Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 88(10): 103501, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29092496

RESUMEN

Injection of small (outer diameter = 0.8 mm) plastic pellets carrying embedded smaller (10 µg) tungsten grains is used to check calibrations of core tungsten line radiation diagnostics in support of the 2016 tungsten ring campaign in the DIII-D tokamak. Observed total brightness (1 eV-10 keV) and soft x-ray (1 keV-10 keV) brightness are found to be reasonably well (

2.
Rev Sci Instrum ; 87(11): 11E602, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910457

RESUMEN

A new gamma ray imager (GRI) is developed to probe the electron distribution function with 2D spatial resolution during runaway electron (RE) experiments at the DIII-D tokamak. The diagnostic is sensitive to 0.5-100 MeV gamma rays, allowing characterization of the RE distribution function evolution during RE growth and dissipation. The GRI consists of a lead "pinhole camera" mounted on the DIII-D midplane with 123 honeycombed tangential chords 20 cm wide that span the vessel interior. Up to 30 bismuth germanate (BGO) scintillation detectors capture RE bremsstrahlung radiation for Pulse Height Analysis (PHA) capable of discriminating up to 20 000 pulses per second. Digital signal processing routines combining shaping filters are performed during PHA to reject noise and record gamma ray energy. The GRI setup and PHA algorithms will be described and initial data from experiments will be presented. A synthetic diagnostic is developed to generate the gamma ray spectrum of a GRI channel given the plasma information and a prescribed distribution function. Magnetic reconstructions of the plasma are used to calculate the angle between every GRI sightline and orient and discriminate gamma rays emitted by a field-aligned RE distribution function.

3.
Phys Rev Lett ; 110(24): 245001, 2013 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-25165932

RESUMEN

High repetition rate injection of deuterium pellets from the low-field side (LFS) of the DIII-D tokamak is shown to trigger high-frequency edge-localized modes (ELMs) at up to 12× the low natural ELM frequency in H-mode deuterium plasmas designed to match the ITER baseline configuration in shape, normalized beta, and input power just above the H-mode threshold. The pellet size, velocity, and injection location were chosen to limit penetration to the outer 10% of the plasma. The resulting perturbations to the plasma density and energy confinement time are thus minimal (<10%). The triggered ELMs occur at much lower normalized pedestal pressure than the natural ELMs, suggesting that the pellet injection excites a localized high-n instability. Triggered ELMs produce up to 12× lower energy and particle fluxes to the divertor, and result in a strong decrease in plasma core impurity density. These results show for the first time that shallow, LFS pellet injection can dramatically accelerate the ELM cycle and reduce ELM energy fluxes on plasma facing components, and is a viable technique for real-time control of ELMs in ITER.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA