RESUMEN
The aim of this study was to evaluate two cryoprotectants, dimethylformamide (DMF) and methylformamide (MF) in two concentrations (5 and 7 %) in vitro in donkey semen using a rapid freezing technique and the effect on pregnancy rates in mares. Twenty-four ejaculates from 8 jacks (n = 8; r = 3) were divided into 4 extenders: BotuSemen Gold with 5 % or 7 % MF and 5 % or 7 % DMF, all containing 11 % lactose, 20 % egg-yolk and 0.5 % Equex. Post-thaw evaluations included: sperm motility, membrane function and acrosome status. A linear mixed effect model was used to test the effect of different freezing media on semen parameters. No differences were observed between the 4 freezing media used, for any of the seminal parameters (P > 0.05). However, samples with 5 % DMF showed the highest percentages of sperm with acrosomes and functional membranes (DMF: 5 %: 53.67 ± 22.01; 7 %: 33.92 ± 23.4; MF: 5 %: 44.5 ± 20.46; 7 %: 38.75 ± 27.4) (Data: mean ± SD; P > 0.05). Hence, thirty mares were inseminated: 15 with 5 % DMF and 15 with 7 % DMF. The pregnancy rate was 46 % (7/15) and 0 % (0/15) using the extender with 5 % or 7 % DMF, respectively (P = 0.003). To conclude, the use of 5 % or 7 % of MF or DMF did not affect the in vitro parameters. Despite the lack of differences in vitro with the two DMF concentrations, in vivo results only showed pregnancies when using 5 % DMF. Thus, the results of this study demonstrate the importance of accompanying in vitro semen evaluations with studies that evaluate post-insemination pregnancy rates.
Asunto(s)
Criopreservación , Crioprotectores , Equidae , Preservación de Semen , Animales , Equidae/fisiología , Preservación de Semen/veterinaria , Preservación de Semen/métodos , Crioprotectores/farmacología , Femenino , Masculino , Criopreservación/métodos , Criopreservación/veterinaria , Embarazo , Dimetilformamida/farmacología , Inseminación Artificial/veterinaria , Semen/efectos de los fármacos , Semen/química , Motilidad Espermática/efectos de los fármacos , FormamidasRESUMEN
The aim of this study was to evaluate alpaca pregnancy outcomes and birth rates of females inseminated with frozen semen using two commercial extenders. A total of 18 ejaculates from 8 adult alpaca males were obtained with artificial vagina, and macroscopic and microscopic semen characteristics were assessed. Afterwards, samples were divided into two aliquots, diluted with Biladyl® B or AndroMed®, and cooled for 2 h at 5°C. At that moment, sperm motility was evaluated, and samples were frozen through a gradual descent of temperature using a liquid nitrogen tank. To analyse frozen sperm quality, samples were thawed at 38°C for 30 s. Even though a significant decrease in sperm motility and viability was detected when thawed (p < .05), no superiority was found between the two commercial extenders (Biladyl® B vs. AndroMed®). A total of 36 alpaca females were artificially inseminated (AI) between 30 and 34 h post-injection of a GnRH analogue, administered when a growing dominant follicle was detected through transrectal palpation and ultrasonography. Obtained pregnancy rates were similar between Biladyl® B (33.3%, 6/18) and AndroMed® (22.2%, 4/18). No significant differences were detected in birth rates between the two tested extenders, obtaining 4 and 3 births for Biladyl® and AndroMed®, respectively. In conclusion, alpaca pregnancies and alive offspring can be obtained through AI with frozen semen at similar efficiency rates using commercial diluents, Biladyl® B or AndroMed®.
Asunto(s)
Camélidos del Nuevo Mundo , Preservación de Semen , Embarazo , Femenino , Masculino , Animales , Preservación de Semen/veterinaria , Semen , Tasa de Natalidad , Crioprotectores , Criopreservación/veterinaria , Motilidad Espermática , Espermatozoides , Inseminación Artificial/veterinariaRESUMEN
In the last years, there has been an increasing interest in llamas, not only as part of a productive system, but mostly as companion animals. Most reports regarding clinical biochemistry and haematology include few llamas and details about their health status are not available. The present study aims to provide haematological and biochemical parameters for llamas of known health status. Twenty-three non-pregnant females and seven males that live in Buenos Aires, Argentina (34°36'S, 58°22'W, at sea level) were studied. Llamas were clinically healthy, in good nutritional status. Animals were kept at grass and were fed hay bale or pellets and water ad libitum. Blood samples were collected by jugular venipuncture in spring. Packed cell volume, leucocyte count, differential white cell count, platelets count, urea, creatinine, total proteins, albumin, alkaline phosphatase, aspartate aminotransferase, alanine aminotransferase, glucose, calcium and phosphate were assessed. No significant differences were observed between males and females, except for platelet count and calcium, which was greater in males (PË0.01). Values obtained for the different parameters were similar to those previously reported, except for monocytes, alkaline phosphatase, glucose and calcium, that were lower and lymphocytes and platelets count, that were higher in this study. In conclusion, different ambient and methodological conditions might affect some parameters. The parameters hereby presented are representative of llama's population living at sea level in South America.
Asunto(s)
Camélidos del Nuevo Mundo , Hematología , Masculino , Femenino , Animales , Calcio , Fosfatasa Alcalina , Glucosa , Estado de Salud , Valores de Referencia , Análisis Químico de la Sangre/veterinariaRESUMEN
Seminal plasma (SP) of South American Camelids could interfere with the interaction of spermatozoa with the extenders; therefore it becomes necessary to improve semen management using enzymatic treatment. Our objective was to compare two cooling protocols for llama semen. Twelve ejaculates were incubated in 0.1% collagenase and then were divided into two aliquots. One was extended in lactose and egg yolk (LEY) (Protocol A: collagenase and SP present). The other aliquot was centrifuged, and the pellet was resuspended in LEY (Protocol B: collagenase and SP absent). Both samples were maintained at 5°C during 24 hr. Routine and DNA evaluations were carried out in raw and cooled semen. Both cooling protocols maintained sperm viability, membrane function and DNA fragmentation, with Protocol A showing a significantly lowered total and progressive motility (p < .05) and Protocol B showing a significant increase in chromatin decondensation (p < .05). Protocol A avoids centrifugation, reducing processing times and making application in the field simpler. However, as neither protocol showed a significant superiority over the other, studies should be carried out in vivo to evaluate the effect on pregnancy rates of the presence of collagenase and SP in semen samples prior to either cooling or freeze-thawing.
Asunto(s)
Colagenasas , Criopreservación/métodos , Preservación de Semen/métodos , Semen , Animales , Camélidos del Nuevo Mundo , Masculino , Análisis de Semen , Motilidad Espermática , EspermatozoidesRESUMEN
The objective of this study was to compare the efficiency of different sperm selection methods applied to the same llama ejaculate. Four treatments were compared: two variants of the swim up technique (with and without seminal plasma), and two different colloids, Androcoll-E-Large and Percoll(®). Using electroejaculation, 21 semen samples were obtained from 7 llama males (n=7, r=3). The ejaculates were incubated in a solution of 0.1% collagenase, to decrease thread formation, and then split into 4 aliquots: one aliquot was layered over a column of Androcoll-E-Large (SLC) and the second over a column of Percoll (45%). The third aliquot was deposited in a tube with culture medium and was incubated at a 45° angle for 30min at 37°C (SU1). The last aliquot was centrifuged to separate the spermatozoa and seminal plasma. The sperm pellet obtained was resuspended, and transferred to a tube with culture medium which was incubated at an angle of 45° for 30min at 37°C (SU2). Both aliquots SLC and P showed higher proportions of progressive motility and plasma membrane functionality (p≤0.05) than raw semen. There were no significant differences (p>0.05) in sperm viability and in normal spermatozoa between raw semen and treatments. Nevertheless, only SLC did not have a significant increase of bent tails. In conclusion SLC centrifugation would be the method of choice for selecting llama spermatozoa.
Asunto(s)
Camélidos del Nuevo Mundo/fisiología , Separación Celular/métodos , Animales , Masculino , Análisis de Semen/veterinaria , Preservación de Semen/veterinaria , Motilidad Espermática/fisiología , Espermatozoides/fisiologíaRESUMEN
The aim of this study was to determine the effect of two equilibration temperatures (5 °C and room temperature) and two cryoprotectants (glycerol and dimethylformamide, both at 7%) on llama sperm cryopreservation. Llama ejaculates were divided into four aliquots. A lactose-EDTA-egg yolk (LEEY) extender with either 7% glycerol (LEEY-G) or 7% dimethylformamide (LEEY-DMF) was added to two of the aliquots, which were equilibrated for 20 min at room temperature and subsequently frozen. The other two aliquots were extended in LEEY, cooled to 5 °C, then LEEY-G or LEEY-DMF was added, equilibrated for 20 min at 5 °C and frozen. No significant differences (P > 0.05) were observed in membrane function and chromatin condensation between any of the freeze-thawing protocols. Post-thaw motility was greater (P < 0.05) in LEEY-DMF than LEEY-G. DNA fragmentation was not different between raw and frozen semen with LEEY-DMF but was high in all samples with glycerol. Our results indicate that 7% glycerol would be detrimental for llama spermatozoa, but further studies are needed to evaluate effectiveness if used at lower concentrations. Dimethylformamide preserved motility and DNA integrity of frozen-thawed llama spermatozoa and could be used to replace glycerol at the concentrations used in this study.
Asunto(s)
Camélidos del Nuevo Mundo/metabolismo , Criopreservación/métodos , Crioprotectores/uso terapéutico , Espermatozoides/metabolismo , Animales , Frío , MasculinoRESUMEN
The integrity of sperm chromatin is now viewed as an important factor in male fertility and in early embryonic development. The objectives of this study were: (1) adapt the simple and inexpensive sperm chromatin dispersion (SCD) test to evaluate DNA fragmentation in llama sperm and establish the halo patterns observed in this species, (2) determine an effective and reliable positive control for this technique and (3) evaluate correlation between the SCD test and the toluidine blue (TB) stain. To adapt the SCD test, three different mercaptoethanol (ME) concentrations were assayed (2.5%, 5% and 10% ME). To determine an effective positive control, three treatments (incubation at 100 °C for 30 min, incubation with 0.3 M NaOH for 30 min at room temperature and exposure to UV light for 2h) were assayed. The concentration selected to use in the SCD test was 5% ME, because it produced the largest halo while still conserving the structure of the core. Four DNA dispersion patterns were clearly observed: (I) nuclei with large DNA dispersion halos; (II) nuclei with medium halos; (III) nuclei with very small halos and (IV) nuclei with no halo. All treatments used as positive controls were effective in producing DNA fragmentation. A high correlation (r=0.84, P=0.03) was observed between spermatozoa without halos and TB positive cells. To conclude, SCD patterns in llama sperm have been established as well as a repeatable positive control for the assay. The SCD test and TB stain are simple and inexpensive techniques that can be used to evaluate DNA damage in llama sperm.
Asunto(s)
Camélidos del Nuevo Mundo/genética , Cromatina/genética , Fragmentación del ADN , Espermatozoides/fisiología , Animales , Cromatina/química , Masculino , Mercaptoetanol/química , Espermatozoides/química , Cloruro de Tolonio/químicaRESUMEN
The effect cryopreservation has on sperm chromatin condensation has been studied in many species but not in South American camelids. The objectives of this study were to evaluate with toluidine blue (TB) the effects of cooling and of adding collagenase on llama sperm DNA condensation. The optimum incubation time (30 s, 1.5 and 3 min) with a reducing agent (dithiothreitol) was also determined. When comparing cooled samples with the raw ejaculate, a significant increase in sperm showing a high degree of decondensation (TB positive) was observed (P = 0.005). A positive correlation was observed, both in raw and cooled semen, between sperm head morphological abnormalities observed in TB-stained cells and TB-positive sperm (highly decondensed DNA), but not with TB-intermediate spermatozoa (moderately decondensed DNA). No significant differences (P > 0.05) were observed in samples incubated with or without 0.1% collagenase. In cooled semen, but not in raw, a significant increase (P = 0.000) in reacted sperm (TB positive) was observed using 3-min incubation with 1% dithiothreitol (DTT). To conclude, cooling would seem to produce an increase in llama sperm chromatin decondensation. Also, 0.1% collagenase in H-TALP-BSA could be added to raw semen to aid its manipulation as it would not seem to increase DNA decondensation.
Asunto(s)
Colagenasas/administración & dosificación , Criopreservación , ADN/química , Preservación de Semen , Espermatozoides/ultraestructura , Cloruro de Tolonio/química , Animales , Camélidos del Nuevo Mundo , Cromatina/metabolismo , Masculino , Espermatozoides/metabolismoRESUMEN
Llama production in Argentina has increased, as the international interest in breeding this type of animals has grown in the last years. Considering the great polymorphism that llama spermatozoa present at evaluation using light microscopy, the aim of this study was to objectively evaluate llama sperm head morphometry using digital morphometric analysis. Five ejaculates from each of eight males were obtained to evaluate morphometric parameters of 8000 sperm heads stained with Tinción 15(®). The following average results were obtained for each parameter: size parameters: area 20.09 µm(2), length 6.60 µm, width 4.14 µm, equivalent circle diameter 5.06 µm, curve length 5.79 µm and curve width 3.48 µm; boundary parameters: perimeter 18.54 µm and convex perimeter 17.34 µm; and shape parameters: roundness 1.28 and elongation 1.59. Morphometric parameters of sperm head were compared between ejaculates of the same male and between males. Significant differences between ejaculates of the same male were found for all parameters evaluated (P < 0.01). Significant differences between males were found for all morphometric parameters (P < 0.01) except for curve length, curve width and perimeter. The differences detected would indicate that there is not a single morphometric pattern for Lama glama sperm head, because parameter values cannot be standardised.