Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Nanoscale ; 10(35): 16556-16561, 2018 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-30140831

RESUMEN

The opto-mechanical control of the heat generated by an amorphous arrangement of homogenously distributed gold nanoparticles (AuNPs), excited by an external laser source, is investigated. Application of a macroscopic mechanical strain to the biocompatible elastomeric tape supporting the particles leads to a nanoscale modification of their mutual inter-distance. The resulting strong variation of the particles near-field coupling gives rise to a macroscopic variation of the photo-generated heat. A fine control of the amount of generated heat is thus possible by stretching the initially isotropic sample by only a few percent. Due to the anisotropy of the stretching procedure, the plasmon band shift and thus the heat generation becomes strongly polarization-dependent. A model of the system based on Mie theory is implemented by using a finite element method. Under optical excitation, two configurations of AuNPs, representing the same cluster of particles at rest and under stretching, show a relative increase of temperature that is in good quantitative agreement with experimental data, if normalized to the number of involved particles. This system realizes for the first time an opto-mechanical control of the temperature at the nanoscale which holds promise for the development of optically-active thermal patches, usable for biomedical applications, and flexible platforms for microfluidics and lab-on-a-chip devices.

2.
Soft Matter ; 13(8): 1728-1736, 2017 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-28165098

RESUMEN

We have demonstrated colorimetric and fluorescence detection of a peptide, melittin, based on polydiacetylene (PDA) made of 1,2-bis(10,12-tricosadiynoyl)-sn-glycero-3-phosphocholine (DC(8,9)PC). The PDA used in this work has a phosphocholine headgroup, which mimics peptide-cell membrane interactions better than the conventional PDAs with carboxyl headgroups. The dose curve (colorimetric response vs. melittin concentration) showed a half maximum response at the melittin concentration of 0.1 mg ml-1, which is similar to that reported in traditional PDA assays. It suggests that the replacement of the headgroup was achieved without sacrificing the sensitivity. From the dose curve, the Hill coefficient was extracted as αHill = 2.1. The value is in agreement with the results from previous melittin studies with phospholipids, which reflects the benefit of having a biologically relevant headgroup. In addition, we found an unexpectedly slow spectral change when DC(8,9)PC-PDA was incubated with melittin. The origin of the time-dependent signal was studied by combining UV/VIS spectroscopy, fluorescence spectroscopy and dynamic light scattering.

3.
Langmuir ; 31(48): 13221-9, 2015 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-26575589

RESUMEN

Elongated plasmonic nanoparticles show superior optical properties when compared to spherical ones. Facile, versatile and cost-effective bottom-up approaches for fabrication of anisotropic nanoparticles in solution have been developed. However, fabrication of 2-D plasmonic templates from elongated nanoparticles with spatial arrangement at the surface is still a challenge. We used controlled seed-mediated growth in the presence of porous and functionalized surface of flexible polydimethylsiloxane (PDMS) templates to provide directional growth and formation of elongated gold nanoparticles (AuNPs). Atomic force microscopy (AFM) and spectroscopy revealed embedding of the particles within the functionalized porous surface of PDMS. Nanoparticles shapes were observed with transmission electron microscope (TEM), UV-Vis spectroscopy, and X-ray powder diffraction (XRPD) measurements, which revealed an overall orientation of particles at the surface. Anisotropic and oriented particles on a flexible substrate are of interest for sensing applications.

4.
Rev Sci Instrum ; 84(10): 103907, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24182129

RESUMEN

The development of a volumetric apparatus (also known as a Sieverts' apparatus) for accurate and reliable hydrogen adsorption measurement is shown. The instrument minimizes the sources of systematic errors which are mainly due to inner volume calibration, stability and uniformity of the temperatures, precise evaluation of the skeletal volume of the measured samples, and thermodynamical properties of the gas species. A series of hardware and software solutions were designed and introduced in the apparatus, which we will indicate as f-PcT, in order to deal with these aspects. The results are represented in terms of an accurate evaluation of the equilibrium and dynamical characteristics of the molecular hydrogen adsorption on two well-known porous media. The contribution of each experimental solution to the error propagation of the adsorbed moles is assessed. The developed volumetric apparatus for gas storage capacity measurements allows an accurate evaluation over a 4 order-of-magnitude pressure range (from 1 kPa to 8 MPa) and in temperatures ranging between 77 K and 470 K. The acquired results are in good agreement with the values reported in the literature.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA