Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Intervalo de año de publicación
1.
Pathogens ; 10(11)2021 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-34832654

RESUMEN

(1) Background: We reviewed the logistics of the implementation of pathogen reduction (PR) using the INTERCEPT Blood System™ for platelets and the experience with routine use and clinical outcomes in the patient population at the Sírio-Libanês Hospital of São Paulo, Brazil. (2) Methods: Platelet concentrate (PC), including pathogen reduced (PR-PC) production, inventory management, discard rates, blood utilization, and clinical outcomes were analyzed over the 40 months before and after PR implementation. Age distribution and wastage rates were compared over the 10 months before and after approval for PR-PC to be stored for up to seven days. (3) Results: A 100% PR-PC inventory was achieved by increasing double apheresis collections and production of double doses using pools of two single apheresis units. Discard rates decreased from 6% to 3% after PR implementation and further decreased to 1.2% after seven-day storage extension for PR-PCs. The blood utilization remained stable, with no increase in component utilization. A significant decrease in adverse transfusion events was observed after the PR implementation. (4) Conclusion: Our experience demonstrates the feasibility for Brazilian blood centers to achieve a 100% PR-PC inventory. All patients at our hospital received PR-PC and showed no increase in blood component utilization and decreased rates of adverse transfusion reactions.

2.
Transfusion ; 61(12): 3455-3467, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34674284

RESUMEN

BACKGROUND: COVID-19 high-titer CCP selection is a concern, because neutralizing antibody (nAb) testing requires sophisticated labs and methods. Surrogate tests are an alternative for measuring nAb levels in plasma bags, including those that are pathogen-reduced. STUDY DESIGN/METHODS: We studied a panel consisting of 191 samples from convalescent donors tested by nAb (CPE-VNT), obtained from 180 CCP donations (collection: March 20-January 21) and 11 negative controls, with a total of 80 and 111 serum and plasma samples (71 amotosalen/UV treated), with nAb titers ranging from negative to 10,240. Samples were blindly tested for several surrogates: one anti-RBD, two anti-spike, and four anti-nucleocapsid tests, either isolated or combined to improve their positive predictive values as predictors of the presence of high-titer nAbs, defined as those with titers ≥160. RESULTS: Except for combined and anti-IgA/M tests, all isolated surrogate tests showed excellent performance for nAb detection: sensitivity (98.3%-100%), specificity (85.7%-100%), PPV (98.9%-100%), NPV (81.3%-100%), and AUC (0.93-0.96), with a variable decrease in sensitivity and considerably lower specificity when using FDA authorization and concomitant nAb titers ≥160. All surrogates had AUCs that were statistically different from CPE-VNT if nAb≥160, including when using combined, orthogonal approaches. CONCLUSIONS: Surrogate tests (isolated or in combination) have an indirect good performance in detecting the presence of nAb, with lower sensitivity and specificity when high nAb titer samples are used, possibly accepting a considerable number of donors whose nAb titers are actually low, which should be evaluated by each laboratory responsible for CCP collection.


Asunto(s)
Anticuerpos Neutralizantes/uso terapéutico , Anticuerpos Antivirales/uso terapéutico , COVID-19/terapia , Donantes de Sangre , Humanos , Inmunización Pasiva , SARS-CoV-2 , Sueroterapia para COVID-19
3.
Transfusion ; 61(5): 1447-1460, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33604884

RESUMEN

INTRODUCTION: Little is known about the neutralizing (nAb) and binding antibody kinetics in COVID-19 convalescent plasma donors, especially during the first 100 days after disease onset. MATERIALS AND METHODS: A cohort of previously RT-PCR positive (detected by nasopharyngeal swab during the acute phase), male convalescent patients, all with mild symptoms, were enrolled in serial blood sample collection for a longitudinal nAb titers and anti-nucleocapsid (NP) antibodies (IgM, IgG and IgA) evaluation. NAbs were detected by a cytopathic effect-based virus neutralization test (CPE-based VNT), carried out with SARS-CoV-2 (GenBank: MT350282). RESULTS: A total of 78 male volunteers provided 316 samples, spanning a total of 4820 days of study. Although only 25% of donors kept nAb titers ≥160 within 100 days after the onset of disease, there was >75% probability of sustaining nAb titers ≥160 in volunteers whose initial nAb titer was ≥1280, weight ≥ 90 kg or obese, according to their body mass index (BMI), as evidenced by Kaplan-Meier analysis and Cox hazard regression (all p < .02). There was no correlation between the ABO group, ABO antibody titers and persistent high nAb titers. High IgG anti-NP (S/CO ≥5.0) is a good surrogate for detecting nAb ≥ 160, defined by the ROC curve (sensitivity = 90.5%; CI95%: 84.5%-94.7%). CONCLUSION: Selection of CCP donors for multiple collections based on initial high nAb titers (≥1280) or BMI ≥ 30 kg/m2 provides a simple strategy to achieve higher quality in CCP programs. High IgG anti-NP levels can also be used as surrogate markers for high nAb screening.


Asunto(s)
Sistema del Grupo Sanguíneo ABO/sangre , Anticuerpos Neutralizantes/sangre , Anticuerpos Antivirales/sangre , Donantes de Sangre , Seguridad de la Sangre , Índice de Masa Corporal , COVID-19/sangre , Nucleocápside/sangre , SARS-CoV-2/metabolismo , Adolescente , Adulto , Femenino , Humanos , Cinética , Estudios Longitudinales , Masculino , Persona de Mediana Edad
5.
Radiol. bras ; Radiol. bras;44(2): 135-136, mar.-abr. 2011. ilus
Artículo en Portugués | LILACS | ID: lil-588201

RESUMEN

Diverticulite jejunal é doença rara que acomete principalmente os idosos. Os sintomas e sinais clínicos são inespecíficos, fato que dificulta e retarda o diagnóstico. A tomografia computadorizada é muito valiosa na definição do diagnóstico. Neste relato será apresentado um caso de diverticulose jejunal complicada com diverticulite aguda perfurada bloqueada, assim como uma discussão breve sobre diverticulite jejunal e suas complicações.


Jejunal diverticulitis is a rare disease that primarily affects the elderly. Clinical signs and symptoms are nonspecific, a fact that complicates and delays the diagnosis. Computed tomography is very valuable in defining the diagnosis. The present report describes a case of jejunal diverticulosis complicated with acute perforated obstructive diverticulitis, and presents a brief discussion on jejunal diverticulitis and its complications.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA