Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Dairy Sci ; 90(5): 2253-9, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-17430925

RESUMEN

The somatic cell count (SCC) is one of the international standards for monitoring milk quality, and it is a useful indicator of mastitis. The current reference method for determining the SCC in raw milk is direct microscopic analysis, but this method requires well-trained staff to maintain its accuracy and reproducibility. To overcome these inconveniences, we developed a portable system (the C-reader system) that utilizes the capillary flow of a microfluidic chamber by surface modification of the hydrophilicity. The microfluidic technology of disposable microchips allows for low consumption of reagents, and a combination of ready-to-use reagents makes the daily work easier. The repeatability test of the C-reader using 10 composite bovine milk samples satisfied the recommended values for SCC equipment. In addition, an acceptable accuracy level of the natural logarithmic-transformed SCC [ln(SCC/1,000): +/- 0.059 to 0.112] was achieved using composite raw milk samples and various somatic cell standard solutions from the American Eastern Laboratory and the Korean National Veterinary Research and Quarantine Service. After testing 875 composite milk samples, the C-reader showed a high correlation coefficient (R2 = 0.935 to 0.964) and a low mean difference value in log-transformed SCC (-0.088 to 0.004) compared with 3 automatic commercialized somatic cell counters (Fossomatic 4000, Somacount 150, and Somascope). In conclusion, the C-reader system is a new, easy-to-use automatic on-farm method with acceptable repeatability and accuracy for measuring SCC in large dairies and smaller laboratories.


Asunto(s)
Recuento de Células/veterinaria , Industria Lechera/instrumentación , Procedimientos Analíticos en Microchip/veterinaria , Leche/citología , Animales , Bovinos , Recuento de Células/instrumentación , Recuento de Células/métodos , Industria Lechera/métodos , Femenino , Dispositivos Laboratorio en un Chip , Mastitis Bovina/diagnóstico , Procedimientos Analíticos en Microchip/métodos , Reproducibilidad de los Resultados
2.
ASAIO J ; 45(3): 215-7, 1999.
Artículo en Inglés | MEDLINE | ID: mdl-10360726

RESUMEN

We developed an electrohydraulic ventricular assist device with magnetic coupling. The integrated system consists of a blood pump, a water conduit for pressure transmission, a bellows type pumping sac, an actuator for transforming the circular motion of a motor to the linear motion of a pusher plate attached to the pumping sac with magnetic coupling, and a controller. The purpose of the coupling was to prevent excessive sucking against the atrial wall. Number 21 Medtronic Hall (Irvine, CA) mechanical valves were used in the inflow and outflow ports of the blood pump. Maximum dynamic stroke volume was 48 ml, and against a mean afterload of 100 mm Hg, maximum pump output was 7 L/min. Chronic in vivo experiments were performed in three sheep, and during these evaluations the system showed no noticeable problems related to mechanical or electronic devices. When left atrial pressure decreased below 0 mm Hg, the magnetic coupling system decoupled the pumping sac and pusher plate with satisfactory reliability. The device was clinically applied in a postoperative patient with chronic dilating cardiomyopathy, and no significant device related problems ensued. These results prove that the electrohydraulic ventricular assist system with magnetic coupling is a suitable ventricular assist device.


Asunto(s)
Corazón Auxiliar , Magnetismo , Ensayo de Materiales , Animales , Presión Sanguínea , Gasto Cardíaco , Diseño de Equipo , Femenino , Hemoglobinas , Ovinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA