Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Data Brief ; 33: 106550, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33294534

RESUMEN

This article presents a five-part dataset for human gait analysis in a healthy older adult population (37 women and seven men; age 69.98 ± 8.57 years, body mass index 27.71 ± 4.57). Part 1 compromises demographic data for the 44 participants, along with the results of the Short Physical Performance Battery (SPPB) motor function test and the Mini-Mental State Examination (MMSE). We used the MMSE to ensure the participants could understand the experimental protocol instructions. Part 2 presents the anthropometric measurements of the participants. Part 3 shows the results for each item of the Gait component of the Performance Oriented Mobility Assessment (POMA-G). Part 4 contains five files per participant, storing motion-capture data for the lower limb in the Coordinate 3D (C3D) format. These files were generated using a Vicon motion analysis system, consisting of 24 reflective markers and seven cameras (Vantage V5) sampled at 100 Hz. Part 5 contains 26 gait parameters for each C3D file obtained using Nexus 2.9.3. The dataset is available in a Mendeley repository (Reserved DOI: 10.17632/xgw6bg3g8h.1).

2.
HardwareX ; 8: e00126, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35498248

RESUMEN

This paper proposes a low-cost portable electronic system for estimating step width during the human gait cycle. This device, intended to support the Walking Stance item of the fall risk assessment test Performance Oriented Mobility Assessment (POMA), contains three electronic boards, comprising two sensing nodes and a concentrator. Each sensing node contains a force sensitive resistor (FSR) and time-of-flight camera (TOF). Each FSR is placed inside the subject's shoe, while each TOF camera is located at the back of their foot. The FSR detects contact between heel and ground, and the TOF measures the distance to a barrier located on the right side of the walking path. Step width is calculated as the difference between the TOF measurements. After the walk is complete, the information obtained by the FSRs and TOFs is sent via a 433 MHz wireless communication to the concentrator board, which is connected to the USB port of a personal computer (PC). The proposed step width measurement system was validated with an infrared based motion capture (Vicon Corp.), giving an error equal to 11.4%  ±  5.5%.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA