Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Crit Rev Food Sci Nutr ; : 1-19, 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38922612

RESUMEN

The nutritional benefits of combining probiotics with plant proteins have sparked increasing research interest and drawn significant attention. The interactions between plant proteins and probiotics demonstrate substantial potential for enhancing the functionality of plant proteins. Fermented plant protein foods offer a unique blend of bioactive components and beneficial microorganisms that can enhance gut health and combat chronic diseases. Utilizing various probiotic strains and plant protein sources opens doors to develop innovative probiotic products with enhanced functionalities. Nonetheless, the mechanisms and synergistic effects of these interactions remain not fully understood. This review aims to delve into the roles of promoting health through the intricate interplay of plant proteins and probiotics. The regulatory mechanisms have been elucidated to showcase the synergistic effects, accompanied by a discussion on the challenges and future research prospects. It is essential to recognize that the interactions between plant proteins and probiotics encompass multiple mechanisms, highlighting the need for further research to address challenges in achieving a comprehensive understanding of these mechanisms and their associated health benefits.

2.
Foods ; 10(12)2021 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-34945636

RESUMEN

Excessive lipid intake will cause hyperlipidemia, fatty liver metabolism disease, and endanger people's health. Edible fungus polysaccharide is a natural active substance for lipid lowering. In this study, the HepG2 cell model induced by oleic acid and mice model induced by a high-fat diet was established. The lipid-lowering effects of Inonotus obliquus polysaccharide (IOP) was investigated in vivo and in vitro. Glucose (251.33 mg/g), rhamnose (11.53 mg/g), ribose (5.10 mg/g), glucuronic acid (6.30 mg/g), and galacturonic acid (2.95 mg/g) are present in IOP, at a ratio of 85.2:3.91:1.73:2.14:1. The molecular weight of IOP is 42.28 kDa. Treatment with 60 mg/L of IOP showed a significant lipid-lowering effect in HepG2 cells compared with the oleic acid-treated group. In the oil red O-stained images, the red fat droplets in the IOP-treated groups were significantly reduced. TC and TG levels of IOP-treated groups decreased. IOP can alleviate the lipid deposition in the mice liver due to high-fat diet, and significantly reduce their serum TC, TG, and LDL-C contents. IOP could activate AMPK but decrease the SREBP-1C, FAS, and ACC protein expression related to adipose synthesis in mice. IOP has a certain potential for lipid-lowering effects both in vivo and in vitro.

3.
Rev Sci Instrum ; 89(10): 10D134, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399879

RESUMEN

A high-speed vacuum ultraviolet monochromator is developed for the HL-2A tokamak through the introduction of a novel channel electron multiplier in a modified Seya-Namioka spectrometer. A good signal to noise ratio of above 2000 is attained in the development phase of the system with typical operating parameters for observing routine HL-2A plasmas. The wavelength calibration is performed using characteristic line emissions from a hollow cathode light source with helium and argon discharges. The first measurement result of the monochromator at a sample rate of 60 kHz is presented in comparison with the visible Dα signals.

4.
Rev Sci Instrum ; 85(11): 11E426, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25430333

RESUMEN

A space-resolved grazing-incidence flat-field extreme ultraviolet (EUV) spectrometer has been developed in the HL-2A tokamak to measure vertical impurity emission profiles with simultaneous spectral, temporal, and spatial resolution. The spectrometer working in the wavelength range of 30-500 Å has been equipped with a gold-coated varied-line-spacing holographic grating with curvature of 5606 mm and a back illuminated charge-coupled device with size of 6.6 × 26.6 mm(2) (255 × 1024 pixels). A lower half of the HL-2A plasma with averaged minor radius of 40 cm is observed when the spectrometer with horizontal dispersion is placed at a distance of 7.5 m away from the plasma center. An excellent spatial resolution of 12 mm is achieved when a space-resolved slit with vertical width of 0.5 mm is adopted. The radial profiles of intrinsic impurities in several ionization stages have been measured with high throughput and extremely low stray light.

5.
Rev Sci Instrum ; 83(10): 10D507, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23126850

RESUMEN

A grazing-incidence flat-field extreme ultraviolet (EUV) spectrometer has been newly developed in HL-2A tokamak. Typical spectral lines are observed from intrinsic impurities of carbon, oxygen, iron, and extrinsic impurity of helium in the wavelength range of 20 Å-500 Å. Bremsstrahlung continuum is measured at different electron densities of HL-2A discharges to calibrate absolute sensitivity of the EUV spectrometer system and to measure effective ionic charge, Z(eff). The sensitivity of a vacuum ultraviolet (VUV) spectrometer system is also absolutely calibrated in overlapped wavelength range of 300 Å-500 Å by comparing the intensity between VUV and EUV line emissions.

6.
Rev Sci Instrum ; 81(4): 043503, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20441337

RESUMEN

A 1 m normal incidence vacuum ultraviolet (VUV) spectrometer has been developed for spatial distribution measurement of edge impurity line emission in the wavelength range of 300-3200 A on HL-2A tokamak. A vertical profile of the impurity line emission is measured with a space-resolved slit placed between an entrance slit and a grating of the spectrometer. Two concave 1200 grooves/mm gratings blazed at 800 and 1500 A are set on a rotatable holder in the spectrometer, which gives wavelength dispersion of 0.12 mm/A. A back-illuminated charge-coupled device is used as a detector with an image size of 6.7 x 26.6 mm(2) (26 x 26 microm(2)/pixel). An excellent spatial resolution of 2 mm is obtained with good spectral resolution of 0.15 A when the space-resolved slit of 50 microm in width is used. The space-resolved spectra thus provide three radial profiles of emission line intensity, ion temperature, and poloidal rotation. The electron temperature can be measured by the intensity ratio, e.g., CIII 2s(2)-2s3p (386 A)/2s(2)-2s2p (977 A). The sensitivity of the spectrometer is calibrated in situ by using the VUV bremsstrahlung continuum radiation emitted from the tokamak plasma. A good performance of the spectrometer system for the edge impurity and temperature profile measurements is presented with results on Ohmic and H-mode discharges.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA