RESUMEN
Internal dosimetry intercomparisons are essential for the verification of applied models and the consistency of results'. To that aim, the First Regional Intercomparison was organised in 2005, and that results led to the Second Regional Intercomparison Exercise in 2013, which was organised in the frame of the RLA 9/066 and coordinated by Autoridad Regulatoria Nuclear of Argentina. Four simulated cases covering intakes of (131)I, (137)Cs and Tritium were proposed. Ninteen centres from thirteen different countries participated in this exercise. This paper analyses the participants' results in this second exercise in order to test their skills and acquired knowledge, particularly in the application of the IDEAS Guidelines. It is important to highlight the increased number of countries that participated in this exercise compared with the first one and, furthermore, the improvement in the overall performance. The impact of the International Atomic Energy Agency (IAEA) Projects since 2003 has led to a significant enhancement of internal dosimetry capabilities that strengthen the radiation protection of workers.
Asunto(s)
Dosis de Radiación , Monitoreo de Radiación/métodos , Protección Radiológica/métodos , Contaminantes Radiactivos del Aire , Carga Corporal (Radioterapia) , Radioisótopos de Cesio/análisis , Guías como Asunto , Humanos , Agencias Internacionales , Cooperación Internacional , Radioisótopos de Yodo/análisis , América Latina , Exposición Profesional/análisis , Exposición Profesional/prevención & control , Monitoreo de Radiación/normas , Protección Radiológica/normas , Radioisótopos , Reproducibilidad de los Resultados , Medición de Riesgo/normas , Sensibilidad y Especificidad , Programas Informáticos , TritioRESUMEN
An in vivo intercomparison exercise, organised in the scope of the IAEA Regional Latin American (RLA) Project 9066, was carried out in 2009 aimed to harmonise measurement procedures on the measurement of (131)I in the thyroid among Latin American and Caribbean countries. The exercise consisted in the measurement of an anthropomorphic thyroid phantom spiked with a certified source of (133)Ba. The phantom was supplied by the In Vivo Monitoring Laboratory of Institute for Radiation Protection and Dosimetry (IRD) to 17 Institutions from 12 countries of the regions. Among these, 13 Institutions from 10 countries returned their measurement results as well as a standard report form containing detailed information about their respective counting facilities. All participants reported activities within an acceptable range, considering American National Standard Institute (ANSI) limits. Uncertainties varied from 0.04 to 12.9 %. Although results show that the general performance was acceptable in terms of accuracy, the need for additional action towards the standardisation of uncertainty estimation in this type of measurement in the region should be highlighted.
Asunto(s)
Radioisótopos de Yodo/análisis , Monitoreo de Radiación/métodos , Protección Radiológica/métodos , Radiometría/métodos , Bario/química , Región del Caribe , Humanos , América Latina , Fantasmas de Imagen , Cintigrafía , Reproducibilidad de los Resultados , Glándula Tiroides/diagnóstico por imagenRESUMEN
The concern about accidents involving radioactive materials has led to the search of alternative methods to quickly identify and quantify radionuclides in workers and in the population. One of the options to face up an eventual demand for mass monitoring of internal contamination is the use of a nuclear medicine diagnostic equipment known as gamma camera, a device used to scan patients who have been administered specific amounts of radioactive materials for medical purposes. Although the gamma camera is used for image diagnosis, it can be calibrated with anthropomorphic phantoms or point sources for the quantification of radionuclide activities in the human body. This work presents a protocol for the calibration of gamma cameras for such application. In order to evaluate the suitability of this type of equipment, a gamma camera available in a public hospital located in Rio de Janeiro was calibrated for the in vivo measurement of 131I. The calibration includes the determination of detection efficiencies and minimum detectable activities for each radionuclide. The results show that the gamma camera presents enough sensitivity to detect activity levels corresponding to effective doses below 1 mSv. The protocol is the basis to establish a network of Nuclear Medicine Centres, located in public hospitals in eight countries of Latin America (Argentina, Brazil, Colombia, Cuba, Chile, Mexico, Peru and Uruguay) and in Spain that could be requested to collaborate in remediation actions in the event of an accident involving incorporation of radioactive materials. This protocol is one of the most significant outputs of the IAEA-ARCAL Project (RLA/9/049-LXXVIII) aimed to the Harmonization of Internal Dosimetry Procedures.