Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Int J Radiat Oncol Biol Phys ; 88(1): 216-23, 2014 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-24331667

RESUMEN

PURPOSE: The aim of the present study was the investigation of different fractionation schemes to estimate their clinical impact. For this purpose, widely applied radiobiological models and dosimetric measures were used to associate their results with clinical findings. METHODS AND MATERIALS: The dose distributions of 12 clinical high-dose-rate brachytherapy implants for prostate were evaluated in relation to different fractionation schemes. The fractionation schemes compared were: (1) 1 fraction of 20 Gy; (2) 2 fractions of 14 Gy; (3) 3 fractions of 11 Gy; and (4) 4 fractions of 9.5 Gy. The clinical effectiveness of the different fractionation schemes was estimated through the complication-free tumor control probability (P+), the biologically effective uniform dose, and the generalized equivalent uniform dose index. RESULTS: For the different fractionation schemes, the tumor control probabilities were 98.5% in 1×20 Gy, 98.6% in 2×14 Gy, 97.5% in 3×11 Gy, and 97.8% in 4×9.5 Gy. The corresponding P+ values were 88.8% in 1×20 Gy, 83.9% in 2×14 Gy, 86.0% in 3×11 Gy, and 82.3% in 4×9.5 Gy. With use of the fractionation scheme 4×9.5 Gy as reference, the isoeffective schemes regarding tumor control for 1, 2, and 3 fractions were 1×19.68 Gy, 2×13.75 Gy, and 3×11.05 Gy. The optimum fractionation schemes for 1, 2, 3, and 4 fractions were 1×19.16 Gy with a P+ of 91.8%, 2×13.2 Gy with a P+ of 89.6%, 3×10.6 Gy with a P+ of 88.4%, and 4×9.02 Gy with a P+ of 86.9%. CONCLUSIONS: Among the fractionation schemes 1×20 Gy, 2×14 Gy, 3×11 Gy, and 4×9.5 Gy, the first scheme was more effective in terms of P+. After performance of a radiobiological optimization, it was shown that a single fraction of 19.2 to 19.7 Gy (average 19.5 Gy) should produce at least the same benefit as that given by the 4×9.5 Gy scheme, and it should reduce the expected total complication probability by approximately 40% to 55%.


Asunto(s)
Braquiterapia/métodos , Modelos Biológicos , Neoplasias de la Próstata/radioterapia , Traumatismos por Radiación/prevención & control , Braquiterapia/efectos adversos , Fraccionamiento de la Dosis de Radiación , Humanos , Masculino , Órganos en Riesgo/diagnóstico por imagen , Órganos en Riesgo/efectos de la radiación , Probabilidad , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Recto/diagnóstico por imagen , Recto/efectos de la radiación , Valores de Referencia , Efectividad Biológica Relativa , Carga Tumoral , Ultrasonografía Intervencional/métodos , Uretra/diagnóstico por imagen , Uretra/efectos de la radiación , Vejiga Urinaria/diagnóstico por imagen , Vejiga Urinaria/efectos de la radiación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA