Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
J Sports Sci ; 42(11): 971-980, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39082736

RESUMEN

Recently, a variety of technical approaches in world-class pole-vaulters' behaviour have been observed. The aim of this study was to investigate the presence of subgroups using different technical approaches and to compare biomechanical performance differences. Biomechanical analysis of performances over 5.00 metres from 99 athletes were clustered with K-means methodology based on the relative position of the top hand at take-off and the direction of the top of the pole from take-off to the maximal pole bending. Analysis revealed four subgroups that were distinguished by higher and lower direction angle and relative position values. Despite differences in technique, the analysis did not reveal significant differences between these four groups in performance, take-off speed, or athlete anthropometrics. Nevertheless, these clusters showcased variations in pole-athlete interactions and pole bending, suggesting different strategies and physical requirements associated with each approach. Cluster 2 characterised the classical technique with a high direction angle and a take-off position close to the vertical plane. Cluster 4 displayed a technique with a low take-off angle, suggesting the influence of athletes like Lavillenie, in deviating from the conventional model. Understanding and categorising athletes based on their preferred technique can aid coaches in providing tailored instructions, leading to performance improvements.


Asunto(s)
Rendimiento Atlético , Conducta Competitiva , Humanos , Fenómenos Biomecánicos , Rendimiento Atlético/fisiología , Masculino , Conducta Competitiva/fisiología , Análisis por Conglomerados , Destreza Motora/fisiología , Femenino , Equipo Deportivo , Adulto Joven , Atletismo/fisiología , Adulto , Antropometría , Estudios de Tiempo y Movimiento , Análisis y Desempeño de Tareas
2.
J Hum Kinet ; 87: 41-49, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37559772

RESUMEN

The purpose of the study was to identify the interaction of step characteristics, along with the direction and magnitude of their asymmetry of elite male and female pole vaulters between successful and failed attempts. It was hypothesized that step characteristics and the magnitude of asymmetry between the two legs would interact with the outcome of the attempt. The approach runs of 12 pole vaulters (7 males, 5 females) were recorded during an indoor international competition. The leg used by the athlete for taking-off was defined as the non-pole-carrying leg, while the other was the pole-carrying leg. Using spatiotemporal information obtained from recordings with a panning camera (300 fps), the last steps of each athlete's approach run were analyzed for length, frequency, average velocity, and inter-limb asymmetry. There was no inter-limb difference (p > 0.05) in the absolute values of step length or step velocity between successful and failed attempts. However, the pole-carrying leg presented significantly (p < 0.05) higher step frequency values at the failed attempts. There was no significant difference (p > 0.05) in asymmetry values for step length, frequency, and average velocity between successful and failed attempts. Although step velocity remained unaffected, failed attempts were characterized by a perturbation in the interaction of step frequency and step length. The present findings suggest that although high velocity at the final phase of the approach is essential, it is not the sole determining factor for a successful attempt.

3.
Ergonomics ; 66(12): 2012-2024, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36745493

RESUMEN

The study aimed to examine physiological responses of firefighters performing a firefighting simulation test (FST) and to determine the relationship between physical fitness parameters and FST performance. Aerobic fitness, muscular strength, muscular endurance, and anaerobic capabilities were evaluated in 37 firefighters (21-profesionals and 16-volunteers firefighters). Furthermore, participants carried out the FST during which we measured performance, respiratory gas exchange, heart rate (HR), perceived exertion and blood lactate concentrations. Males were significantly faster than females for all tasks of the FST (p < 0.01); however, final performance score (16.5 ± 2.9 and 14.5 ± 2.6 points for males and females, respectively), HR (94.0 ± 2.0% and 93.7 ± 2.3% of HRmax) and perceived exertion (8.1 ± 0.9 and 7.1 ± 1.3) were not significantly different. Prediction of FST performance by LASSO regression revealed a model that included mainly aerobic capacity and maximal strength. In conclusion, FST challenged both aerobic and anaerobic energy metabolisms for both males and females and requires various physiological abilities to perform. Practitioner Summary: For the safety of firefighters and victims, firefighters must meet minimum physical requirements. 37 firefighters performed physical tests and a new firefighting test implemented for the recruitment of firefighters in France. The results revealed that this test is strenuous and that performance is associated with cardiorespiratory fitness and muscular strength. Abbreviations: V̇O2: oxygen consumption; V̇CO2: carbon dioxyde production; V̇E: expired ventilation; RER: respiratory exchange ratio; FST: firefighting simulation test; MAS: maximal aerobic speed; HR: heart rate; RPE: rating of perceived exertion; MVC: maximum voluntary contraction; IMTP: isometric mid-thigh pull; TTE: time to exhaustion; Ppeak: peak power; Pmean: mean power; LASSO: least absolute shrinkage and selection operator; La-: blood lactate concentration.


Asunto(s)
Prueba de Esfuerzo , Bomberos , Masculino , Femenino , Humanos , Prueba de Esfuerzo/métodos , Aptitud Física/fisiología , Fuerza Muscular/fisiología , Rendimiento Físico Funcional , Consumo de Oxígeno , Ácido Láctico , Frecuencia Cardíaca , Esfuerzo Físico/fisiología
4.
Sports (Basel) ; 10(11)2022 Nov 09.
Artículo en Inglés | MEDLINE | ID: mdl-36355824

RESUMEN

Trail running (TR) is performed in a natural environment, including various ranges of slopes where maximal oxygen consumption is a major contributor to performance. The aim of this study is to investigate the validity of tests performed in uphill conditions named the "IncremenTrail" (IncT), based on the incremental ascending speed (AS) to evaluate trail runners' cardiorespiratory parameters. IncT protocol included a constant gradient slope set at 25% during the whole test; the starting speed was 500 m·h-1 (25% slope and 2.06 km·h-1) and increased by 100 m·h-1 every minute (0.41 km·h-1). Twenty trail runner specialists performed the IncT and a supramaximal exercise bout to exhaustion with intensity set at 105% of maximal AS (Tlim). Oxygen consumption, breathing frequency, ventilation, respiratory exchange ratio (RER), and heart rate were continuously recorded during the exercises. The blood lactate concentration and rate of perceived exertion were collected at the end of the exercises. During the IncT test, 16 athletes (80%) reached a plateau of maximal oxygen uptake (65.5 ± 7.6 mL·kg-1·min-1), 19 athletes (95%) reached RER values over 1.10 (1.12 ± 0.02) and all the athletes achieved blood lactate concentration over 8.0 mmol·L-1 (17.1 ± 3.5 mmol·L-1) and a maximal heart rate ≥90% of the theoretical maximum (185 ± 11 bpm). Maximal values were not significantly different between IncT and Tlim. In addition, ventilatory thresholds could be determined for all runners with an associated AS. IncT provided a suitable protocol to evaluate trail runners' cardiorespiratory limitations and allowed us to obtain specific intensities based on the ascending speed useful for training purposes in specific conditions.

5.
Artículo en Inglés | MEDLINE | ID: mdl-36231513

RESUMEN

Uphill running induces a higher physiological demand than level conditions. Although many studies have investigated this locomotion from a psychological point of view, there is no clear position on the effects of the slope on the physiological variables during an incremental running test performed on a slope condition. The existing studies have heterogeneous designs with different populations or slopes and have reported unclear results. Some studies observed an increase in oxygen consumption, whereas it remained unaffected in others. The aim of this study is to investigate the effect of a slope on the oxygen consumption, breathing frequency, ventilation and heart rate during an incremental test performed on 0, 15, 25 and 40% gradient slopes by specialist trail runners. The values are compared at the first and second ventilatory threshold and exhaustion. A one-way repeated measures ANOVA, with a Bonferroni post-hoc analysis, was used to determine the effects of a slope gradient (0, 15, 25 and 40%) on the physiological variables. Our study shows that all the variables are not affected in same way by the slopes during the incremental test. The heart rate and breathing frequency did not differ from the level condition and all the slope gradients at the ventilatory thresholds or exhaustion. At the same time, the ventilation and oxygen consumption increased concomitantly with the slope (p < 0.001) in all positions. The post-hoc analysis highlighted that the ventilation significantly increased between each successive gradient (0 to 15%, 15% to 25% and 25% to 40%), while the oxygen consumption stopped increasing at the 25% gradient. Our results show that the 25 and 40% gradient slopes allow the specialist trail runners to reach the highest oxygen consumption level.


Asunto(s)
Prueba de Esfuerzo , Carrera , Prueba de Esfuerzo/métodos , Frecuencia Cardíaca/fisiología , Consumo de Oxígeno/fisiología , Respiración , Carrera/fisiología
6.
Sensors (Basel) ; 22(1)2022 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-35009945

RESUMEN

A large number of power meters have become commercially available during the last decades to provide power output (PO) measurement. Some of these power meters were evaluated for validity in the literature. This study aimed to perform a review of the available literature on the validity of cycling power meters. PubMed, SPORTDiscus, and Google Scholar have been explored with PRISMA methodology. A total of 74 studies have been extracted for the reviewing process. Validity is a general quality of the measurement determined by the assessment of different metrological properties: Accuracy, sensitivity, repeatability, reproducibility, and robustness. Accuracy was most often studied from the metrological property (74 studies). Reproducibility was the second most studied (40 studies) property. Finally, repeatability, sensitivity, and robustness were considerably less studied with only 7, 5, and 5 studies, respectively. The SRM power meter is the most used as a gold standard in the studies. Moreover, the number of participants was very different among them, from 0 (when using a calibration rig) to 56 participants. The PO tested was up to 1700 W, whereas the pedalling cadence ranged between 40 and 180 rpm, including submaximal and maximal exercises. Other exercise conditions were tested, such as torque, position, temperature, and vibrations. This review provides some caveats and recommendations when testing the validity of a cycling power meter, including all of the metrological properties (accuracy, sensitivity, repeatability, reproducibility, and robustness) and some exercise conditions (PO range, sprint, pedalling cadence, torque, position, participant, temperature, vibration, and field test).


Asunto(s)
Ciclismo , Prueba de Esfuerzo , Ejercicio Físico , Humanos , Reproducibilidad de los Resultados , Torque
7.
Sensors (Basel) ; 22(2)2022 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-35062429

RESUMEN

This paper aims to provide a review of the electrically assisted bicycles (also known as e-bikes) used for recovery of the rider's physical and physiological information, monitoring of their health state, and adjusting the "medical" assistance accordingly. E-bikes have proven to be an excellent way to do physical activity while commuting, thus improving the user's health and reducing air pollutant emissions. Such devices can also be seen as the first step to help unhealthy sedentary people to start exercising with reduced strain. Based on this analysis, the need to have e-bikes with artificial intelligence (AI) systems that recover and processe a large amount of data is discussed in depth. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines were used to complete the relevant papers' search and selection in this systematic review.


Asunto(s)
Inteligencia Artificial , Ciclismo , Accidentes de Tránsito , Electricidad , Humanos , Transportes
8.
Sports Biomech ; : 1-13, 2021 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-34664541

RESUMEN

This study compared changes in the energy-time profiles in pole vaulting using several body models. Two-dimensional kinematics were collected from 20 successful vaults (5.20-6.01 m) performed by 10 athletes during a national meet. The linear and angular kinetic, potential, and total mechanical energy-time profiles were obtained from three pole vaulter models composed of 12, 5, and 3 segments (M12, M5, and M3, respectively), as well as calculated and approximated centre of mass models. One-dimensional statistical parametric mapping was used to compare these energy-time profiles from the models, while agreements of discrete energy parameters were assessed. For all the studied energy-time profiles, there was a main effect (0.05 < p < 0.001) of the models, but pairwise comparisons showed that M5 presented the lowest differences with M12 in comparison with the other models (M3 and approximated centre of mass models). In addition, M5 showed better agreement (lower bias and small effect size) with M12 for the studied energy parameters compared to the other models. Therefore, M5 may be a reliable option to simplify the body model and speed up the computation of the energy-time profiles of the pole vaulter.

9.
Int J Sports Physiol Perform ; 15(9): 1340-1343, 2020 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-32887849

RESUMEN

PURPOSE: To study the consequences of a fatiguing ultratrail run of 6 hours on self-optimizing capability during uphill and downhill (DR) running. METHODS: The authors collected temporal stride kinematics and metabolic data in 8 (experimental group) male runners before and after the ultratrail run and in 6 (control group) male ultramarathon runners who did not run but stayed awake and performed normal, daily physical activities avoiding strenuous exercises over the 6-hour period. For each subject, preferred and optimal stride frequencies were measured, where stride frequency was systematically varied above and below the preferred one (±4% and ±8%) while running 3 conditions on level, 5% uphill, or 5% DR in a randomized order. RESULTS: Preferred and optimal stride frequencies across grade, group, and time showed no significant differences (P ≥ .184). Metabolic cost and the energetically optimum metabolic cost showed a grade × group × time interaction (P ≥ .011), with an ∼11% increase in the 2 variables only during the DR bouts (P ≥ .037). CONCLUSIONS: Despite maintaining similar dynamics of stride frequency adjustments during the DR bout, the experimental group was not able to optimize its gait. This suggests that the DR section of ultratrail runs can introduce a perturbing factor in the runners' optimization process, highlighting the need for incorporating DR bouts in the training programs of ultratrail runners to minimize the deleterious effects of DR on the energetically optimal gait.

10.
J Strength Cond Res ; 34(5): 1440-1447, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32329992

RESUMEN

Manouvrier, C, Cassirame, J, and Ahmaidi, S. Sensitivity of the footeval test to different training modes. J Strength Cond Res 34(5): 1440-1447, 2020-The aim of this study is to assess the impact of preseason training and more specifically about different training modality to Footeval test. This study also compares those sensibility with classic test, Vameval. A total of 36 young elite players' performance were split in 3 groups to perform 2 times a week a specific complements training: generic (GENERIC), small-sided game (SSG), and technical (TECH). After 4 weeks with training intervention, all players improved their performance to Footeval and Vameval tests. Regarding improvement, we noted that each training complement obtained different magnitude of modification. For all groups, Footeval increase was more important than Vameval. Small-sided game obtained highest improvement to Footeval (15 ± 1.8%) but lowest to Vameval (5 ± 0.9%). Oppositely, GENERIC and TECH groups obtained highest improvement to Vameval test (8 ± 1.4 and 8 ± 2.0%) but lower modification to Footeval (11 ± 2.2 and 16 ± 2.3%), respectively. Even if we removed the effect of maximum aerobic speed increase, SSG obtains better improvement than other training modality to Footeval.


Asunto(s)
Rendimiento Atlético , Prueba de Esfuerzo , Adolescente , Capacidad Cardiovascular , Humanos , Masculino , Consumo de Oxígeno , Carrera , Fútbol
11.
Int J Sports Med ; 40(7): 462-467, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31189190

RESUMEN

This study assessed the validity of a photoplethysmographic heart rate (HR) monitor, the Polar OH1 in various sports performed in ecological conditions: running, cycling, soccer, kayaking, walking, tennis and fitness. Seventy trained athletes (56 males, 14 females) wore the Polar OH1 armband and the H7 chest belt during training. A total of 390 h and 38 min of recording were compared using a 20-bpm window to assess data quality, and Bland-Altman agreements and ICC analyses were used to test accuracy. Linear regression analyses evaluated the HR accuracy and correlation with skin tone. Training loads (TRIMPs) were compared for each session. Reliability was high for endurance sports (>99%) and lower for sports involving arm movements (92~95%). Biases were slightly negative for all sports, whereas widths of limits of agreement varied from 7-20bpm. Bland-Altman agreements were all under 5% except tennis, kayak and fitness. HR accuracy was positively correlated to skin tone (p<0.05). Finally, TRIMPs from the OH1 device were inferior to criterion's (except walking and soccer), within a 3% range from reference. Hence, OH1 represents a valid tool to monitor instantaneous HR and training load, especially for endurance sports.


Asunto(s)
Frecuencia Cardíaca , Monitoreo Fisiológico/instrumentación , Acondicionamiento Físico Humano , Resistencia Física/fisiología , Deportes/fisiología , Adolescente , Brazo/fisiología , Femenino , Humanos , Masculino , Dispositivos Electrónicos Vestibles , Adulto Joven
12.
J Sci Med Sport ; 22(9): 1054-1058, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31029549

RESUMEN

OBJECTIVES: At a given running speed, humans naturally endeavor to achieve an optimal stride frequency that minimizes metabolic cost. Research has suggested that runners select this near optimal stride frequency in some process of self-optimization even during fatiguing tasks up to 1-h of high-intensity running. Here, we studied whether runners demonstrate a similar self-optimizing capability after an ultramarathon of 6 h. DESIGN: Controlled pre-post study. METHOD: We collected temporal stride kinematics and metabolic data in nine (experimental group) male runners before and after 6 h of running and in six (control group) male ultramarathon runners who did not run, but stayed awake and performed normal, daily physical activities avoiding strenuous exercises over the 6-h period. For each participant, preferred and optimal stride frequencies were measured, where stride frequency was systematically varied above and below PSF (±4% and ±8%). RESULTS: Preferred and optimal stride frequencies across time and group showed no significant differences (p ≥ 0.276). Furthermore, neither the overall relationship between metabolic cost and stride frequency, nor the energetically optimal stride frequency changed substantially after several hours of running. CONCLUSIONS: Similar dynamics of stride frequency adjustments in the experimental group occurred as those found in a non-fatigued state. This suggests that after an ultramarathon of 6 h, runners were still able to optimize their gait, and automatically adjust it in order to converge on the energetically optimal gait.


Asunto(s)
Metabolismo Energético , Fatiga/metabolismo , Marcha , Carrera/fisiología , Adulto , Fenómenos Biomecánicos , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
13.
Artículo en Inglés | MEDLINE | ID: mdl-33344944

RESUMEN

Background: Pole vault is a highly demanding sport where many physical and technical requirements are engaged in performance process. Considering level of energy transferred from athlete's horizontal speed to the pole during pole bending, we can imagine that associated musculoskeletal tensions, in addition to trials accumulation, can increase the risk of (specific) injuries. Given the multiple morphological, physical and technical characteristics of vaulters and ways of pole vaulting, we can hypothesis that some patterns of pole vaults can lead to higher injury risk than others. Aim: To analyze the potential association between the biomechanical patterns of pole vault and the history of injuries. Method: We conducted a study over national-level pole vaulters including the prospective collection of pole vault biomechanical data during competition at the national elite indoor championship and youth national indoor championship (U17 and U20), associated with the retrospective collection of their injuries during the 12 preceding months through an online questionnaire. Results: Among the 88 pole vaulters participating in these championships, 62 (70.5%) accepted to participated in this study, and their pole vault biomechanical and injury data were collected. 77.4% reported having presented at least one injury during the 12 preceding months. One biomechanical parameter related to the take-off phase (lower H2, i.e., height of the grip (superior) hand from the ground when the athlete subsequently took off from the ground) and some biomechanical parameters related to the terminal phase of the run-up phase (higher Spd [i.e., speed between 10 and 5 meters to the box), SLadj (last stride adjustment), SLvar (stride length variation), tc (contact time)] were significantly associated with higher proportions of all injuries. Conclusion: Biomechanical pole vault patterns during the competition day were associated with a higher proportion of history of all injuries. Although the injury data collection was retrospective leading to recall bias risk, and do not allow determining cause-consequence relationships regarding biomechanical patterns and injury occurrence, this present study is the first to analyze potential association between the biomechanical pole vault patterns and injury occurrence, which is of great help to provide hypotheses/ideas to design future studies and to move forward into prevention measures.

14.
J Strength Cond Res ; 33(10): 2768-2777, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28796126

RESUMEN

Isacco, L, Ennequin, G, Cassirame, J, and Tordi, N. Physiological pattern changes in response to a simulated competition in elite women's artistic gymnasts. J Strength Cond Res 33(10): 2768-2777, 2019-The outstanding progress in women's artistic gymnastics in recent decades has led to increased technical and physiological demands. The aim of this study was to investigate (a) the physiological demands of elite French gymnasts and (b) the impact of a competitive routine on physiological pattern changes. Fourteen French elite female gymnasts performed anthropometric measurements, physical fitness tests, and a simulated 4-event competition. Heart rate (HR) was continuously recorded throughout the duration of the simulated competition. Blood lactate concentrations were assessed at rest, before the beginning and at 2, 4, and 10 minutes after completion of the routine on each apparatus. Isometric handgrip strength and anaerobic endurance and power were assessed during the simulated competition. The highest values of HR and blood lactate concentrations were reached during the floor and uneven bar exercises. Blood lactate concentrations and HR kinetics were apparatus dependent and values remained significantly increased at 10 minutes of recovery compared with resting data. Anaerobic endurance and power decreased significantly as the competition progressed (p < 0.001). The present results show specifically cardiorespiratory and anaerobic apparatus-dependent responses throughout a simulated competition. Recovery approaches seem relevant to prevent and minimize fatigue and optimize performance in these athletes.


Asunto(s)
Conducta Competitiva/fisiología , Gimnasia/fisiología , Adolescente , Umbral Anaerobio , Femenino , Fuerza de la Mano , Frecuencia Cardíaca , Humanos , Ácido Láctico/sangre , Aptitud Física
15.
J Biomech ; 72: 99-105, 2018 04 27.
Artículo en Inglés | MEDLINE | ID: mdl-29559241

RESUMEN

This study was designed to examine the influence of standing position (vs. seated) during uphill cycling on both mechanical cost (MC) and energy cost (EC) in elite cyclists. For the study, thirteen elite cyclists (VO2max: 71.4 ±â€¯8.0 ml·min-1·kg-1) performed, in a randomised order, three sets of exercises. Each set comprised 2 min of exercise, alternating every 30 s between seated and standing postures, using different slopes and intensity levels on a motorised treadmill. MC was calculated from the measurement of power output and speed, whereas EC was calculated from the measurement of oxygen consumption and speed. MC was significantly higher (+4.3%, p < 0.001) in standing position compared to seated position when all slopes and intensities were considered. However, EC was not significantly affected by the change in position. The standing position also induced a significant increase in rolling resistance power (p < 0.001), rolling resistance coefficient (p < 0.001) and lateral sways (p < 0.001). The significant increase in MC observed in standing position was due to a higher rolling resistance induced by bicycle sways and a shift forward of the centre of mass compared to seated position. This result should lead bicycle tire manufacturers to reduce the increase in rolling resistance between the two positions. Considering the relationship observed between the MC and bicycle sways, cyclists would be well advised to decrease the bicycle sways in order to reduce the MC of locomotion.


Asunto(s)
Ciclismo/fisiología , Metabolismo Energético , Sedestación , Posición de Pie , Adolescente , Adulto , Prueba de Esfuerzo , Humanos , Locomoción/fisiología , Consumo de Oxígeno , Adulto Joven
16.
Int J Sports Physiol Perform ; 13(6): 717-723, 2018 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-29035596

RESUMEN

BACKGROUND: Approach speed is a major determinant of pole-vault performance. Athletic jump events such as long jump, triple jump, and pole vault can utilize an elevated track for the runway. Feedback from athletes indicates a benefit of using an elevated track on their results. However, there is no evidence that elevated tracks increase athletes' performance. PURPOSE: To investigate the potential advantage of using an elevated track during elite pole-vault competitions on run-up speed parameters. METHODS: Performance and run-up criteria (speed, stride rate, contact, and aerial time) were measured from 20 high-level male pole-vaulters during official competitions on either a regular or an elevated track. Parameters comparisons were made between both conditions, and run-up parameters were confronted to speed modification on the elevated track. RESULTS: Statistical analyses indicated that for the elevated track, there was a small improvement in final speed (1.1%), stride rate (1.1%), and takeoff distance (3.1%) and a small reduction in aerial time (-1.9%). The study highlighted different individual responses depending on athletes' capabilities. The authors noted that speed improvement was largely correlated with stride-rate improvement (r = .61) and contact-time reduction (r = -.51) for slower athletes. CONCLUSIONS: Elevated tracks can increase final approach speed in pole vault and positively influence performance. Interindividual responses were observed in these findings.


Asunto(s)
Rendimiento Atlético/fisiología , Conducta Competitiva/fisiología , Atletismo/fisiología , Aceleración , Adolescente , Fenómenos Biomecánicos , Humanos , Masculino , Movimiento , Carrera/fisiología , Adulto Joven
17.
Australas Phys Eng Sci Med ; 40(4): 831-839, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29058222

RESUMEN

Heart rate variability (HRV) analysis is widely used to investigate autonomous cardiac drive. This method requires periodogram measurement, which can be obtained by an electrocardiogram (ECG) or from a heart rate monitor (HRM), e.g. the Garmin 920 XT device. The purpose of this investigation was to assess the accuracy of RR time series measurements from a Garmin 920 XT HRM as compared to a standard ECG, and to verify whether the measurements thus obtained are suitable for HRV analysis. RR time series were collected simultaneously with an ECG (Powerlab system, AD Instruments, Castell Hill, Australia) and a Garmin XT 920 in 11 healthy subjects during three conditions, namely in the supine position, the standing position and during moderate exercise. In a first step, we compared RR time series obtained with both tools using the Bland and Altman method to obtain the limits of agreement in all three conditions. In a second step, we compared the results of HRV analysis between the ECG RR time series and Garmin 920 XT series. Results show that the accuracy of this system is in accordance with the literature in terms of the limits of agreement. In the supine position, bias was 0.01, - 2.24, + 2.26 ms; in the standing position, - 0.01, - 3.12, + 3.11 ms respectively, and during exercise, - 0.01, - 4.43 and + 4.40 ms. Regarding HRV analysis, we did not find any difference for HRV analysis in the supine position, but the standing and exercise conditions both showed small modifications.


Asunto(s)
Frecuencia Cardíaca/fisiología , Monitoreo Fisiológico/instrumentación , Adulto , Electrocardiografía , Ejercicio Físico , Femenino , Humanos , Masculino , Postura , Posición Supina
18.
J Sports Sci Med ; 15(4): 670-677, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27928213

RESUMEN

The aim of this study was to evaluate the reproducibility and validity of the "Footeval" test, which evaluates football players' aerobic level in conditions close to those of football practice (intermittent, including technical skills). Twenty-four highly trained subjects from an elite football academy (17.8 ± 1.4 years, 5 training sessions per week) performed two Footeval sessions in a period of 7 days. Physiological variables measured during these sessions (VO2max 58.1 ± 5.6 and 58.7 ± 6.2 ml·min-1·kg-1; RER 1.18 ± 0.06 and 1.19 ± 0.05; LaMax 11.0 ±1.4 and 10.8 ±1.1 µmol·L-1; HRmax 194 ± 6 and 190 ± 7 b·min-1; Final step 10.71 ± 1.2 and 10.83 ± 1.13 and the RPE = 10) highlighted maximal intensity and confirmed that players reached physiological exhaustion. Comparison of values measured in both sessions showed large to very large correlations (Final level; 0.92, VO2max; 0.79, HRmax; 0.88, LaMax; 0.87) and high ICC (Final level; 0.93, VO2max; 0.87, HRmax; 0.90, LaMax; 0.85) except for RER (r = 0.22, ICC = 0.21). In addition, all subjects performed a time limit (Tlm) exercise with intensity set at maximal aerobic specific speed + 1 km·h-1, in order to check the maximal value obtained during the Footeval test. Statistical analysis comparing VO2max, HRmax and RER from the Footeval and Tlm exercise proved that values from Footeval could be considered as maximal values (r for VO2max; 0.82, HRmax; 0.77 and ICC for VO2max; 0.92, HRmax; 0.91). This study showed that Footeval is a reproducible test that allows maximal aerobic specific speed to be obtained at physiological exhaustion. Moreover, we can also affirm that this test meets the physiological exhaustion criteria as defined in the literature (RER ≥ 1, 1; LaMax ≥ 8 µmol·L-1; HR = HRmax; no increase of VO2 despite the increase of speed; RPE =10).

19.
Rev. bras. cineantropom. desempenho hum ; 17(4): 409-417, July-Aug. 2015. tab, graf
Artículo en Inglés | LILACS | ID: lil-767178

RESUMEN

Abstract The aim of this study was to assess the accuracy of the Suunto Memory Belt (SMB) heart rate (HR) recorder compared with that of a standard electrocardiogram system (ECG) and compared the heart rate variability (HRV) analyses conducted with each dataset. Heart rate was simultaneously recorded using ECG and SMB in fifteen participants [mean (SD) age 27.3 (13.9) years, height 177.4 (10.2) cm and body mass 66.8 (15.3) kg] during an orthostatic tilt test. The two datasets were analysed to compare the number and type of R-R interval artefacts and indices from HRV (RMSSD, pNN50, HF, LF, SD1, and SD2). For artefact detection, 16,742 R-R intervals were analysed during all recordings. Only 18 artefacts, 9 type 1 (long R-R interval) and 9 type 2 (short R-R interval), were identified with the SMB. Bland-Altman analysis indicated excellent accuracy for the SMB, with limits of agreement of -2.00 and +1.94 ms. Further, the reference and SMB systems were strongly correlated. The similarity between each device indicated that the SMB could reliably record R-R intervals.


Resumo Este estudo foi realizado com o objetivo de avaliar a precisão das medidas de Frequencia cardíaca (FC) e da variabilidade da FC (VFC) obtidas através de um cardiofrequencímetro Suunto Memory Belt, em comparação com um sistema de eletrocardiograma (ECG) de referência. Quinze participantes [média (desvio padrão), idade de 27,3 (13,9) anos, estatura de 177,4 (10,2) cm e massa corporal de 66,8 (15,3) kg] foram equipados para o registro simultâneo da FC através do ECG de referência e do cardiofrequencímetro Suunto Memory Belt durante um teste de inclinação ortostático. Os dados obtidos pelos dois sistemas foram analisados para comparar o número e tipo de artefatos dos interavalos R-R e também comparar diversos indices de VFC (RMSSD, pNN50, HF, LF, SD1 e SD2). Para todos os participantes, foram analisados 16.742 intervalos R-R e comparados entre os dois sistemas. Somente 18 artefatos foram encontrados para o Suunto Memory Belt em relação o ECG de referência: 9 foram do tipo 1 (intervalos RR longos) e 9 do tipo 2 (intervalos RR curtos). A análise de Bland-Altman mostrou excelente precisão do sistema Suunto Memory Belt com limites de concordância entre -2.00 e +1.94 ms. O sistema Suunto Memory Belt também mostrou uma forte correlação com o sistema ECG de referência. De acordo com os testes realizados, e a similaridade com o ECG de refêrencia conclui-se que o Suunto Memory Belt é capaz de registrar de forma precisa os intervalos R-R.

20.
Eur J Sport Sci ; 15(7): 615-22, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25228474

RESUMEN

The capacity to predict the heart rate (HR) and speed at the first (VT1) and second (VT2) ventilatory thresholds was evaluated during an incremental ski-mountaineering test using heart rate variability (HRV). Nine skiers performed a field test to exhaustion on an alpine skiing track. VT1 and VT2 were individually determined by visual analysis from gas exchanges (VT1V and VT2V) and time-varying spectral HRV analysis (VT1fH, VT2fH and VT2H). VT1 could not be determined with the HRV methods used. On the contrary, the VT2 was determined in all skiers. No significant difference between HR and speed at VT2H and VT2V was observed (174.3 ± 5.6 vs. 174.3 ± 5.3 bpm, and 6.3 ± 0.9 and 6.3 ± 0.9 km h(-1), respectively). Strong correlations were obtained for HR (r = 0.91) and speed (r = 0.92) at VT2H and VT2V with small limits of agreement (±3.6 bpm for HR). Our results indicated that HRV enables determination of HR and speed at VT2 during a specific ski-mountaineering incremental test. These findings provide practical applications for skiers in order to evaluate and control specific training loads, at least when referring to VT2.


Asunto(s)
Altitud , Umbral Anaerobio , Rendimiento Atlético , Frecuencia Cardíaca , Resistencia Física/fisiología , Esquí/fisiología , Adulto , Prueba de Esfuerzo , Fatiga , Femenino , Humanos , Masculino , Montañismo , Consumo de Oxígeno
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA