Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
JACC Case Rep ; 4(24): 101683, 2022 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-36438888

RESUMEN

We describe the novel transcatheter approach, with off-label application of LAA closure device, coiling, and concurrent left anterior descending stenting in the setting of left ventricular (LV) pseudoaneurysm. This case underlines collaboration among interventional cardiology, cardiothoracic, and neurosurgery teams in a challenging, nonsurgical candidate with high risk of LV pseudoaneurysm rupture, and death. (Level of Difficulty: Advanced.).

2.
JACC Case Rep ; 1(5): 796-802, 2019 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-34316934

RESUMEN

A 71-year-old male with endocarditis mediated severe paravalvular leak and nonischemic cardiomyopathy underwent percutaneous repair attempts with a closure device followed by valve-in-valve transcatheter aortic replacement procedure. The case was complicated by cardiac arrest requiring hemodynamic support with Impella placement and secondary iatrogenic central aortic insufficiency requiring further intervention. (Level of Difficulty: Beginner.).

3.
J Arrhythm ; 34(4): 441-449, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30167016

RESUMEN

BACKGROUND: Permanent pacemaker implantation is the most common complication after Transcatheter aortic valve replacement (TAVR) and is associated with worse outcomes and mortality. However, its impact on quality-of-life (QoL) outcomes remains unknown. METHODS: We included 383 consecutive patients undergoing TAVR from January 2012 to 2016 who completed a baseline Kansas City Cardiomyopathy Questionnaire (KCCQ-12) health survey. The clinical, laboratory, angiographic, QoL, mortality, and occurrence of poor outcomes (KCCQ-12 score < 45 or KCCQ decrease of ≥10 points) were obtained. RESULTS: The mean age was 83 ± 8 years, 51% were men, and majority were Caucasians (n = 364, 95%). Permanent pacemaker (PPM) was implanted in 11.5% of patients post-TAVR. PPM patients were more likely to have prior conduction disease including RBBB (25% vs 12%, P = .02) and PQ interval >250 ms (11% vs 5%, P = .07). One-month median KCCQ-12 scores were significantly lower among PPM patients (84.7 vs 68.8, P = .04), but did not differ significantly at 1-year (86.5 vs 90.6, P = .5) post-TAVR. Occurrence of poor outcomes did not differ significantly among those with or without PPM at 1 month (11% vs 7%, P = .39) and 1 year (13% vs 9%, P = .45), respectively. However, patients with poor QoL outcomes at 1 month post-TAVR also had significantly worse mortality during follow-up in unadjusted (31.3% vs 4.5%, P < .001) and adjusted (HR = 5.30, 95% [CI: 1.85-15.22, P = .002])analyses, respectively. CONCLUSION: Permanent pacemaker implantation is associated with short-term reduction in QoL without long-term implications post-TAVR. Patients with poor QoL post-TAVR also have significantly higher mortality.

4.
Indian Heart J ; 70 Suppl 3: S313-S318, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30595282

RESUMEN

OBJECTIVE: Neutrophil-to-lymphocyte ratio (NLR) has prognostic value in acute coronary syndromes. We investigated its utility for predicting heart failure (HF) admissions and major adverse cardiac outcomes in patients undergoing transcatheter aortic valve replacement (TAVR). METHODS: Data on clinical, laboratory, procedural, HF admissions, and major adverse cardiac events (MACEs) (all-cause mortality, recurrence of myocardial infarction requiring intervention, stroke) for 298 consecutive patients who underwent TAVR between 2012 and 2016 in our tertiary center were collected. RESULTS: Analysis included 298 patients. The mean age was 83 ± 8 years, 51% were males, and 95% were Caucasians. The median Society of Thoracic Surgeons risk score was 9 (interquartile range: 6.3-11.8). Receiver-operating curve analysis identified a cutoff value of NLR of 4.0 for MACE after TAVR and sensitivity of 68% and specificity of 68% {area under the curve [AUC] = 0.65 [95% confidence interval (CI): 0.51-0.79], p = 0.03}. An NLR of 4.0 for HF hospitalizations after TAVR and sensitivity of 60% and specificity of 57% [AUC = 0.61 (95% CI: 0.53-0.69), p = 0.01]. NLR ≥4.0 before TAVR significantly predicted MACE after TAVR (68.4% vs. 31.6%, p = 0.02) and HF hospitalizations (58.3% vs. 41.7%, p = 0.03). NLR with TAVR risk score increased the predictive value for MACE after TAVR from AUC = 0.61 (95% CI: 0.50-0.72, p = 0.06) to AUC = 0.69 (95% CI: 0.57-0.80, p = 0.007). CONCLUSION: NLR predicts all-cause mortality, MACE, and HF hospitalization 1 year after TAVR. NLR with TAVR risk score improved predictability for MACE. Further studies for prognostication using NLR are warranted.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Insuficiencia Cardíaca/sangre , Linfocitos , Neutrófilos , Readmisión del Paciente/tendencias , Medición de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Femenino , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/etiología , Humanos , Incidencia , Masculino , Pronóstico , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento , Estados Unidos/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA