Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Intervalo de año de publicación
1.
Braz J Cardiovasc Surg ; 32(5): 401-407, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29211221

RESUMEN

OBJECTIVE: To evaluate the safety and feasibility of a novel stent-graft for thoracic endovascular aortic repair (TEVAR) in a canine model, 9 adult hybrid dogs were used for the experiment. METHODS: All animals were implanted with a novel thoracic aortic stent-graft via femoral artery. Blood sample was collected at pre-operation and 1, 2, 4, 8 and 12 weeks after implantation for hematological examination. Moreover, tissues from randomly selected 4 dogs were subjected to histopathological analysis with the optical microscope after stent-grafts were implanted for 3, 6, 9, and 12 months respectively. The experimental period lasted for more than 2 years. RESULTS: A total of 9 stent-grafts were successfully implanted in the canine thoracic aortas and no migration or deformation occurred. Related indicators of blood routine, inflammatory factors, and immunology changes were not significantly (P>0.05), except the white blood cell (WBC) counts in the first week. Moreover, abnormal morphology was not found in all thoracic aortas via histopathological examination. Additionally, all stent-grafts were patent and did not migrate, and there was no thrombus in the lumens of stent-grafts. CONCLUSION: The novel thoracic aortic stent-graft made in China was safe and feasible for thoracic endovascular aortic repair in a canine model.


Asunto(s)
Aorta Torácica/cirugía , Implantación de Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Animales , Perros , Estudios de Factibilidad , Ensayo de Materiales , Modelos Animales , Diseño de Prótesis , Factores de Tiempo
2.
Rev. bras. cir. cardiovasc ; Rev. bras. cir. cardiovasc;32(5): 401-407, Sept.-Oct. 2017. tab, graf
Artículo en Inglés | LILACS | ID: biblio-897950

RESUMEN

Abstract Objective: To evaluate the safety and feasibility of a novel stent-graft for thoracic endovascular aortic repair (TEVAR) in a canine model, 9 adult hybrid dogs were used for the experiment. Methods: All animals were implanted with a novel thoracic aortic stent-graft via femoral artery. Blood sample was collected at pre-operation and 1, 2, 4, 8 and 12 weeks after implantation for hematological examination. Moreover, tissues from randomly selected 4 dogs were subjected to histopathological analysis with the optical microscope after stent-grafts were implanted for 3, 6, 9, and 12 months respectively. The experimental period lasted for more than 2 years. Results: A total of 9 stent-grafts were successfully implanted in the canine thoracic aortas and no migration or deformation occurred. Related indicators of blood routine, inflammatory factors, and immunology changes were not significantly (P>0.05), except the white blood cell (WBC) counts in the first week. Moreover, abnormal morphology was not found in all thoracic aortas via histopathological examination. Additionally, all stent-grafts were patent and did not migrate, and there was no thrombus in the lumens of stent-grafts. Conclusion: The novel thoracic aortic stent-graft made in China was safe and feasible for thoracic endovascular aortic repair in a canine model.


Asunto(s)
Animales , Perros , Aorta Torácica/cirugía , Stents , Implantación de Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Diseño de Prótesis , Factores de Tiempo , Ensayo de Materiales , Estudios de Factibilidad , Modelos Animales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA