Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Artículo en Ruso | MEDLINE | ID: mdl-1509843

RESUMEN

The seroepidemiological survey of 400,000 persons aged 20-40 years and belonging to different AIDS risk groups, as well as blood donors, for the presence of antibodies to HIV has been carried out on the territory of Lithuania. This investigation has been made with the use of the assay systems "Antigen", "Peptoscreen" and "Vector" manufactured in the USSR, as well as commercial assay systems from foreign manufacturers, such as Du Pont de Nemours Inc., Organon N. V., Abbott Laboratories, Serodia. The comparison of the results thus obtained has revealed that high frequency of false positive results is characteristic of all assay systems under study, including immunoblotting. These data indicate that test systems based on different acting principles should be used for the detection of anti-HIV antibodies. For the first time a HIV-infected resident of Lithuania has been detected. The investigation carried out in Lithuania has shown that HIV infection is not widely spread in this region, but due to some objective reasons this does not preclude the necessity of the constant epidemiological surveillance of this infection throughout this territory in order to bar the way to this infection.


Asunto(s)
Síndrome de Inmunodeficiencia Adquirida/epidemiología , Síndrome de Inmunodeficiencia Adquirida/diagnóstico , Western Blotting , Reacciones Falso Positivas , Anticuerpos Anti-VIH/análisis , Humanos , Técnicas para Inmunoenzimas , Lituania/epidemiología
2.
Vestn Ross Akad Med Nauk ; (11-12): 15-20, 1992.
Artículo en Ruso | MEDLINE | ID: mdl-1284214

RESUMEN

Using a panel of sera from HIV-infected persons and donors, the authors showed that radioimmunoprecipitation assays compare favourably with immunoblotting assays. With radioimmunoprecipitation, cross reactions were observed between HIV-2 antigens and HIV-2 antibodies, and that the nature of cross reactivity differs from that observed with immunoblotting. Potentials of radioimmunoprecipitation assays as a confirmatory test for use with sera that have given indeterminate results in immunoblotting assays and contradictory results in enzyme immunoassays are examined.


Asunto(s)
Serodiagnóstico del SIDA/métodos , Infecciones por VIH/diagnóstico , VIH-1 , VIH-2 , Ensayo de Radioinmunoprecipitación/métodos , Síndrome de Inmunodeficiencia Adquirida/diagnóstico , Reacciones Cruzadas , Diagnóstico Diferencial , Estudios de Evaluación como Asunto , Técnica del Anticuerpo Fluorescente , Anticuerpos Anti-VIH/sangre , Antígenos VIH/sangre , VIH-1/inmunología , VIH-2/inmunología , Humanos , Immunoblotting , Técnicas para Inmunoenzimas , Radioinmunoensayo , Sensibilidad y Especificidad
4.
J Med Virol ; 27(1): 72-5, 1989 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-2466101

RESUMEN

Ten sera from healthy blood donors positive by enzyme-linked immunoadsorbent assay (ELISA) were studied by immunoblot assay using natural and recombinant proteins. They interacted only with p17 or p24 proteins but were nonreactive with a recombinant protein (RP 50), which carries antigenic determinants to p17 and p24. Reactions were not blocked by preincubation of sera with genetically engineered p17 and p24 or purified viral p24, indicating that some new epitopes were formed during the Western blot procedure. Recombinant gag-encoded protein is required for confirmation of human immunodeficiency virus (HIV) seropositivity.


Asunto(s)
Antígenos VIH/inmunología , VIH/inmunología , Proteínas de los Retroviridae/inmunología , Proteínas Virales , Western Blotting , Ensayo de Inmunoadsorción Enzimática , Epítopos/genética , Epítopos/inmunología , Reacciones Falso Positivas , Productos del Gen gag , Genes Virales , VIH/genética , Antígenos VIH/genética , Proteína p24 del Núcleo del VIH , Humanos , Sueros Inmunes/inmunología , Proteínas Recombinantes/genética , Proteínas Recombinantes/inmunología , Proteínas de los Retroviridae/genética , Productos del Gen gag del Virus de la Inmunodeficiencia Humana
5.
Vopr Virusol ; 33(6): 700-3, 1988.
Artículo en Ruso | MEDLINE | ID: mdl-3073570

RESUMEN

A recombinant antigen produced in CV-I cells infected with vaccinia virus vC5 carrying the HIV-I gag gene was used to test sera. This antigen (rp50) reacted with 95 serum specimens shown to have anticore antibodies by immunoblot based on natural HIV antigens. Six sera from blood donors positive in ELISA contained antibodies to p17, p24, or p55 by natural antigen-based blot. All these sera did not react with rp50. These patients did not belong to any known risk groups and showed no dynamics in the immunoblot pattern. We consider the reaction of their serum samples as false positive. We believe that the recombinant antigen rp50 may be used for verification of positive ELISA results.


Asunto(s)
Antígenos VIH/inmunología , Immunoblotting/métodos , Proteínas Recombinantes/inmunología , Síndrome de Inmunodeficiencia Adquirida/diagnóstico , Antígenos Virales/inmunología , Estudios de Evaluación como Asunto , Humanos , Técnicas para Inmunoenzimas , Recombinación Genética , Virus Vaccinia/inmunología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA