PURPOSE: To assess outcomes and glaucoma management in eyes with aniridia following Boston type 1 Keratoprosthesis (KPro) implantation. DESIGN: Retrospective, interventional comparative case series. METHODS: The population included patients with aniridia and patients with other preoperative diagnoses (excluding Stevens-Johnson syndrome, mucous membrane pemphigoid, and congenital disorders) who underwent KPro implantation at Massachusetts Eye and Ear with at least 2 years of follow-up. One eye per patient was selected based on the longer follow-up time. The main outcome was intermediate and long-term outcomes related to glaucoma. RESULTS: The aniridia (n = 22) and comparison (n = 61) groups had similar preoperative visual acuity (VA, mean ± standard deviation, 1.86 ± 0.52 logMAR, P = .33) and follow-up time (65.6 ± 26.3 months, P = .25). Before KPro implantation, eyes with aniridia had more glaucoma (76.2%) and glaucoma surgery (57.1%) than comparison eyes (51.8%, P = .053; 23.2%, P = .005, respectively). More Ahmed valves were co-implanted with KPro in aniridia (47.6%) vs comparison eyes (17.9%, P = .008). At final follow-up, more aniridia eyes had glaucoma (90.5%) than comparison eyes (64.3%, P = .02), but the 2 groups had similar percentages of eyes with cup-to-disc ratio (CDR) >0.8 (23.8% vs. 30.4%, P = .57) or CDR progression of ≥0.2 (42.9% vs 44.6%, P = .89, respectively). None of the eyes with prophylactic tube implantation developed glaucoma. Eyes with and without aniridia did not differ in post-KPro VA improvement (72.7%, 72.1%, P = .96), and final VA (1.28 ± 0.79 logMAR, 1.23 ± 0.98 logMAR, P = .51). CONCLUSION: Despite a higher glaucoma prevalence, eyes with aniridia achieved similar VA as comparison eyes with more than 5 years of mean follow-up time. Boston KPro offers satisfactory visual rehabilitation in aniridia when glaucoma is managed aggressively.
Asunto(s)
Aniridia/complicaciones , Órganos Artificiales , Enfermedades de la Córnea/cirugía , Implantes de Drenaje de Glaucoma , Glaucoma/cirugía , Complicaciones Posoperatorias , Prótesis e Implantes , Adulto , Anciano , Córnea , Femenino , Estudios de Seguimiento , Glaucoma/etiología , Glaucoma/fisiopatología , Humanos , Presión Intraocular/fisiología , Masculino , Persona de Mediana Edad , Implantación de Prótesis , Estudios Retrospectivos , Tonometría Ocular , Agudeza Visual/fisiologíaRESUMEN
PURPOSE: To quantitatively evaluate the angle anatomy in eyes with the Boston type I keratoprosthesis (B-KPro) differing in the back plate (BP) material and size using anterior segment optical coherence tomography. METHODS: B-KPro eyes with poly(methyl methacrylate) (PMMA) (7.0 and 8.5 mm) and titanium (7.0, 8.5, and 9.5 mm) BPs were imaged with anterior segment optical coherence tomography. The angle opening distance at 500 µm from the scleral spur (AOD500), trabecular iris surface area at 500 µm from the scleral spur (TISA500), and trabecular iris angle at 500 µm from the scleral spur (TIA500) were measured. Among the visible quadrants, the average, the temporal, the widest, and the narrowest angle of each eye were included in the analysis. Average time between B-KPro implantation and imaging was 7.5 ± 1.4 years for a PMMA BP and 2.4 ± 2.3 years for a titanium BP (P < 0.0001). RESULTS: We analyzed 17 B-KPro eyes with PMMA BPs and 24 B-KPro eyes with titanium BPs. The average AOD500 (394.1 ± 226.9 vs. 454.5 ± 255.6 µm, P = 0.44), average TIA500 (26.2 ± 14.2 vs. 29.8 ± 13.9 degrees, P = 0.43), and average TISA500 (0.15 ± 0.08 vs. 0.17 ± 0.10 µm, P = 0.52) were not statistically different between eyes with PMMA and titanium BPs, nor were the temporal, the narrowest, and the widest angle measurements of each eye (all P > 0.05). Similarly, no significant differences were found between the angle measurements of B-KPro eyes with a titanium BP diameter of 8.5 or 9.5 mm (all P > 0.05). CONCLUSIONS: We successfully visualized the angle anatomy in 66.1% of the imaged eyes, including all BPs studied. Neither the material nor the size of the B-KPro BP had a significant impact on the angle anatomy.