Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 23(5)2023 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-36904953

RESUMEN

Human action recognition (HAR) is one of the most active research topics in the field of computer vision. Even though this area is well-researched, HAR algorithms such as 3D Convolution Neural Networks (CNN), Two-stream Networks, and CNN-LSTM (Long Short-Term Memory) suffer from highly complex models. These algorithms involve a huge number of weights adjustments during the training phase, and as a consequence, require high-end configuration machines for real-time HAR applications. Therefore, this paper presents an extraneous frame scrapping technique that employs 2D skeleton features with a Fine-KNN classifier-based HAR system to overcome the dimensionality problems.To illustrate the efficacy of our proposed method, two contemporary datasets i.e., Multi-Camera Action Dataset (MCAD) and INRIA Xmas Motion Acquisition Sequences (IXMAS) dataset was used in experiment. We used the OpenPose technique to extract the 2D information, The proposed method was compared with CNN-LSTM, and other State of the art methods. Results obtained confirm the potential of our technique. The proposed OpenPose-FineKNN with Extraneous Frame Scrapping Technique achieved an accuracy of 89.75% on MCAD dataset and 90.97% on IXMAS dataset better than existing technique.


Asunto(s)
Redes Neurales de la Computación , Reconocimiento de Normas Patrones Automatizadas , Humanos , Reconocimiento de Normas Patrones Automatizadas/métodos , Algoritmos , Memoria a Largo Plazo , Actividades Humanas , Esqueleto
2.
Front Neurosci ; 16: 955464, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36389219

RESUMEN

In resting tremor, the body part is in complete repose and often dampens or subsides entirely with action. The most frequent cause of resting tremors is known as idiopathic Parkinson's disease (PD). For examination, neurologists of patients with PD include tests such as finger-to-nose tests, walking back and forth in the corridor, and the pull test. This evaluation is focused on Unified Parkinson's disease rating scale (UPDRS), which is subjective as well as based on some daily life motor activities for a limited time frame. In this study, severity analysis is performed on an imbalanced dataset of patients with PD. This is the reason why the classification of various data containing imbalanced class distribution has endured a notable drawback of the performance achievable by various standard classification learning algorithms. In this work, we used resampling techniques including under-sampling, over-sampling, and a hybrid combination. Resampling techniques are incorporated with renowned classifiers, such as XGBoost, decision tree, and K-nearest neighbors. From the results, it is concluded that the Over-sampling method performed much better than under-sampling and hybrid sampling techniques. Among the over-sampling techniques, random sampling has obtained 99% accuracy using XGBoost classifier and 98% accuracy using the decision tree. Besides, it is observed that different resampling methods performed differently with various classifiers.

3.
Sensors (Basel) ; 22(2)2022 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-35062598

RESUMEN

The incidence of diabetes is increasing at an alarming rate, and regular glucose monitoring is critical in order to manage diabetes. Currently, glucose in the body is measured by an invasive method of blood sugar testing. Blood glucose (BG) monitoring devices measure the amount of sugar in a small sample of blood, usually drawn from pricking the fingertip, and placed on a disposable test strip. Therefore, there is a need for non-invasive continuous glucose monitoring, which is possible using a sweat sensor-based approach. As sweat sensors have garnered much interest in recent years, this study attempts to summarize recent developments in non-invasive continuous glucose monitoring using sweat sensors based on different approaches with an emphasis on the devices that can potentially be integrated into a wearable platform. Numerous research entities have been developing wearable sensors for continuous blood glucose monitoring, however, there are no commercially viable, non-invasive glucose monitors on the market at the moment. This review article provides the state-of-the-art in sweat glucose monitoring, particularly keeping in sight the prospect of its commercialization. The challenges relating to sweat collection, sweat sample degradation, person to person sweat amount variation, various detection methods, and their glucose detection sensitivity, and also the commercial viability are thoroughly covered.


Asunto(s)
Técnicas Biosensibles , Dispositivos Electrónicos Vestibles , Glucemia , Automonitorización de la Glucosa Sanguínea , Glucosa , Humanos , Sudor
4.
Sensors (Basel) ; 21(17)2021 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-34502679

RESUMEN

The COVID-19 pandemic has wreaked havoc globally and still persists even after a year of its initial outbreak. Several reasons can be considered: people are in close contact with each other, i.e., at a short range (1 m), and the healthcare system is not sufficiently developed or does not have enough facilities to manage and fight the pandemic, even in developed countries such as the USA and the U.K. and countries in Europe. There is a great need in healthcare for remote monitoring of COVID-19 symptoms. In the past year, a number of IoT-based devices and wearables have been introduced by researchers, providing good results in terms of high accuracy in diagnosing patients in the prodromal phase and in monitoring the symptoms of patients, i.e., respiratory rate, heart rate, temperature, etc. In this systematic review, we analyzed these wearables and their need in the healthcare system. The research was conducted using three databases: IEEE Xplore®, Web of Science®, and PubMed Central®, between December 2019 and June 2021. This article was based on the PRISMA guidelines. Initially, 1100 articles were identified while searching the scientific literature regarding this topic. After screening, ultimately, 70 articles were fully evaluated and included in this review. These articles were divided into two categories. The first one belongs to the on-body sensors (wearables), their types and positions, and the use of AI technology with ehealth wearables in different scenarios from screening to contact tracing. In the second category, we discuss the problems and solutions with respect to utilizing these wearables globally. This systematic review provides an extensive overview of wearable systems for the remote management and automated assessment of COVID-19, taking into account the reliability and acceptability of the implemented technologies.


Asunto(s)
COVID-19 , Dispositivos Electrónicos Vestibles , Humanos , Pandemias , Reproducibilidad de los Resultados , SARS-CoV-2
5.
Sensors (Basel) ; 21(3)2021 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-33540570

RESUMEN

Parkinson's disease patients face numerous motor symptoms that eventually make their life different from those of normal healthy controls. Out of these motor symptoms, tremor and bradykinesia, are relatively prevalent in all stages of this disease. The assessment of these symptoms is usually performed by traditional methods where the accuracy of results is still an open question. This research proposed a solution for an objective assessment of tremor and bradykinesia in subjects with PD (10 older adults aged greater than 60 years with tremor and 10 older adults aged greater than 60 years with bradykinesia) and 20 healthy older adults aged greater than 60 years. Physical movements were recorded by means of an AWEAR bracelet developed using inertial sensors, i.e., 3D accelerometer and gyroscope. Participants performed upper extremities motor activities as adopted by neurologists during the clinical assessment based on Unified Parkinson's Disease Rating Scale (UPDRS). For discriminating the patients from healthy controls, temporal and spectral features were extracted, out of which non-linear temporal and spectral features show greater difference. Both supervised and unsupervised machine learning classifiers provide good results. Out of 40 individuals, neural net clustering discriminated 34 individuals in correct classes, while the KNN approach discriminated 91.7% accurately. In a clinical environment, the doctor can use the device to comprehend the tremor and bradykinesia of patients quickly and with higher accuracy.


Asunto(s)
Hipocinesia , Monitoreo Fisiológico , Enfermedad de Parkinson , Dispositivos Electrónicos Vestibles , Anciano , Humanos , Hipocinesia/diagnóstico , Movimiento , Enfermedad de Parkinson/diagnóstico , Temblor/diagnóstico
6.
Sensors (Basel) ; 20(9)2020 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-32397516

RESUMEN

Prevalence of neurocognitive diseases in adult patients demands the use of wearable devices to transform the future of mental health. Recent development in wearable technology proclaimed its use in diagnosis, rehabilitation, assessment, and monitoring. This systematic review presents the state of the art of wearables used by Parkinson's disease (PD) patients or the patients who are going through a neurocognitive disorder. This article is based on PRISMA guidelines, and the literature is searched between January 2009 to January 2020 analyzing four databases: PubMed, IEEE Xplorer, Elsevier, and ISI Web of Science. For further validity of articles, a new PEDro-inspired technique is implemented. In PEDro, five statistical indicators were set to classify relevant articles and later the citations were also considered to make strong assessment of relevant articles. This led to 46 articles that met inclusion criteria. Based on them, this systematic review examines different types of wearable devices, essential in improving early diagnose and monitoring, emphasizing their role in improving the quality of life, differentiating the various fitness and gait wearable-based exercises and their impact on the regression of disease and on the motor diagnosis tests and finally addressing the available wearable insoles and their role in rehabilitation. The research findings proved that sensor based wearable devices, and specially instrumented insoles, help not only in monitoring and diagnosis but also in tracking numerous exercises and their positive impact towards the improvement of quality of life among different Parkinson and neurocognitive patients.


Asunto(s)
Trastornos Neurocognitivos/rehabilitación , Enfermedad de Parkinson/rehabilitación , Dispositivos Electrónicos Vestibles , Adulto , Marcha , Humanos , Calidad de Vida
7.
Sensors (Basel) ; 19(21)2019 Oct 23.
Artículo en Inglés | MEDLINE | ID: mdl-31652753

RESUMEN

This paper deals with the fractional order control for the complex systems, hand exoskeleton and sensors, that monitor and control the human behavior. The control laws based on physical significance variables, for fractional order models, with delays or without delays, are proposed and discussed. Lyapunov techniques and the methods that derive from Yakubovici-Kalman-Popov lemma are used and the frequency criterions that ensure asymptotic stability of the closed loop system are inferred. An observer control is proposed for the complex models, exoskeleton and sensors. The asymptotic stability of the system, exoskeleton hand-observer, is studied for sector control laws. Numerical simulations for an intelligent haptic robot-glove are presented. Several examples regarding these models, with delays or without delays, by using sector control laws or an observer control, are analyzed. The experimental platform is presented.


Asunto(s)
Mano/fisiología , Modelos Teóricos , Dispositivo Exoesqueleto , Humanos , Dispositivos Electrónicos Vestibles
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA