Water Res ; 134: 92-100, 2018 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-29407655

RESUMEN

Wastewater treatment plants have widely been described as a significant source of odour nuisance, which has led to an increase of neighbourhood complaints. Therefore, to mitigate the negative impact of odours, the detection and analysis of these emissions are required. This paper presents a measurement system based on an electronic nose for quantitative and qualitative odour analysis of samples collected from six different stages on a wastewater plant. Hence, two features vectors were performed in order to represent quantitative trends of the gaseous mixture sampled on the facility. In addition, odour fingerprints and a PCA were computed to discriminate odours from its sources and to detect relationships among the samples. This approach also comprises a dynamic dilution olfactometer. A PLS regression model was performed to predict the odour concentration by the electronic nose in term of odour units per cubic meter. The results show that the developed electronic nose is a promising and feasible instrument to characterize odours from wastewater plants.


Asunto(s)
Contaminantes Atmosféricos/análisis , Nariz Electrónica , Odorantes/análisis , Eliminación de Residuos Líquidos , Aguas Residuales , Análisis de los Mínimos Cuadrados , Análisis de Regresión