and specificity of 100%. Considering both 68Ga-PSMA PET-CT and PET-MRI, the accuracy was 85.7% (95%CI 0.76-0.92; p=0.015), with sensitivity of 50% and specificity of 97%. CONCLUSION: The imaging tests 68Ga-PSMA PET-CT and PET-MRI were highly accurate to detect preoperative lymph node involvement, and could be useful tools to indicate the need for extended lymph node dissection during radical prostatectomy.
Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Neoplasias de la Próstata , Isótopos de Galio , Radioisótopos de Galio , Humanos , Ganglios Linfáticos/patología , Metástasis Linfática/diagnóstico por imagen , Metástasis Linfática/patología , Imagen por Resonancia Magnética , Masculino , Estadificación de Neoplasias , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía de Emisión de Positrones , Prostatectomía , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/cirugía , Estudios RetrospectivosRESUMEN
ABSTRACT Objective To evaluate the predictive value of positron emission computed tomography or magnetic resonance (PET-CT and PET-MRI) using gallium-68-labeled prostate-specific membrane antigen (68Ga-PSMA) in lymph node involvement in prostate cancer. Methods A retrospective study comprising 91 patients diagnosed with prostate cancer between 2016 to 2020, who underwent 68Ga-PSMA PET-CT or PET-MRI for staging before prostatectomy. The patients were divided into Group 1, with 65 patients with satisfactory pathological lymph node analysis, and Group 2, with 91 patients representing the sum of patients with pathological lymph node analysis and those with postoperative prostate-specific antigen within 60 days after surgery. Receiver Operating Characteristic curves were used to assess accuracy of predictive capacity of imaging exams for lymph node involvement. Results Regarding local clinical staging, the groups showed similar results, and 50% were classified as staging T2a. The accuracy of 68Ga-PSMA PET-CT for prostate cancer lymph node staging was 86.5% (95%CI 0.74-0.94; p=0.06), with a sensitivity of 58.3% and specificity of 95%. The accuracy of 68Ga-PSMA PET-MRI was 84.6% (95%CI 0.69-0.94; p=0.09), with a sensitivity of 40% and specificity of 100%. Considering both 68Ga-PSMA PET-CT and PET-MRI, the accuracy was 85.7% (95%CI 0.76-0.92; p=0.015), with sensitivity of 50% and specificity of 97%. Conclusion The imaging tests 68Ga-PSMA PET-CT and PET-MRI were highly accurate to detect preoperative lymph node involvement, and could be useful tools to indicate the need for extended lymph node dissection during radical prostatectomy.
RESUMEN
PURPOSE: To evaluate the performance of [68Ga]Ga-PSMA-11 PET/CT in the diagnosis of recurrent prostate cancer (PC) after prostatectomy in a large multicentre cohort. METHODS: The centres, which contributed to this study, were the departments of nuclear medicine of Heidelberg (Germany), Technical University of Munich (Germany) and Albert Einstein Hospital of São Paulo (Brazil). A total of 2533 patients who were scanned with [68Ga]Ga-PSMA-11 PET/CT at 1 h p.i. due to recurrent PC after prostatectomy were included in this retrospective analysis. Exclusion criteria were as follows: patients with untreated primary tumour, previous chemotherapy or Xofigo®; those previously treated with exclusively external beam radiation therapy or HIFU; those referred for PSMA-therapy; and those treated with ADT (including first- and second-generation ADT) within the last 6 months. Potential influences of different factors such as PSA level, PSA doubling-time (PSADT), PSA velocity (PSAVel), Gleason Score (GSC, including the separate analysis of 7a and 7b), age and amount of injected tracer were evaluated in a multivariable analysis. RESULTS: The rate of pathologic PET/CT-scans was 43% for PSA ≤ 0.2 ng/ml, 58% for PSA > 0.2 to ≤ 0.5, 72% for PSA > 0.5 to ≤ 1.0 and increased to a maximum of 93% for PSA > 10 ng/ml. A pathological PET/CT was significantly (p = 0.001) associated with PSA level and higher GSC. Amount of injected tracer, age, PSADT and PSAVel were not associated with a higher probability of a pathological scan. CONCLUSION: [68Ga]Ga-PSMA-11 PET/CT at 1 h p.i. confirmed its high performance in the largest patient cohort yet analysed. Tumour detection showed a clear association with higher PSA and higher GSC. No association was found between a pathological [68Ga]Ga-PSMA-11 PET/CT and age, amount of injected tracer, PSADT or PSAVel.
Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Neoplasias de la Próstata , Brasil , Ácido Edético , Radioisótopos de Galio , Alemania , Humanos , Masculino , Recurrencia Local de Neoplasia/diagnóstico por imagen , Antígeno Prostático Específico , Prostatectomía , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/cirugía , Estudios RetrospectivosAsunto(s)
Compuestos Organometálicos , Neoplasias de la Próstata , Ácido Edético/análogos & derivados , Isótopos de Galio , Radioisótopos de Galio , Humanos , Masculino , Glicoproteínas de Membrana , Oligopéptidos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Neoplasias de la Próstata/diagnóstico por imagenRESUMEN
BACKGROUND: The positron emission tomography (PET) ligand 68Ga-Glu-urea-Lys(Ahx)-HBED-CC (68Ga-PSMA-11) targets the prostate-specific membrane antigen (PSMA), upregulated in prostate cancer cells. Although 68Ga-PSMA-11 PET is widely used in research and clinical practice, full kinetic modeling has not yet been reported nor have simplified methods for quantification been validated. The aims of our study were to quantify 68Ga-PSMA-11 uptake in primary prostate cancer patients using compartmental modeling with arterial blood sampling and to validate the use of standardized uptake values (SUV) and image-derived blood for quantification. RESULTS: Fifteen patients with histologically proven primary prostate cancer underwent a 60-min dynamic 68Ga-PSMA-11 PET scan of the pelvis with axial T1 Dixon, T2, and diffusion-weighted magnetic resonance (MR) images acquired simultaneously. Time-activity curves were derived from volumes of interest in lesions, normal prostate, and muscle, and mean SUV calculated. In total, 18 positive lesions were identified on both PET and MR. Arterial blood activity was measured by automatic arterial blood sampling and manual blood samples were collected for plasma-to-blood ratio correction and for metabolite analysis. The analysis showed that 68Ga-PSMA-11 was stable in vivo. Based on the Akaike information criterion, 68Ga-PSMA-11 kinetics were best described by an irreversible two-tissue compartment model. The rate constants K1 and k3 and the net influx rate constants Ki were all significantly higher in lesions compared to normal tissue (p < 0.05). Ki derived using image-derived blood from an MR-guided method showed excellent agreement with Ki derived using arterial blood sampling (intraclass correlation coefficient = 0.99). SUV correlated significantly with Ki with the strongest correlation of scan time-window 30-45 min (rho 0.95, p < 0.001). Both Ki and SUV correlated significantly with serum prostate specific antigen (PSA) level and PSA density. CONCLUSIONS: 68Ga-PSMA-11 kinetics can be described by an irreversible two-tissue compartment model. An MR-guided method for image-derived blood provides a non-invasive alternative to blood sampling for kinetic modeling studies. SUV showed strong correlation with Ki and can be used in routine clinical settings to quantify 68Ga-PSMA-11 uptake.
RESUMEN
OBJECTIVE: Positron emission tomography in association with magnetic resonance imaging (PET/MR) and 68Ga-PSMA-11 has shown superior detection in recurrent prostate cancer patients as compared to PET/computed tomography (PET/CT). There are, however, several technological differences between PET/CT and PET/MR systems which affect the PET image quality. The objective of this study was to assess the reproducibility of PET/CT and PET/MR SUV's in recurrent prostate cancer patients. We randomized the patients regarding the order of the PET/CT and PET/MR scans to reduce the influence of tracer uptake as a function of time. METHODS: Thirty patients, all with biochemical recurrence after radical prostatectomy, underwent whole-body PET/CT and PET/MR scans after intravenous injection of a single dose of 68Ga-PSMA-11. Fifteen patients underwent PET/CT first and 15 patients underwent PET/MR first. Volumes of interest on tumor lesions were outlined and maximum standardized uptake value (SUVmax) corrected for lean body mass was calculated. Correlation and agreement between scans were assessed by generalized linear mixed-effects models and Bland-Altman analysis. The association between SUV, patient characteristics and imaging parameters was assessed. RESULTS: Eighteen of the 30 evaluated patients had at least one positive lesion, giving an overall detection rate of 60%. In total, there were 34 visible lesions: 5 local recurrences, 22 lymph node metastases and 7 bone metastases. One group acquired PET/CT and PET/MR at median time points of 63.0 and 159.0 min, while the other group acquired PET/MR and PET/CT at median time points of 92.0 and 149.0 min. SUVmax between scans was linearly correlated, described by the equation Y(PET/CT SUVmax) = 0.75 + 1.00 × (PET/MR SUVmax), on average 20% higher on PET/CT than on PET/MR. SUV associated significantly only with type of lesion, scan time post-injection and acquisition time per bed position. CONCLUSIONS: SUVmax from PET/CT and PET/MR are linearly correlated, on average 20% higher on PET/CT than on PET/MR and should, therefore, not be used interchangeably in patient follow-up.
Asunto(s)
Ácido Edético/análogos & derivados , Imagen por Resonancia Magnética/normas , Oligopéptidos/metabolismo , Tomografía Computarizada por Tomografía de Emisión de Positrones/normas , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/metabolismo , Anciano , Transporte Biológico , Ácido Edético/metabolismo , Isótopos de Galio , Radioisótopos de Galio , Humanos , Masculino , Recurrencia , Estándares de Referencia , Reproducibilidad de los Resultados , Factores de TiempoAsunto(s)
Adenocarcinoma/secundario , Tomografía Computarizada por Tomografía de Emisión de Positrones , Neoplasias de la Próstata/patología , Neoplasias Testiculares/secundario , Adenocarcinoma/diagnóstico por imagen , Anciano , Humanos , Masculino , Antígeno Prostático Específico , Prostatectomía , Neoplasias Testiculares/diagnóstico por imagenRESUMEN
In recent years, medical imaging with hybrid techniques has widely accepted and employed in clinical routine. PET/MRI offers significant advantages, including excellent contrast and resolution and reduced ionizing radiation, as compared to well-established PET/CT. Therefore, PET/MRI is a promising modality for oncologic imaging of some regions, such as brain, head and neck, liver and pelvis. This article set out to analyze clinical conditions that could benefit from PET/MRI imaging based on our caseload. The potential of PET/MRI to become the imaging modality of choice for assessment of neurologic and oncologic conditions associated with soft tissues is highlighted. Clinical aspects of PET/MRI and its application to clinical cases are illustrated with examples extracted from the authors' preliminary experience. RESUMO Nos últimos anos, imagens médicas com tecnologias híbridas tornaram-se amplamente aceitas e utilizadas na prática clínica. O PET/RM possui vantagens importantes, incluindo excelentes contrastes e resolução, e menor radiação ionizante, em comparação ao PET/TC. Por isto, é uma modalidade promissora para exames de imagem de pacientes oncológicos, para avaliar o cérebro, cabeça e pescoço, o fígado e a pelve. O objetivo deste artigo foi analisar as situações clínicas que se beneficiariam de exames de PET/RM a partir de uma casuística. Destacamos o potencial desta técnica se tornar o método de imagem de escolha para doenças neurológicas e oncológicas que envolvam partes moles. Os aspectos clínicos de PET/RM e sua aplicação aos casos clínicos são ilustrados com exemplos da experiência inicial dos autores.
Asunto(s)
Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Imagen Multimodal/métodos , Mieloma Múltiple/diagnóstico por imagen , Enfermedad de Parkinson/diagnóstico por imagen , Neoplasias Pélvicas/diagnóstico por imagen , Tomografía de Emisión de Positrones/métodos , Adenocarcinoma/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Brasil , Carcinoma/diagnóstico por imagen , Femenino , Humanos , Ganglios Linfáticos/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Neuroimagen/métodos , Reproducibilidad de los ResultadosRESUMEN
ABSTRACT In recent years, medical imaging with hybrid techniques has widely accepted and employed in clinical routine. PET/MRI offers significant advantages, including excellent contrast and resolution and reduced ionizing radiation, as compared to well-established PET/CT. Therefore, PET/MRI is a promising modality for oncologic imaging of some regions, such as brain, head and neck, liver and pelvis. This article set out to analyze clinical conditions that could benefit from PET/MRI imaging based on our caseload. The potential of PET/MRI to become the imaging modality of choice for assessment of neurologic and oncologic conditions associated with soft tissues is highlighted. Clinical aspects of PET/MRI and its application to clinical cases are illustrated with examples extracted from the authors’ preliminary experience.
RESUMO Nos últimos anos, imagens médicas com tecnologias híbridas tornaram-se amplamente aceitas e utilizadas na prática clínica. O PET/RM possui vantagens importantes, incluindo excelentes contrastes e resolução, e menor radiação ionizante, em comparação ao PET/TC. Por isto, é uma modalidade promissora para exames de imagem de pacientes oncológicos, para avaliar o cérebro, cabeça e pescoço, o fígado e a pelve. O objetivo deste artigo foi analisar as situações clínicas que se beneficiariam de exames de PET/RM a partir de uma casuística. Destacamos o potencial desta técnica se tornar o método de imagem de escolha para doenças neurológicas e oncológicas que envolvam partes moles. Os aspectos clínicos de PET/RM e sua aplicação aos casos clínicos são ilustrados com exemplos da experiência inicial dos autores.
Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Enfermedad de Parkinson/diagnóstico por imagen , Neoplasias Pélvicas/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Tomografía de Emisión de Positrones/métodos , Imagen Multimodal/métodos , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Mieloma Múltiple/diagnóstico por imagen , Brasil , Carcinoma/diagnóstico por imagen , Adenocarcinoma/diagnóstico por imagen , Reproducibilidad de los Resultados , Neuroimagen/métodos , Ganglios Linfáticos/diagnóstico por imagenRESUMEN
OBJECTIVE: The aim of this study was to assess the occurrence and frequency of increased physiologic uptake of 99mTc-HYNIC-TOC by the uncinate process of the pancreas in SPECT/CT images. METHODS: Forty-six scans of 41 patients were evaluated retrospectively. The uptake of 99mTc-HYNIC-TOC was considered to be physiologic in patients with normal findings at dedicated abdominal CT or MR and lack of neoplastic lesions in clinical follow-ups. The intensity of uncinate process uptake was compared to the uptake of the normal liver. RESULTS: Focal uptake was attributed to the presence of pancreatic NET in 5 patients. Among the 36 patients without any evidence of malignancy in CT, MR and follow-up, 7 (19.4 %) showed increased uptake in the uncinate process. The intensity of uptake was lesser in 3 (8.3 %), similar in 3 and greater than the normal liver in 1 (2.8 %) case. CONCLUSION: Increased 99mTc-HYNIC-TOC uptake occurred in 19.4 % of those subjects without any evidence of neuroendocrine tumor in the uncinate process.
Asunto(s)
Imagen Multimodal , Octreótido/análogos & derivados , Compuestos de Organotecnecio/farmacocinética , Páncreas/metabolismo , Radiofármacos/farmacocinética , Tomografía Computarizada de Emisión de Fotón Único , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Hígado/metabolismo , Masculino , Persona de Mediana Edad , Tumores Neuroendocrinos/diagnóstico , Octreótido/farmacocinética , Receptores de Somatostatina , Estudios RetrospectivosRESUMEN
The authors report the case of a 70-year-old male patient with chronic lymphoid leukemia who presented subsequently a papillary carcinoma of the thyroid with metastases to regional lymph nodes. The patient was treated with surgical thyroidectomy with regional and cervical lymph node excision and radioiodine therapy (I-131). The protocolar control scintigraphy 4 days after the radioactive dose showed I-131 uptake in both axillae and even in the inguinal regions. PET/CT showed faint FDG-F-18 uptake in one lymph node of the left axilla. An ultrasound guided fine needle biopsy of this lymph node identified by I-131 SPECT/CT and FDG-F-18 PET/CT revealed lymphoma cells and was negative for thyroid tissue and thyroglobulin content. The sequential blood counts done routinely after radiation treatment showed a marked fall until return to normal values of leucocytes and lymphocytes (absolute and relative), which were still normal in the last control 19 months after the radioiodine administration. Chest computed tomography showed a decrease in size of axillary and para-aortic lymph nodes. By immunohistochemistry, cells of the lymphoid B lineage decreased from 52% before radioiodine therapy to 5% after the procedure. The authors speculate about a possible sodium iodide symporter expression by the cells of this lymphoma, similar to some other non-thyroid tumors, such as breast cancer cells.
Asunto(s)
Carcinoma/radioterapia , Carcinoma/secundario , Terapia por Láser/métodos , Leucemia Linfocítica Crónica de Células B/radioterapia , Neoplasias de la Tiroides/radioterapia , Neoplasias de la Tiroides/secundario , Anciano , Biopsia con Aguja Fina , Carcinoma/diagnóstico por imagen , Carcinoma/cirugía , Carcinoma Papilar , Relación Dosis-Respuesta en la Radiación , Humanos , Radioisótopos de Yodo/uso terapéutico , Leucemia Linfocítica Crónica de Células B/complicaciones , Ganglios Linfáticos/patología , Recuento de Linfocitos , Masculino , Cáncer Papilar Tiroideo , Neoplasias de la Tiroides/diagnóstico por imagen , Neoplasias de la Tiroides/cirugía , Tiroidectomía/métodos , Factores de Tiempo , Tomografía Computarizada de Emisión de Fotón Único , Resultado del TratamientoRESUMEN
The authors report the case of a 70-year-old male patient with chronic lymphoid leukemia who presented subsequently a papillary carcinoma of the thyroid with metastases to regional lymph nodes. The patient was treated with surgical thyroidectomy with regional and cervical lymph node excision and radioiodine therapy (I-131). The protocolar control scintigraphy 4 days after the radioactive dose showed I-131 uptake in both axillae and even in the inguinal regions. PET/CT showed faint FDG-F-18 uptake in one lymph node of the left axilla. An ultrasound guided fine needle biopsy of this lymph node identified by I-131 SPECT/CT and FDG-F-18 PET/CT revealed lymphoma cells and was negative for thyroid tissue and thyroglobulin content. The sequential blood counts done routinely after radiation treatment showed a marked fall until return to normal values of leucocytes and lymphocytes (absolute and relative), which were still normal in the last control 19 months after the radioiodine administration. Chest computed tomography showed a decrease in size of axillary and para-aortic lymph nodes. By immunohistochemistry, cells of the lymphoid B lineage decreased from 52% before radioiodine therapy to 5% after the procedure. The authors speculate about a possible sodium iodide symporter expression by the cells of this lymphoma, similar to some other non-thyroid tumors, such as breast cancer cells.
Os autores relatam o caso de um paciente de 70 anos com leucemia linfóide crônica que apresentou subsequentemente um carcinoma papilífero da tireóide com metástases para linfonodos regionais. O paciente foi tratado com tireoidectomia total cirúrgica com exérese de linfonodos regionais e cervicais e radioiodoterapia (I-131). A pesquisa de corpo inteiro protocolar de controle 4 dias após a dose radioativa mostrou captação de I-131 em ambas as axilas e mesmo nas regiões inguinais. PET/CT mostrou discreta captação de FDG-F-18 em um linfonodo da axila esquerda. A biópsia por agulha fina guiada por ultrassom deste linfonodo identificado por SPECT/CT com I-131 e PET/CT com FDG-F-18 revelou células linfomatosas e foi negativa para tecido tireoidiano e conteúdo de tireoglobulina. Os hemogramas sequenciais feitos rotineiramente após tratamento com radiações mostraram uma acentuada queda até retorno aos valores normais de leucócitos e de linfócitos (absolutos e relativos), que continuavam normais no último controle 19 meses após a administração do radioiodo. Tomografia computadorizada de tórax mostrou uma redução em tamanho de linfonodos axilares e para-aorticos. Por imunohistoquímica, as células da linhagem linfoide B decresceram de 52% antes da radioiodoterapia para 5% depois do procedimento. Os autores conjeturam sobre uma possível expressão de symporter de iodeto de sódio pelas células deste linfoma, à semelhança de outros tumores não tireoidianos, tais como células de câncer da mama.
Asunto(s)
Anciano , Humanos , Masculino , Carcinoma/radioterapia , Carcinoma/secundario , Terapia por Láser/métodos , Leucemia Linfocítica Crónica de Células B/radioterapia , Neoplasias de la Tiroides/radioterapia , Neoplasias de la Tiroides/secundario , Biopsia con Aguja Fina , Carcinoma , Carcinoma/cirugía , Relación Dosis-Respuesta en la Radiación , Radioisótopos de Yodo/uso terapéutico , Recuento de Linfocitos , Leucemia Linfocítica Crónica de Células B/complicaciones , Ganglios Linfáticos/patología , Factores de Tiempo , Tomografía Computarizada de Emisión de Fotón Único , Resultado del Tratamiento , Neoplasias de la Tiroides , Neoplasias de la Tiroides/cirugía , Tiroidectomía/métodosRESUMEN
Apresentamos uma lista de recomendações sobre a utilização de 18F-FDG PET em oncologia, no diagnóstico, estadiamento e detecção de recorrência ou progressão do câncer. Foi realizada pesquisa para identificar estudos controlados e revisões sistemáticas de literatura composta por estudos retrospectivos e prospectivos. As consequências e o impacto da 18F-FDG PET no manejo de pacientes oncológicos também foram avaliados. A 18F-FDG PET deve ser utilizada como ferramenta adicional aos métodos de imagem convencionais como tomografia computadorizada e ressonância magnética. Resultados positivos que sugiram alteração no manejo clínico devem ser confirmados por exame histopatológico. A 18F-FDG PET deve ser utilizada no manejo clínico apropriado para o diagnóstico de cânceres do sistema respiratório, cabeça e pescoço, sistema digestivo, mama, melanoma, órgão genitais, tireoide, sistema nervoso central, linfoma e tumor primário oculto.
The authors present a list of recommendations on the utilization of 18F-FDG PET/CT in oncology for the diagnosis, staging and detection of cancer, as well as in the follow-up of the disease progression and possible recurrence. The recommendations were based on the analysis of controlled studies and a systematic review of the literature including both retrospective and prospective studies regarding the clinical usefulness and the impact of 18F-FDG PET/CT on the management of cancer patients. 18F-FDG PET/CT should be utilized as a supplement to other conventional imaging methods such as computed tomography and magnetic resonance imaging. Positive results suggesting changes in the clinical management should be confirmed by histopathological studies. 18F-FDG PET should be utilized in the diagnosis and appropriate clinical management of cancer involving the respiratory system, head and neck, digestive system, breast, genital organs, thyroid, central nervous system, besides melanomas, lymphomas and occult primary tumors.
Asunto(s)
Humanos , Masculino , Femenino , Oncología Médica , Imagen Multimodal , Neoplasias , Neoplasias/diagnóstico , Carcinoma/diagnóstico , Sistemas de Apoyo a Decisiones Clínicas , Melanoma/diagnóstico , Literatura de Revisión como AsuntoRESUMEN
OBJETIVO: O presente experimento visa a validar um protocolo de aquisição em 3D na tomografia por emissão de pósitrons, em substituição ao modo 2D, de forma a reduzir a dose de radiação nos pacientes, sem perda da qualidade de imagens. MATERIAIS E MÉTODOS: Foram realizadas 27 simulações em equipamento Discovery ST, nos modos 2D com quatro minutos de aquisição e 3D com dois e quatro minutos. Utilizou-se um simulador do protocolo da National Electrical Manufacturers Association. No interior deste simulador estão inseridas seis esferas com diferentes diâmetros para a determinação da qualidade de imagem. As aquisições foram comparadas por três médicos nucleares, sem que eles identificassem o modo de aquisição. Cada observador atribuiu o valor igual a 1 quando alguma esfera não foi identificada ou valor 2 para esferas visíveis. RESULTADOS: A análise qualitativa pelo kappa generalizado demonstrou que a frequência de esferasvisíveis foi maior no modo 3D com quatro minutos (85%) e a porcentagem de concordância também foi maior (88,9%), com kappa generalizado = 0,725 [0,507;0,942]. CONCLUSÃO: O modo 3D com quatro minutos de aquisição e com menores atividades de FDG-18F pode ser utilizado em pacientes com biótipo equivalente ao simulador, sem perda de qualidade de imagem.
OBJECTIVE: The present study is aimed at validating a 3D acquisition protocol for positron emission tomography as a replacement for the 2D mode, to reduce the radiation dose delivered to patients, without any loss in the quality of images. MATERIALS AND METHODS: The study comprised 27 simulations in a Discovery ST equipment with four-minute 2D acquisitions, and two-minute and four-minute 3D acquisitions, utilizinga chest phantom according to the National Electrical Manufacturers Association protocol. Six spheres withdifferent diameters were inserted into this phantom as a means for determining the images quality. The images were blindly reviewed by three experienced nuclear physicians who did not know the acquisition modes. Each observer attributed a score 1 when one of the spheres was not identified, or 2 for visible spheres. RESULTS: The qualitative analysis based on generalized kappa coefficient demonstrated that the frequency of visible spheres was higher with four-minute 3D acquisitions (85%), with an also higher interobserver agreement (88.9%), generalized kappa = 0.725 [0.507;0.942]. CONCLUSION: The protocol with four-minute 3D acquisition with lower 18F-FDG activity can be utilized for patients with a biotype similar to the phantom, without any loss in the imaging quality.