1.
Eur J Ophthalmol ; 29(4): 417-425, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30198329

RESUMEN

PURPOSE: To compare rotational stability, centration and visual outcomes provided by three trifocal lens models that have the same optical zone design but different material, composition, and/or toricity. METHODS: The study included 78 patients with symmetric bilateral intraocular lens implantation. The lenses under evaluation were trifocal intraocular lenses made of hydrophilic acrylic material: a spherical lens 26% hydrophilic acrylic (POD FineVision), a similar lens but having a toric design (POD Toric FineVision), and a trifocal lens 25% hydrophilic acrylic material (FineVision/MicroF). Moreover, the lenses share the same optical zone design. The lenses' rotational stability and centration were measured by means of the PIOLET software, which relies on recording and image processing techniques to determine lens rotation and centration based on slit-lamp images. We also assessed patients' visual quality by means of 25, 40, and 80 cm VA tests. RESULTS: The best centration results were achieved with the POD Toric FineVision model, although the differences were not statistically significant. As for lens rotation, it was below 5° in all cases under study. Regarding VA, all subjects attained at least 0.3 logMAR for far distance uncorrected VA, at 80 cm VA was about 0.2 logMAR, at 40 cm it was above 0.15 logMAR, and at 25 cm it was about 0.3 logMAR for both lens types. CONCLUSION: All three intraocular lens models yield excellent visual results at far, near as well as intermediate distances. The POD FineVision and POD Toric FineVision models, with double C-loop design, yielded the best results centration-wise and rotation-wise. Differences had no clinical relevance.


Asunto(s)
Implantación de Lentes Intraoculares , Lentes Intraoculares Multifocales , Facoemulsificación , Agudeza Visual/fisiología , Anciano , Catarata/complicaciones , Anteojos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Seudofaquia/fisiopatología , Rotación
2.
Sensors (Basel) ; 10(4): 3655-80, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-22319318

RESUMEN

This paper presents a sensor system for robot localization based on the information obtained from a single camera attached in a fixed place external to the robot. Our approach firstly obtains the 3D geometrical model of the robot based on the projection of its natural appearance in the camera while the robot performs an initialization trajectory. This paper proposes a structure-from-motion solution that uses the odometry sensors inside the robot as a metric reference. Secondly, an online localization method based on a sequential Bayesian inference is proposed, which uses the geometrical model of the robot as a link between image measurements and pose estimation. The online approach is resistant to hard occlusions and the experimental setup proposed in this paper shows its effectiveness in real situations. The proposed approach has many applications in both the industrial and service robot fields.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA