Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
BMC Womens Health ; 21(1): 195, 2021 05 11.
Artículo en Inglés | MEDLINE | ID: mdl-33975584

RESUMEN

PURPOSE: Transient postoperative urinary retention (POUR) is common after pelvic floor surgery. We aimed to determine the association between peri-operative variables and POUR and to determine the number of voids required for post-void residuals (PVRs) to normalize postoperatively. METHODS: We conducted a retrospective cohort study of 992 patients undergoing pelvic floor surgery at a tertiary referral centre from January 2015 to October 2017. Variables assessed included: age, BMI, ASA score, anaesthesia type, type of surgery, length of postoperative stay, surgeon, bladder protocol used, and number of PVRs required to "pass" the protocol. RESULTS: Significant risk factors for POUR included: placement of MUS during POP surgery, anterior repair and hysterectomy with concomitant sacrospinous vault suspension. A total of 25.1% were discharged requiring catheterization. Patients receiving a concomitant mid-urethral sling (MUS) were 2.2 (95% CI1.6-2.9) and 2.3 (95% CI 1.8-3.1) times more likely to have elevated PVR after their second TOV and third TOV (p < 0.0001), respectively, compared with those without concomitant MUS. Permitting a third TOV allowed an additional 10% of women to pass the voiding protocol before discharge. The median number of voids to pass protocol was 2. An ASA > 2 and placement of MUS were associated with increasing number of voids needed to pass protocol. CONCLUSIONS: While many women passed protocol by the second void, using the 3rd void as a cut point to determine success would result in fewer women requiring catheterization after discharge. Prior to pelvic floor surgery, women should be counselled regarding POUR probability to allow for management of postoperative expectations.


Asunto(s)
Prolapso de Órgano Pélvico , Cabestrillo Suburetral , Incontinencia Urinaria de Esfuerzo , Retención Urinaria , Femenino , Humanos , Prolapso de Órgano Pélvico/cirugía , Complicaciones Posoperatorias/epidemiología , Estudios Retrospectivos , Retención Urinaria/etiología
2.
BJOG ; 122(12): 1705-12, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25316484

RESUMEN

OBJECTIVE: To evaluate impact of body mass index (BMI) ≥30 on objective and subjective cure rates 12 months after midurethral sling surgery. DESIGN: Secondary analysis. SETTING: Three hospitals in Calgary, Canada, 2005-07. POPULATION: A total of 182 women enrolled in a randomised control trial of tension-free vaginal tape versus transobturator tape. METHODS: Women were classified as obese or nonobese from height and weight on day of surgery. Women underwent postoperative standardised pad tests, self-reporting of urinary incontinence, and quality of life scores. Categorical data compared with chi-square or Fisher's exact, continuous data compared with Mann-Whitney U test. MAIN OUTCOME MEASURES: Primary outcome was objective cure, defined as <1 g urine loss on postoperative 1-hour pad test. Secondary outcomes were subjective cure of incontinence (no stress incontinence in previous 7 days), presence of urinary urgency in previous 7 days, Urogenital Distress Inventory (UDI-6) scores, Incontinence Impact Questionnaire (IIQ-7) scores, and surgical complication rates. RESULTS: Objective cure differed, with 85.6% of nonobese women leaking <1 g on 1-hour pad test, versus 67.8% of obese women (P = 0.006, risk difference [RD] 17.8%, 95% confidence interval [95% CI] 4.2-31.4%). Subjective cure was 85.8% for nonobese women versus 70.7% for obese women (P = 0.016, RD 15.1%, 95% CI 1.9-28.4%). For both groups, improvement was seen for postoperative UDI-6 (median -33.3 [-44.4 to -22.2] and -27.2 [-44.4 to -16.7]) and IIQ-7 scores (median -26.2 [-45.2 to -14.3] and -23.8 [-42.9 to -14.3]). No differences existed in rates of operative complications between the two groups. CONCLUSION: Twelve months after midurethral sling surgery, obese women experience lower rates of cure than those who are nonobese.


Asunto(s)
Obesidad/fisiopatología , Satisfacción del Paciente/estadística & datos numéricos , Cabestrillo Suburetral , Incontinencia Urinaria de Esfuerzo/cirugía , Adulto , Canadá/epidemiología , Femenino , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Obesidad/complicaciones , Calidad de Vida , Encuestas y Cuestionarios , Factores de Tiempo , Resultado del Tratamiento , Incontinencia Urinaria de Esfuerzo/epidemiología , Incontinencia Urinaria de Esfuerzo/fisiopatología
3.
BJOG ; 121(5): 634-40, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24621073

RESUMEN

OBJECTIVE: To describe the initial placement of Elevate single-incision mesh kit device tips relative to the sacrospinous ligament, and to measure tip movement over a 6-month period from initial placement. DESIGN: Prospective cohort. SETTING: Tertiary care urogynaecology centre in Calgary, Canada. POPULATION: Women electing for surgical management of anterior vaginal wall prolapse. METHODS: Ten women underwent anterior prolapse repair using the Elevate single-incision mesh kit with a metallic fiducial marker attached to the tips of the surgical device. Women were imaged by magnetic resonance imaging (MRI) within 48 hours of surgery, and again 6 months later to investigate the position of the device tips and change ≥4 mm over the 6-month postoperative period. MAIN OUTCOME MEASURE(S): Position of self-fixating tips within 48 hours of surgery, and at six months post-operative. RESULTS: Anchor insertion was directly into the sacrospinous ligament in 10 of 20 insertion points (50%, 95% CI 27-73%). Movement was most often noted in the cranial-caudal direction: a change in location of ≥4 mm was observed for 8/20 anchors (40%, 95% CI 19-64%). Cranial-caudal movement was observed less frequently among sacrospinous anchors than among anchors inserted into other pelvic structures (1/10 versus 7/10, P = 0.020, difference in proportion -60%, 95% CI -94 to -26%). PFDI-20 scores improved statistically significantly by 6 months (P = 0.008, mean change -62.9%, 95% CI -105.1 to -20.7%), but PFIQ-7 scores did not change statistically significantly over the same time period (P = 0.523, mean change -12.4%, 95% CI -54.5 to 29.8%). CONCLUSIONS: The novel self-fixating anchoring tips of this single-incision mesh kit do not reliably anchor into the sacrospinous ligament. The tips have been shown to move with time, although not all cases of anchor movement were associated with recurrent prolapse.


Asunto(s)
Marcadores Fiduciales , Migración de Cuerpo Extraño/diagnóstico , Procedimientos Quirúrgicos Ginecológicos/instrumentación , Imagen por Resonancia Magnética , Mallas Quirúrgicas , Prolapso Uterino/cirugía , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Procedimientos Quirúrgicos Ginecológicos/métodos , Humanos , Ligamentos/cirugía , Persona de Mediana Edad , Músculo Esquelético/cirugía , Estudios Prospectivos
4.
Phys Rev Lett ; 86(4): 600-3, 2001 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-11177891

RESUMEN

The two-neutron halo nucleus (14)Be has been investigated in a kinematically complete measurement of the fragments ((12)Be and neutrons) produced in dissociation at 35 MeV/nucleon on C and Pb targets. Two-neutron removal cross sections, neutron angular distributions, and invariant mass spectra were measured, and the contributions from electromagnetic dissociation (EMD) were deduced. Comparison with three-body model calculations suggests that the halo wave function contains a large nu(2s(1/2))(2) admixture. The EMD invariant mass spectrum exhibited enhanced strength near threshold consistent with a nonresonant soft-dipole excitation.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA