Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Dis Esophagus ; 26(1): 91-6, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22394249

RESUMEN

The purpose of this study is to apply combined multichannel intraluminal impedance and esophageal manometry (MII-EM) to test esophageal function during solid swallowing in a normal healthy population. We determined whether combined MII-EM with solid bolus is more sensitive than that with viscous bolus in the detection of motility abnormality. Eighteen healthy volunteers (11 men and 7 women; mean age 22 years, range 20-26 years) underwent combined MII-EM with a catheter containing four impedance-measuring segments and five solid-state pressure transducers. Each subject received 10 viscous and 10 solid materials. Tracings were analyzed manually for bolus presence time, total bolus transit time, contraction amplitude, duration, and onset velocity. Three hundred and sixty swallows including viscous and solid materials were analyzed. Contraction amplitude for the viscous swallows was higher at 20 cm above the lower esophageal sphincter (LES) (P= 0.049) but lower at 15 cm above the LES (P < 0.001). Duration of contractions for the solid swallows was longer at 15 cm (P= 0.002) and 10 cm above the LES (P= 0.011) compared with viscous swallows. The total bolus transit time for solid was significantly shorter than that for viscous boluses (6.8 vs. 7.7 seconds, P < 0.001). Bolus presence time appeared to be similar between viscous and solid boluses (except in the proximal esophagus). The percentage of swallows with ineffective peristalsis by manometry, as well as those with incomplete bolus transit by impedance, did not differ between viscous and solid swallows. The proportion of manometrically ineffective solid swallows with incomplete bolus transit was greater than that of viscous swallows (62.1% vs. 34.8%, P= 0.05). Application of solid boluses may potentially enhance diagnostic capability of esophageal function testing. Solid boluses can be regarded as a valuable complement to viscous boluses in the detection of esophageal motility abnormalities when applied with combined MII-EM.


Asunto(s)
Deglución/fisiología , Tránsito Gastrointestinal/fisiología , Peristaltismo/fisiología , Adulto , Impedancia Eléctrica , Femenino , Alimentos , Humanos , Masculino , Manometría/métodos , Valores de Referencia , Muestreo , Adulto Joven
2.
Br J Radiol ; 83(988): e83-5, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20335438

RESUMEN

CT-guided transthoracic lung biopsy is becoming a widely accepted procedure for the diagnosis of pulmonary lesions. The rate of severe complications following such a procedure has been reported. Of these complications, air embolism is the most likely to be fatal. We report a case of right coronary air embolism resulting in myocardial infarction after a CT-guided percutaneous needle biopsy of the lung. The patient died from underlying malignant disease 4 months later.


Asunto(s)
Biopsia con Aguja/efectos adversos , Vasos Coronarios , Embolia Aérea/etiología , Neoplasias Pulmonares/patología , Pulmón/patología , Infarto del Miocardio/etiología , Adulto , Aorta , Biopsia con Aguja/métodos , Embolia Aérea/diagnóstico por imagen , Resultado Fatal , Humanos , Masculino , Radiografía Intervencional , Tomografía Computarizada por Rayos X
3.
Br J Radiol ; 79(947): e187-9, 2006 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17065285

RESUMEN

The coexistence of multiple and synchronous primary neoplasms in the genitourinary system has only rarely been described in the literature. We present the case of a 78-year-old man with haematuria as the initial presentation, finally proven to be transitional cell carcinoma (TCC) combined with renal cell carcinoma (RCC). Intravenous urography (IVU), CT and arterial angiography studies revealed a space-occupying nodule at the right upper renal pelvicalyces showing mild enhancement with contrast medium. Another strong contrast medium enhancing exophytic tumour was found at the lower pole of kidney; there were hypodense foci and calcified components in this lesion. A right nephroureterectomy was performed. Pathological diagnosis was a papillary TCC and a clear cell type RCC. This is a rare case of combined renal malignancies diagnosed by imaging.


Asunto(s)
Carcinoma de Células Renales/diagnóstico por imagen , Carcinoma de Células Transicionales/diagnóstico por imagen , Neoplasias Renales/diagnóstico por imagen , Neoplasias Primarias Múltiples/diagnóstico por imagen , Anciano , Humanos , Masculino , Tomografía Computarizada por Rayos X
4.
Br J Radiol ; 79(942): 526-8, 2006 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16714757

RESUMEN

Penile lymphoma is extremely rare and secondary involvement of the penis by lymphoma may be due to retrograde spread or to direct extension from neighbouring organ. The appearance of penile lymphoma varies and can be mistaken for other soft tissue tumours. We report on a case with malignant lymphoma of the penis. MRI findings revealed soft-tissue mass of homogeneous isointensity around the middle to distal part of penis on T(1) weighted imaging and T(2) weighted imaging. It was well encapsulated, minimally enhanced and distinct from corpus cavernosum and corpus spongiosum.


Asunto(s)
Linfoma de Células B/diagnóstico , Neoplasias del Pene/diagnóstico , Anciano , Humanos , Imagen por Resonancia Magnética , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA