Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Pediatr ; 239: 150-154.e1, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34453917

RESUMEN

OBJECTIVE: To characterize respiratory function monitor (RFM) measurements of sustained inflations and intermittent positive pressure ventilation (IPPV) delivered noninvasively to infants in the Sustained Aeration of Infant Lungs (SAIL) trial and to compare vital sign measurements between treatment arms. STUDY DESIGN: We analyzed RFM data from SAIL participants at 5 trial sites. We assessed tidal volumes, rates of airway obstruction, and mask leak among infants allocated to sustained inflations and IPPV, and we compared pulse rate and oxygen saturation measurements between treatment groups. RESULTS: Among 70 SAIL participants (36 sustained inflations, 34 IPPV) with RFM measurements, 40 (57%) were spontaneously breathing prior to the randomized intervention. The median expiratory tidal volume of sustained inflations administered was 5.3 mL/kg (IQR 1.1-9.2). Significant mask leak occurred in 15% and airway obstruction occurred during 17% of sustained inflations. Among 34 control infants, the median expiratory tidal volume of IPPV inflations was 4.3 mL/kg (IQR 1.3-6.6). Mask leak was present in 3%, and airway obstruction was present in 17% of IPPV inflations. There were no significant differences in pulse rate or oxygen saturation measurements between groups at any point during resuscitation. CONCLUSION: Expiratory tidal volumes of sustained inflations and IPPV inflations administered in the SAIL trial were highly variable in both treatment arms. Vital sign values were similar between groups throughout resuscitation. Sustained inflation as operationalized in the SAIL trial was not superior to IPPV to promote lung aeration after birth in this study subgroup. TRIAL REGISTRATION: Clinicaltrials.gov: NCT02139800.


Asunto(s)
Presión de las Vías Aéreas Positiva Contínua/métodos , Ventilación con Presión Positiva Intermitente/métodos , Resucitación/métodos , Presión de las Vías Aéreas Positiva Contínua/efectos adversos , Femenino , Edad Gestacional , Humanos , Recien Nacido Extremadamente Prematuro , Recién Nacido , Recien Nacido Prematuro , Ventilación con Presión Positiva Intermitente/efectos adversos , Masculino , Pruebas de Función Respiratoria
2.
J Pediatr ; 167(3): 545-50.e1-2, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26144575

RESUMEN

OBJECTIVE: To determine the efficacy and safety of automated adjustment of the fraction of inspired oxygen (FiO2) in maintaining arterial oxygen saturation (SpO2) within a higher (91%-95%) and a lower (89%-93%) target range in preterm infants. STUDY DESIGN: Eighty preterm infants (gestational age [median]: 26 weeks, age [median] 18 days) on noninvasive (n = 50) and invasive (n = 30) respiratory support with supplemental oxygen, were first randomized to one of the SpO2 target ranges and then treated with automated FiO2 (A-FiO2) and manual FiO2 (M-FiO2) oxygen control for 24 hours each, in random sequence. RESULTS: The percent time within the target range was higher during A-FiO2 compared with M-FiO2 control. This effect was more pronounced in the lower SpO2 target range (62 ± 17% vs 54 ± 16%, P < .001) than in the higher SpO2 target range (62 ± 17% vs 58 ± 15%, P < .001). The percent time spent below the target or in hypoxemia (SpO2 <80%) was consistently reduced during A-FiO2, independent of the target range. The time spent above the target range or at extreme hyperoxemia (SpO2 >98%) was only reduced during A-FiO2 when targeting the lower SpO2 range (89%-93%). These outcomes did not differ between infants on noninvasive and invasive respiratory support. Manual adjustments were significantly reduced during A-FiO2 control. CONCLUSIONS: A-FiO2 control improved SpO2 targeting across different SpO2 ranges and reduced hypoxemia in preterm infants on noninvasive and invasive respiratory support. TRIAL REGISTRATION: ISRCTN 56626482.


Asunto(s)
Oximetría/métodos , Oxígeno/sangre , Respiración Artificial/métodos , Canadá , Estudios Cruzados , Europa (Continente) , Femenino , Humanos , Recién Nacido , Recien Nacido Prematuro , Unidades de Cuidado Intensivo Neonatal , Masculino , Oxígeno/uso terapéutico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA