1.
HPB (Oxford) ; 25(1): 63-72, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36253269

RESUMEN

BACKGROUND: Routine chemical venous thromboembolism (VTE) prophylaxis for liver surgery remains controversial, and often delayed post-operatively due to perceived bleeding risk. This study asked whether patients undergoing hepatectomy for colorectal metastases (CRM) were at risk from VTE pre-operatively, and the impact of hepatectomy on that risk. METHODS: Single-centre prospective observational cohort study of patients undergoing open hepatectomy for CRM, comparing pre-, peri- and post-operative haemostatic variables. RESULTS: Of 336 hepatectomies performed October 2017-December 2019, 60 resections in 57 patients were recruited. There were 28 (46.7%) major resections, with median (interquartile range [IQR]) blood loss 150.0 (76.3-263.7) mls, no blood transfusions, post-operative VTE events or deaths. Patients were prothrombotic pre-operatively (high median factor VIIIC and increased thrombin generation velocity index), an effect exacerbated post-hepatectomy. Major hepatectomies had a significantly greater median drop in Protein C, rise in Factor VIIIC and von Willebrand Factor, versus minor resections (p = 0.001, 0.005, 0.001 respectively). Patients with parenchymal transection times greater than median (40 min), had significantly increased median (IQR) PMBC-TFmRNA expression [1.65(0.93-2.70)2ddCt], versus quicker transections [0.99(0.69-1.28)2ddCt, p = 0.020]. CONCLUSIONS: Patients with CRM are prothrombotic pre-operatively, an effect exacerbated by hepatectomy, particularly longer, complex resections, suggesting chemical thromboprophylaxis be considered early in the patient pathway.


Asunto(s)
Neoplasias Colorrectales , Hepatectomía , Neoplasias Hepáticas , Trombofilia , Humanos , Anticoagulantes/uso terapéutico , Neoplasias Colorrectales/patología , Factor VIII , Hepatectomía/efectos adversos , Hígado/patología , Neoplasias Hepáticas/secundario , Neoplasias Hepáticas/cirugía , Estudios Prospectivos , Estudios Retrospectivos , Trombofilia/etiología , Tromboembolia Venosa/diagnóstico , Tromboembolia Venosa/etiología , Tromboembolia Venosa/prevención & control
3.
HPB (Oxford) ; 16(7): 601-9, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24151899

RESUMEN

OBJECTIVES: There is debate concerning the best mode of delivery of analgesia following liver resection, with continuous i.m. infusion of bupivacaine (CIB) plus patient-controlled i.v. analgesia (PCA) suggested as an alternative to continuous epidural analgesia (CEA). This study compares these two modalities. METHODS: A total of 498 patients undergoing major hepatectomy between July 2004 and July 2011 were included. Group 1 received CIB + PCA (n = 429) and Group 2 received CEA (n = 69). Groups were analysed on baseline patient and surgical characteristics. Primary endpoints were pain severity scores and total opioid consumption. Secondary endpoints were pain management failures, need for rescue medication, postoperative (opioid-related) morbidity and hospital length of stay (LoS). RESULTS: In both groups pain was well controlled and >70% of patients had no or minimal pain on PoDs 1 and 2. The numbers of patients experiencing severe pain were similar in both groups: PoD 1 at rest: 0.3% in Group 1 and 0% in Group 2 (P = 1.000); PoD 1 on movement: 8% in Group 1 and 2% in Group 2 (P = 0.338); PoD 2 at rest: 0% in Group 1 and 2% in Group 2 (P = 0.126), and PoD 2 on movement: 5% in Group 1 and 5% in Group 2 (P = 1.000). Although the CIB + PCA group required more opioid rescue medication on PoD 0 (53% versus 22%; P < 0.001), they used less opioids on PoDs 0-3 (P ≤ 0.001), had lower morbidity (26% versus 39%; P = 0.018), and a shorter LoS (7 days versus 8 days; P = 0.005). CONCLUSIONS: The combination of CIB + PCA provides pain control similar to that provided by CEA, but facilitates lower opioid consumption after major hepatectomy. It has the potential to replace epidural analgesia, thereby avoiding the occurrence of rare but serious complications.


Asunto(s)
Analgesia Epidural , Analgesia Controlada por el Paciente , Analgésicos Opioides/administración & dosificación , Anestésicos Locales/administración & dosificación , Bupivacaína/administración & dosificación , Hepatectomía/efectos adversos , Manejo del Dolor/métodos , Dolor Postoperatorio/prevención & control , Adulto , Anciano , Anciano de 80 o más Años , Analgesia Epidural/efectos adversos , Analgesia Controlada por el Paciente/efectos adversos , Analgésicos Opioides/efectos adversos , Anestésicos Locales/efectos adversos , Bupivacaína/efectos adversos , Femenino , Humanos , Infusiones Parenterales , Tiempo de Internación , Masculino , Persona de Mediana Edad , Manejo del Dolor/efectos adversos , Dimensión del Dolor , Dolor Postoperatorio/diagnóstico , Dolor Postoperatorio/etiología , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
4.
Ann Intensive Care ; 2 Suppl 1: S12, 2012 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-22873413

RESUMEN

BACKGROUND: Current assumptions rely on intra-abdominal pressure (IAP) being uniform across the abdominal cavity. The abdominal contents are, however, a heterogeneous mix of solid, liquid and gas, and pressure transmission may not be uniform. The current study examines the upper and lower IAP following liver transplantation. METHODS: IAP was measured directly via intra-peritoneal catheters placed at the liver and outside the bladder. Compartmental pressure data were recorded at 10-min intervals for up to 72 h following surgery, and the effect of intermittent posture change on compartmental pressures was also studied. Pelvic intra-peritoneal pressure was compared to intra-bladder pressure measured via a FoleyManometer. RESULTS: A significant variation in upper and lower IAP of 18% was observed with a range of differences of 0 to 16 mmHg. A sustained difference in inter-compartmental pressure of 4 mmHg or more was present for 23% of the study time. Head-up positioning at 30° provided a protective effect on upper intra-abdominal pressure, resulting in a significant reduction in all patients. There was excellent agreement between intra-bladder and pelvic pressure. CONCLUSIONS: A clinically significant variation in inter-compartmental pressure exists following liver transplantation, which can be manipulated by changes to body position. The existence of regional pressure differences suggests that IAP monitoring at the bladder alone may under-diagnose intra-abdominal hypertension and abdominal compartment syndrome in these patients. The upper and lower abdomen may need to be considered as separate entities in certain conditions.

5.
World J Surg Oncol ; 7: 79, 2009 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-19860895

RESUMEN

BACKGROUND: Its a dilemma to attempt a palliative procedure to debulk the tumour and/or prevent future obstructive complications in a locally advanced intra abdominal malignancy. CASE PRESENTATION: A 38 year old Vietnamese man presented with a carcinoma of the colon which had invaded the gallbladder and duodenum with a sealed perforation of the second part of the duodenum. Following surgical exploration, it was evident that primary closure of the perforated duodenum was not possible due to the presence of unresectable residual tumour. CONCLUSION: We describe a novel technique using a covered duodenal stent deployed at open surgery to aid closure of a malignant duodenal perforation.


Asunto(s)
Adenocarcinoma/cirugía , Neoplasias del Colon/cirugía , Obstrucción Duodenal/cirugía , Cuidados Paliativos/métodos , Stents , Adenocarcinoma/complicaciones , Adenocarcinoma/diagnóstico por imagen , Adulto , Anastomosis Quirúrgica/métodos , Colecistectomía , Neoplasias del Colon/complicaciones , Neoplasias del Colon/patología , Colonoscopía , Neoplasias Duodenales/secundario , Obstrucción Duodenal/diagnóstico por imagen , Obstrucción Duodenal/etiología , Resultado Fatal , Neoplasias de la Vesícula Biliar/secundario , Humanos , Tiempo de Internación , Masculino , Complicaciones Posoperatorias/terapia , Radiografía
6.
Crit Care Med ; 37(7): 2187-90, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19487946

RESUMEN

OBJECTIVE: Elevated intra-abdominal pressure (IAP) is a frequent cause of morbidity and mortality among the critically ill. IAP is most commonly measured using the intravesicular or "bladder" technique. The impact of changes in body position on the accuracy of IAP measurements, such as head of bed elevation to reduce the risk of ventilator-associated pneumonia, remains unclear. DESIGN: Prospective, cohort study. SETTING: Twelve international intensive care units. PATIENTS: One hundred thirty-two critically ill medical and surgical patients at risk for intra-abdominal hypertension and abdominal compartment syndrome. INTERVENTIONS: Triplicate intravesicular pressure measurements were performed at least 4 hours apart with the patient in the supine, 15 degrees , and 30 degrees head of bed elevated positions. The zero reference point was the mid-axillary line at the iliac crest. MEASUREMENTS AND MAIN RESULTS: Mean IAP values at each head of bed position were significantly different (p < 0.0001). The bias between IAPsupine and IAP15 degrees was 1.5 mm Hg (1.3-1.7). The bias between IAPsupine and IAP30 degrees was 3.7 mm Hg (3.4-4.0). CONCLUSIONS: Head of bed elevation results in clinically significant increases in measured IAP. Consistent body positioning from one IAP measurement to the next is necessary to allow consistent trending of IAP for accurate clinical decision making. Studies that involve IAP measurements should describe the patient's body position so that these values may be properly interpreted.


Asunto(s)
Abdomen , Síndromes Compartimentales/diagnóstico , Cuidados Críticos , Postura/fisiología , Presión , Cateterismo Urinario/métodos , Administración Intravesical , Adulto , Anciano , Estudios de Cohortes , Síndromes Compartimentales/epidemiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Factores de Riesgo , Transductores
7.
ANZ J Surg ; 79(3): 192-7, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19317788

RESUMEN

Surgical education and training is evolving as new educational techniques are developed amidst a greater societal requirement and pressure for a greater number of surgeons. The methods of delivering this education and training vary between institutions, but all have the common aim to produce effective well-rounded surgeons who are capable of providing a safe and competent service that is relevant to the society within which they work.


Asunto(s)
Cirugía General/educación , Internado y Residencia , Sociedades Médicas , Australasia , Competencia Clínica , Educación , Humanos , Enseñanza
8.
J Pediatr Surg ; 44(2): 441-3, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19231553

RESUMEN

Dieulafoy lesions are a rather uncommon cause of gastrointestinal bleeding that can be torrential and life-threatening. Extragastric location and pediatric cases are very rare. We report the first case of synchronous Dieulafoy lesions in the stomach and jejunum. This case is discussed in the light of the reported literature on this condition.


Asunto(s)
Hemorragia Gastrointestinal/etiología , Yeyuno/irrigación sanguínea , Estómago/irrigación sanguínea , Enfermedades Vasculares/complicaciones , Adolescente , Arterias , Femenino , Humanos
9.
HPB (Oxford) ; 11(7): 533-40, 2009 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20495704

RESUMEN

BACKGROUND: Despite a growing body of evidence reporting the deleterious mechanical and oncological complications of biopsy of hepatic malignancy, a small but significant number of patients undergo the procedure prior to specialist surgical referral. Biopsy has been shown to result in poorer longterm survival following resection and advances in modern imaging modalities provide equivalent, or better, diagnostic accuracy. METHODS: The literature relating to needle-tract seeding of primary and secondary liver cancers was reviewed. MEDLINE, EMBASE and the Cochrane Library were searched for case reports and series relating to the oncological complications of biopsy of liver malignancies. Current non-invasive diagnostic modalities are reviewed and their diagnostic accuracy presented. RESULTS: Biopsy of malignant liver lesions has been shown to result in poorer longterm survival following resection and does not confer any diagnostic advantage over a combination of non-invasive imaging techniques and serum tumour markers. CONCLUSIONS: Given that chemotherapeutic advances now often permit downstaging and subsequent resection of 'unresectable' disease, the time has come to abandon biopsy of solid lesions outside the setting of a specialist multi-disciplinary team meeting (MDT).

10.
Intensive Care Med ; 34(7): 1299-303, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18389215

RESUMEN

OBJECTIVE: To investigate the effect of different reference transducer positions on intra-abdominal pressure (IAP) measurement. Three reference levels were studied: the symphysis pubis; the phlebostatic axis; and the midaxillary line at the level of the iliac crest. DESIGN: Prospective cohort study. SETTING: The intensive care units of participating hospitals PATIENTS AND PARTICIPANTS: One hundred thirty-two critically ill patients at risk for intra-abdominal hypertension (IAH). INTERVENTIONS: In each patient, three sets of IAP measurements were obtained in the supine position, using the different reference levels. The IAP measurements obtained at the different reference levels were compared using a paired t-test and Bland-Altman statistics were calculated. MEASUREMENTS AND RESULTS: IAP(phlebostatic) (9.9 +/- 4.67 mmHg) and IAP(pubis) (8.4 +/- 4.60 mmHg) were significantly lower that IAP(midax) (12.2 +/- 4.66 mmHg; p < 0.0001 for both comparisons). The bias between the IAP(midax) and IAP(pubis) was 3.8 mmHg (95% CI 3.5-4.1) and 2.3 mmHg (95% CI 1.9-2.6) between the IAP(midax) and the IAP(phlebostatic). The precision was 3.03 and 3.40, respectively. CONCLUSIONS: In the supine position, IAP(midax) is higher than both IAP(phlebostatic) and IAP(pubis), differences found to be clinically significant; therefore, the symphysis pubis or phlebostatic axis reference lines are not interchangeable with the midaxillary level.


Asunto(s)
Abdomen , Síndromes Compartimentales/diagnóstico , Enfermedad Crítica , Presión , Síndromes Compartimentales/fisiopatología , Humanos , Unidades de Cuidados Intensivos
11.
Breast J ; 13(3): 238-42, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17461897

RESUMEN

Breast cancer surgery is an emotive topic and rather than just simple cosmetic issues, the final appearance of the operated breast has been shown to have a significant impact on psychologic well-being and overall quality of life. Wide local excision (WLE) is a popular conservative approach to small tumors, which do not involve the nipple-areolar complex. This study compares WLE via an anterior and lateral approach. A retrospective survey of patient satisfaction was performed using a recognized and validated Body Image Score (BIS), which was sent to a total of 267 patients who had undergone WLE by either the anterior or lateral approach. The response rate was 57%, of which 89 women had undergone surgery via the anterior and 80 by the lateral approach. There was no significant difference in BIS when comparing the anterior and lateral approaches, despite concerns regarding the physical appearance of the scar and postoperative breast expressed by patients. Generally, surgery on the upper part of the breast was associated with less satisfaction than the lower, but "hiding" the scar with a lateral approach did not improve satisfaction. Surgeons should be reassured that the approach to WLE of early breast cancers has no impact on the patients overall body image and that the choice of technique should be based on the patient's personal preference and the surgeons experience and skill.


Asunto(s)
Imagen Corporal , Neoplasias de la Mama/psicología , Neoplasias de la Mama/cirugía , Mastectomía Segmentaria/psicología , Satisfacción del Paciente , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de la Mama/patología , Femenino , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Calidad de Vida , Resultado del Tratamiento , Salud de la Mujer
12.
Arch Surg ; 137(10): 1166-9, 2002 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-12361428

RESUMEN

HYPOTHESIS: A shadow-inducing laparoscopic system improves task performance. DESIGN: Experimental study was carried out using the Dundee Endoscopic Psychomotor Tester for objective assessment of task performance. The standard exercise consisted of passing a probe through 37 holes on the target plate in a random order. Shadow was induced by using separate ports for illumination and imaging of the target plate. Light direction-to-target (LDT) angles of 90 degrees, 75 degrees, and 60 degrees were investigated with each of the 90 degrees and 75 degrees optical axis-to-target view angles. SETTING: Research laboratory at the Surgical Skills Unit, Ninewells Hospital. PARTICIPANTS: Twenty medical students with no previous exposure to laparoscopic surgery. MAIN OUTCOME MEASURES: Success score, execution time, the force applied on the target, and angular deviations of the probe. RESULTS: With a 90 degrees optical axis-to-target angle, there was improvement in the success score using either 75 degrees or 60 degrees LDT angles compared with a 90 degrees LDT angle (P =.02, P =.01, respectively), but the execution time became longer (P =.008, P =.03, respectively). With a 75 degrees optical axis-to-target angle, there was improvement in the success score (P<.001), execution time (P<.001, P =.03, respectively), and horizontal and vertical deviations (P<.001) on using either 90 degrees or 60 degrees LDT angles compared with a 75 degrees LDT angle. CONCLUSION: Endoscopic task performance significantly improves with a system that provides illumination and shadows in the operative field.


Asunto(s)
Endoscopios , Endoscopía/métodos , Iluminación , Análisis y Desempeño de Tareas , Señales (Psicología) , Tecnología de Fibra Óptica , Humanos
SELECCIÓN DE REFERENCIAS