Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Gels ; 10(8)2024 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-39195067

RESUMEN

The OphthalMimic is a 3D-printed device that simulates human ocular conditions with artificial lacrimal flow, cul-de-sac area, moving eyelid, and a surface to interact with ophthalmic formulations. All tests with such a device have used a continuous artificial tear flow rate of 1 mL/min for 5 min. Here, we implemented protocol variations regarding the application time and simulated tear flow to increase the test's discrimination and achieve reliable performance results. The new protocols incorporated the previously evaluated 0.2% fluconazole formulations containing or not chitosan as a mucoadhesive component (PLX16CS10 and PLX16, respectively) and novel moxifloxacin 5% formulations, either in a conventional formulation and a microemulsion (CONTROL and NEMOX, respectively). The flow rate was reduced by 50%, and a pre-flow application period was also included to allow formulation interaction with the membrane. The OphthalMimic model was used with both polymeric and hydrogel-based hybrid membranes, including a simulated eyelid. Lowering the flow made it feasible to prolong the testing duration, enhancing device discrimination potential. The hydrogel membrane was adequate for testing nanostructure formulations. The OphthalMimic device demonstrated once again to be a versatile method for evaluating the performance of ophthalmic drug formulations with the potential of reducing the use of animals for experimentation.

2.
Methods ; 228: 1-11, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38759909

RESUMEN

The necessity of animal-free performance tests for novel ophthalmic formulation screening is challenging. For this, we developed and validated a new device to simulate the dynamics and physical-chemical barriers of the eye for in vitro performance tests of topic ophthalmic formulations. The OphthalMimic is a 3D-printed device with an artificial lacrimal flow, a cul-de-sac area, a support base, and a simulated cornea comprised of a polymeric membrane containing poly-vinyl alcohol 10 % (w/v), gelatin 2.5 % (w/v), and different proportions of mucin and poloxamer, i.e., 1:1 (M1), 1:2 (M2), and 2:1 (M3) w/v, respectively. The support base is designed to move between 0° and 50° to replicate the movement of an eyelid. We challenged the model by testing the residence performance of poloxamer®407 16 % and poloxamer®407 16 % + chitosan 1 % (PLX16CS10) gels containing fluconazole. The test was conducted with a simulated tear flow of 1.0 mL.min-1 for 5 min. The OphthalMimic successfully distinguished PLX16 and PLX16C10 formulations based on their fluconazole drainage (M1: 65 ± 14 % and 27 ± 10 %; M2: 58 ± 6 % and 38 ± 9 %; M3: 56 ± 5 % and 38 ± 18 %). In conclusion, the OphthalMimic is a promising tool for comparing the animal-free performance of ophthalmic formulations.


Asunto(s)
Soluciones Oftálmicas , Poloxámero , Poloxámero/química , Soluciones Oftálmicas/química , Administración Oftálmica , Fluconazol/administración & dosificación , Impresión Tridimensional , Córnea/efectos de los fármacos , Córnea/metabolismo , Animales , Quitosano/química , Alternativas a las Pruebas en Animales/métodos , Lágrimas/química , Humanos , Gelatina/química
3.
Pharmaceutics ; 15(9)2023 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-37765293

RESUMEN

Animal models are still used in the research and development of ophthalmic drug products, mainly due to the difficulty in simulating natural physiological conditions with in vitro models, as there is a lack of dynamic protection mechanisms. Therefore, developing alternative ophthalmic models that evaluate drug penetration in the cornea while applying dynamic protection barriers is a contemporary challenge. This study aimed to develop a dynamic ex vivo model using porcine eyes with a simulated lacrimal flow to evaluate the performance of pharmaceutical drug products. A glass donor cell to support a simulated tear flow was designed, optimized, and custom-made. The system was challenged with different formulations (with fluconazole) including excipients with different viscosities (poloxamer 407) and mucoadhesive properties (chitosan). The results were compared to those obtained from a conventional excised cornea model mounted in Franz-type diffusion cells. The dynamic model could differentiate formulations, while the static model did not, overestimating ex vivo drug penetrated amounts. Hence, the dynamic model with simulated tear flow showed to be a simple and promising new alternative method for the drug penetration of ophthalmic formulations that ultimately can reduce the number of animals used in research.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA