Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Acad Radiol ; 21(8): 986-93, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25018070

RESUMEN

RATIONALE AND OBJECTIVES: Previous cross-sectional studies have demonstrated that airway wall thickness and air trapping are greater in subjects with severe asthma than in those with mild-to-moderate asthma. However, a better understanding of how airway remodeling and lung density change over time is needed. This study aimed to evaluate predictors of airway wall remodeling and change in lung function and lung density over time in severe asthma. MATERIALS AND METHODS: Phenotypic characterization and quantitative multidetector-row computed tomography (MDCT) of the chest were performed at baseline and ∼2.6 years later in 38 participants with asthma (severe n = 24 and mild-to-moderate n = 14) and nine normal controls from the Severe Asthma Research Program. RESULTS: Subjects with severe asthma had a significant decline in postbronchodilator forced expiratory volume in 1 second percent (FEV1%) predicted over time (P < .001). Airway wall thickness measured by MDCT was increased at multiple airway generations in severe asthma compared to mild-to-moderate asthma (wall area percent [WA%]: P < .05) and normals (P < .05) at baseline and year 2. Over time, there was an increase in WA% and wall thickness percent (WT%) in all subjects (P = .030 and .009, respectively) with no change in emphysema-like lung or air trapping. Baseline prebronchodilator FEV1% inversely correlated with WA% and WT% (both P < .05). In a multivariable regression model, baseline WA%, race, and health care utilization were predictors of subsequent airway remodeling. CONCLUSIONS: Severe asthma subjects have a greater decline in lung function over time than normal subjects or those with mild-to-moderate asthma. MDCT provides a noninvasive measure of airway wall thickness that may predict subsequent airway remodeling.


Asunto(s)
Remodelación de las Vías Aéreas (Respiratorias) , Asma/diagnóstico por imagen , Enfermedades Bronquiales/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Pulmón/fisiopatología , Tomografía Computarizada Multidetector/métodos , Adulto , Asma/complicaciones , Enfermedades Bronquiales/complicaciones , Femenino , Humanos , Estudios Longitudinales , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
2.
Chest ; 134(6): 1183-1191, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18641116

RESUMEN

BACKGROUND: To prospectively apply an automated, quantitative three-dimensional approach to imaging and airway analysis to assess airway remodeling in asthma patients. METHODS: Using quantitative software (Pulmonary Workstation, version 0.139; VIDA Diagnostics; Iowa City, IA) that enables quantitative airway segment measurements of low-dose, thin-section (0.625 to 1.25 mm), multidetector-row CT (MDCT) scans, we compared airway wall thickness (WT) and wall area (WA) in 123 subjects participating in a prospective multicenter cohort study, the National Institutes of Health Severe Asthma Research Program (patients with severe asthma, n = 63; patients with mild-to-moderate asthma, n = 35); and healthy subjects, n = 25). A subset of these subjects underwent fiberoptic bronchoscopy and endobronchial biopsies (n = 32). WT and WA measurements were corrected for total airway diameter and area: WT and WA, respectively. RESULTS: Subjects with severe asthma had a significantly greater WT% than patients with mild-to-moderate asthma and healthy subjects (17.2 +/- 1.5 vs 16.5 +/- 1.6 [p = 0.014] and 16.3 +/- 1.2 [p = 0.031], respectively) and a greater WA percentage (WA%) compared to patients with mild-to-moderate asthma and healthy subjects (56.6 +/- 2.9 vs 54.7 +/- 3.3 [p = 0.005] and 54.6 +/- 2.4 [p = 0.003], respectively). Both WT% and WA% were inversely correlated with baseline FEV(1) percent predicted (r = -0.39, p < 0.0001 and r = -0.40, p < 0.0001, respectively) and positively correlated with response to a bronchodilator (r = 0.28, p = 0.002 and r = 0.35, p < 0.0001, respectively). The airway epithelial thickness measure on the biopsy sample correlated with WT% (r = 0.47; p = 0.007) and WA% (r = 0.52; p = 0.003). In the same individual, there is considerable regional heterogeneity in airway WT. CONCLUSION: Patients with severe asthma have thicker airway walls as measured on MDCT scan than do patients with mild asthma or healthy subjects, which correlates with pathologic measures of remodeling and the degree of airflow obstruction. MDCT scanning may be a useful technique for assessing airway remodeling in asthma patients, but overlap among the groups limits the diagnostic value in individual subjects.


Asunto(s)
Asma/diagnóstico por imagen , Asma/patología , Procesamiento de Imagen Asistido por Computador , Mucosa Respiratoria/diagnóstico por imagen , Mucosa Respiratoria/patología , Tomografía Computarizada por Rayos X , Adolescente , Adulto , Antiasmáticos/uso terapéutico , Asma/terapia , Membrana Basal/diagnóstico por imagen , Membrana Basal/patología , Femenino , Volumen Espiratorio Forzado , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Adulto Joven
3.
Acad Radiol ; 15(6): 799-808, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18486015

RESUMEN

RATIONALE AND OBJECTIVES: Application of a previously developed model-based algorithm on hyperpolarized (HP) (3)He magnetic resonance (MR) dynamic projection images of phantoms was extended to investigate the utility of HP (3)He MR imaging (MRI) in quantifying airway caliber changes associated with asthma. MATERIALS AND METHODS: Airways of seven volunteers were imaged and measured using HP (3)He MRI and multidetector-row computed tomography (MDCT) before and after a methacholine (MCh) challenge. MDCT data were obtained at functional residual capacity and 1 L above functional residual capacity. RESULTS: Comparison of the resultant data showed that HP (3)He MRI did not match MDCT in measuring the ratios of airway calibers before and after the MCh challenge in 37% to 43% of the airways from the first six generations at the two lung volumes tested. However, MDCT did yield the observation that 49% to 69% of these airways displayed bronchodilation following MCh challenge. CONCLUSION: The current implementation of HP (3)He MRI did not match the MCh-induced postchallenge-to-prechallenge airway caliber ratios as measured with MDCT. Elevated parenchymal tethering due to bronchoconstriction-induced hyperinflation was proposed as a possible explanation for this airway dilation.


Asunto(s)
Asma/fisiopatología , Helio , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Administración por Inhalación , Adulto , Algoritmos , Bronquios/fisiopatología , Femenino , Capacidad Residual Funcional , Humanos , Aumento de la Imagen/métodos , Isótopos , Masculino , Persona de Mediana Edad , Intensificación de Imagen Radiográfica/métodos , Pruebas de Función Respiratoria , Tráquea/fisiopatología
4.
Magn Reson Med ; 58(3): 636-42, 2007 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17763351

RESUMEN

An anthropomorphic airway tree phantom was imaged with both hyperpolarized (HP) 3He MRI using a dynamic projection scan and computed tomography (CT). Airway diameter measurements from the HP 3He MR images obtained using a newly developed model-based algorithm were compared against their corresponding CT values quantified with a well-established method. Of the 45 airway segments that could be evaluated with CT, only 14 airway segments (31%) could be evaluated using HP 3He MRI. No airway segments smaller than approximately 4 mm in diameter and distal to the fourth generation were adequate for analysis in MRI. For the 14 airway segments measured, only two airway segments yielded a non-equivalent comparison between the two imaging modalities, while eight more had inconclusive comparison results, leaving only four airway segments (29%) that satisfied the designed equivalence criteria. Some of the potential problems in airway diameter quantification described in the formulation of the model-based algorithm were observed in this study. These results suggest that dynamic projection HP 3He MRI may have limited utility for measuring airway segment diameters, particularly those of the central airways.


Asunto(s)
Helio , Procesamiento de Imagen Asistido por Computador/métodos , Pulmón/anatomía & histología , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Bronquios/anatomía & histología , Gráficos por Computador , Humanos , Aumento de la Imagen/métodos , Isótopos , Alveolos Pulmonares/anatomía & histología , Intensificación de Imagen Radiográfica/métodos , Tráquea/anatomía & histología
5.
Respiration ; 74(4): 423-31, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17641484

RESUMEN

BACKGROUND: Mediastinal and perihilar lymph node samples can be acquired safely through the transbronchial approach during a bronchoscopic examination that is usually required as part of the evaluation of suspected lung cancer. Typically, needle aspiration samples are performed and needle cores can be sampled if the operator is confident that the needle is within the lymph node target, partly because of the risk of bleeding if a large blood vessel is sampled during core biopsy, especially in the perihilar region. Many bronchoscopists have difficulty assessing the three-dimensional (3D) positioning for needle sampling during these procedures, especially when relying on multidetector-row computerized tomography (MDCT) images displayed two-dimensionally seen prior to and usually during the procedure. OBJECTIVE: We have developed and evaluated a process model and associated software for providing interactive 3D displays of the MDCT data for procedure planning and real-time virtual bronchoscopic pathfinding for these procedures. METHODS: We undertook a prospective randomized clinical study for evaluating the computer-aided pathfinding assistance in mediastinal lymph node biopsies in 87 consenting subjects. RESULTS: We demonstrate that the addition of this computer-aided pathfinding improved operator performance in perihilar and paratracheal lymph node sampling (100 vs. 69%) but not in subcarinal sampling (82 vs. 85%). Overall success with lymph node sampling is 92% using the computer-aided method and 77% using standard clinical practice. CONCLUSIONS: The type of computer-aided pathway assistance described here, using 3D MDCT scanning information obtained before the procedure, but interacting with real-time bronchoscopic images during the bronchoscopic procedure, should improve the confidence of most bronchoscopists in performing these procedures, with improved clinical outcomes, and will add to the personalization of medicine through imaging.


Asunto(s)
Broncoscopía/métodos , Diagnóstico por Computador/instrumentación , Neoplasias Pulmonares/diagnóstico , Ganglios Linfáticos/patología , Tomografía Computarizada por Rayos X/métodos , Biopsia con Aguja/métodos , Femenino , Estudios de Seguimiento , Humanos , Neoplasias Pulmonares/secundario , Ganglios Linfáticos/diagnóstico por imagen , Metástasis Linfática/diagnóstico , Masculino , Mediastino , Estudios Prospectivos , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Interfaz Usuario-Computador
6.
Respiration ; 72(6): 579-86, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-16155354

RESUMEN

BACKGROUND: Balloon dilatation (BD) is a useful method of treating tracheobronchial stenosis (TBS); however, accurate preoperative identification of the lesion is difficult. Three-dimensional computed tomography (3D-CT) is an imaging method that may allow more accurate definition of the lesion(s) preoperatively. STUDY OBJECTIVE: It is the aim of this study to present our finding using 3D-CT as a part of the preoperative evaluation of patients with TBS undergoing BD. METHODS: We studied a prospective case series of 17 consecutive patients who underwent 29 BDs for TBS from a variety of benign and malignant causes at a tertiary care hospital. All patients had a preoperative spiral CT; these data were processed by a software program, VIDA, which was developed at this institution, and 3D-CT reconstruction images of the TBS were created. This enabled accurate preoperative anatomic definition of the lesion. The patients subsequently underwent BD. RESULTS: All 17 patients had lesions identified with 3D-CT. Six patients had tracheal lesions and 12 patients had main stem lesions. One patient had combined tracheal and main stem lesions and 2 other patients had bilateral main stem lesions. Nine out of 17 patients required only one BD. One patient had a failed BD. The remaining 6 patients required more than one BD for optimal results (up to a maximum of 4). The follow-up period ranged from 1 to 34 months. CONCLUSIONS: 3D-CT offers accurate definition of TBS, including anatomic location, number of lesions present and status of airway distal to lesion. In this study, all preoperative lesions were correctly identified prior to BD.


Asunto(s)
Enfermedades Bronquiales/terapia , Broncografía , Cateterismo , Cuidados Preoperatorios/métodos , Tomografía Computarizada Espiral/métodos , Tráquea/diagnóstico por imagen , Estenosis Traqueal/terapia , Adulto , Anciano , Enfermedades Bronquiales/diagnóstico por imagen , Constricción Patológica/diagnóstico por imagen , Constricción Patológica/terapia , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Estenosis Traqueal/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA