Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
1.
Clin Pharmacokinet ; 63(8): 1167-1176, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39102092

RESUMEN

BACKGROUND AND OBJECTIVE: Renal replacement therapy (RRT) plays a critical role in antimicrobial removal, particularly for low-molecular-weight drugs with low plasma protein binding, low distribution volume and hydrophilicity. Medium cut-off (MCO) membranes represent a new generation in dialysis technology, enhancing diffusive modality efficacy and increasing the cut-off from 30 to 45 kDa, crucial for middle molecule removal. This monocentric randomized crossover pilot study aimed to evaluate the impact of continuous haemodialysis with MCO membrane (MCO-CVVHD) on the removal of piperacillin, tazobactam and meropenem compared with continuous veno-venous hemodiafiltration with standard high-flux membrane (HFM-CVVHDF). METHODS: Twenty patients were randomized to undergo MCO-CVVHD followed by HFM-CVVHDF or vice versa. Extraction ratio (ER), effluent clearance (Cleff) and treatment efficiency were assessed at various intervals. Antibiotic nadir plasma levels were measured for both treatment days. RESULTS: HFM-CVVHDF showed greater ER compared with MCO-CVVHD for meropenem (ß = - 8.90 (95% CI - 12.9 to - 4.87), p < 0.001) and tazobactam (ß = - 8.29 (95% CI - 13.5 to - 3.08), p = 0.002) and Cleff for each antibiotic (meropenem ß = - 10,206 (95% CI - 14,787 to - 5787), p = 0.001); tazobactam (ß = - 4551 (95% CI - 7781 to - 1322), p = 0.012); piperacillin (ß = - 3913 (95% CI - 6388 to - 1437), p = 0.002), even if the carryover effect influenced the Cleff for meropenem and tazobactam. No difference was observed in nadir plasma concentrations or efficiency for any antibiotic. Piperacillin (ß = - 38.1 (95% CI - 47.9 to - 28.3), p < 0.001) and tazobactam (ß = - 4.45 (95% CI - 6.17 to - 2.72), p < 0.001) showed lower nadir plasma concentrations the second day compared with the first day, regardless the filter type. CONCLUSION: MCO demonstrated comparable in vivo removal of piperacillin, tazobactam and meropenem to HFM.


Asunto(s)
Antibacterianos , Terapia de Reemplazo Renal Continuo , Estudios Cruzados , Meropenem , Diálisis Renal , Choque Séptico , Humanos , Antibacterianos/farmacocinética , Antibacterianos/uso terapéutico , Antibacterianos/sangre , Masculino , Femenino , Persona de Mediana Edad , Anciano , Choque Séptico/terapia , Choque Séptico/tratamiento farmacológico , Choque Séptico/sangre , Proyectos Piloto , Terapia de Reemplazo Renal Continuo/métodos , Diálisis Renal/métodos , Meropenem/uso terapéutico , Meropenem/administración & dosificación , Meropenem/farmacocinética , Tazobactam/uso terapéutico , Tazobactam/farmacocinética , Piperacilina/farmacocinética , Piperacilina/uso terapéutico , Piperacilina/administración & dosificación , Hemodiafiltración/métodos
2.
Blood Purif ; : 1-8, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39068927

RESUMEN

INTRODUCTION: Enkephalins, endogenous opioid peptides, are involved in the regulation of renal function. One derived molecule, proenkephalin A, also known as penKid, has been demonstrated to be a reliable biomarker for kidney function and its plasma concentration correlates with measured glomerular filtration rate. penKid is used for prediction and diagnosis of AKI and need of renal replacement therapy (RRT). penKid has also been used to predict the successful weaning from RRT in patients with AKI. Whether the concentration of penKid is affected or not by RRT is a controversial point and there are no studies describing the kinetics of the molecule in such conditions. The low molecular weight (4.5 kDa) would imply free removal by the glomerulus and the dialysis membranes. During RRT, this reduction could not be detected in clinical practice due to the complex kinetics involving either low dialytic clearance or increased production in response to impaired kidney function. The aim of this study was to determine the sieving coefficient and the diffusive clearance of the penKid molecule in conditions of in vitro continuous veno-venous hemofiltration (CVVH) and continuous veno-venous hemodialysis (CVVHD), respectively, and also the penKid removal ratio in conditions of in vitro hemoadsorption (HA) using a synthetic microporous resin. METHODS: Blood spiked with a lyophilized penKid peptide solved in 20 mm dipotassium phosphate and 6 mm disodium EDTA [pH 8] to reach target concentrations is used as testing solution. In each experiment, the blood batch was adjusted at a volume of 1,000 mL, maintained at 37°, and continuously stirred. Samples were collected from blood, ultrafiltrate, and spent dialysate at different times during the experiments. Sieving, clearance, and removal ratio were calculated. RESULTS: Significant removal of penKid was observed in CVVH (sieving 1.04 ± 0.27), in CVVHD (clearance 23.08 ± 0.89), and in HA (removal ratio 76.1 ± 1% after 120 min). CONCLUSION: penKid is effectively removed by extracorporeal therapies. In presence of anuria, penKid generation kinetics can be calculated based on extracorporeal removal and volume variation. In steady state conditions, declining values may be the result of an initial renal function recovery and may suggest discontinuation and successful liberation from RRT.

3.
J Clin Med ; 13(7)2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38610912

RESUMEN

Background: Patients with end-stage kidney disease (ESKD) have altered immunity. Patients on hemodialysis (HD) present a coexistence of immunodeficiency and activation of the immune system. We evaluated the immunophenotypic profile induced by the medium cut-off of Theranova filter during a single HD session in the same individual. Methods: This pilot observational study explored 11 patients (75 ± 8 years and 73% male). Blood samples were collected prior to (predialytic, PRE) and after 4 h (postdialytic, POST) standard HD session with a medium cut-off, polyarylethersulfone and polyvinylpyrrolidone blend, BPA-free membrane. We performed an immunophenotyping characterization by using flow cytometry. We evaluated eryptosis RBCs and HLA-DR expression on monocytes and Treg cells. Results: The percentages of eryptosis in lymphocytes (CD3+), lymphocyte T helper (CD3+ and CD4+) cells, and monocytes (CD45+ and CD14+) were similar pre- and post-HD. On the contrary, HLA-DR expression and Treg cell numbers significantly decreased after HD. Conclusions: Many studies have focused on the comparison between healthy volunteers and HD patients, but very few have focused on the changes that occur after an HD session in the same individual. With this pilot observational study, we have revealed an immunomodulation driven by HD treatment with Theranova filter. Our preliminary results can be considered to be a hypothesis, generating and stimulating further studies with better designs and larger populations.

4.
Blood Purif ; 53(8): 613-623, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38493768

RESUMEN

INTRODUCTION: Per- and polyfluoroalkyl substances (PFAS) are known water pollutants leading to potential public health consequences. High blood levels of PFAS have been associated with several pathological conditions including testicular and kidney cancer. Classic extracorporeal therapies have demonstrated limited efficiency, and new approaches should be explored. In this study, we studied the possible role of hemoadsorption to achieve a fast, safe, and effective removal of PFAS from blood in patients with high blood levels. METHODS: We developed an in vitro model of hemoadsorption to test the potential of PFAS removal by extracorporeal treatment. We recirculated a highly polluted batch of water (4 L) through a sorbent cartridge (Jafron Medical, Zhuhai, China) for 120 min at a flow of 150 mL/min. We collected samples at different time points and analyzed 39 different PFAS compounds. RESULTS: For the PFAS compounds with concentrations significantly above normal, we observed a removal ratio close to 90% already within the first 60 min of circulation leading to almost complete elimination of all pollutants at 120 min. CONCLUSIONS: The in vitro model of hemoadsorption suggests the possible application in vivo of this technique to reduce/normalize the concentrations of PFAS in patients exposed to water or environmental pollution.


Asunto(s)
Fluorocarburos , Humanos , Fluorocarburos/sangre , Contaminantes Químicos del Agua/sangre , Cinética , Adsorción , Purificación del Agua/métodos
5.
Heart Fail Rev ; 29(3): 615-630, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38289525

RESUMEN

Acute decompensated heart failure and fluid overload are the most common causes of hospitalization in heart failure patients, and often, they contribute to disease progression. Initial treatment encompasses intravenous diuretics although there might be a percentual of patients refractory to this pharmacological approach. New technologies have been developed to perform extracorporeal ultrafiltration in fluid overloaded patients. Current equipment allows to perform ultrafiltration in most hospital and acute care settings. Extracorporeal ultrafiltration is then prescribed and conducted by specialized teams, and fluid removal is planned to restore a status of hydration close to normal. Recent clinical trials and European and North American practice guidelines suggest that ultrafiltration is indicated for patients with refractory congestion not responding to medical therapy. Close interaction between nephrologists and cardiologists may be the key to a collaborative therapeutic effort in heart failure patients. Further studies are today suggesting that wearable technologies might become available soon to treat patients in ambulatory and de-hospitalized settings. These new technologies may help to cope with the increasing demand for the care of chronic heart failure patients. Herein, we provide a state-of-the-art review on extracorporeal ultrafiltration and describe the steps in the development of a new miniaturized system for ultrafiltration, called AD1 (Artificial Diuresis).


Asunto(s)
Insuficiencia Cardíaca , Ultrafiltración , Humanos , Insuficiencia Cardíaca/terapia , Ultrafiltración/métodos , Ultrafiltración/instrumentación , Miniaturización , Diseño de Equipo , Hemofiltración/instrumentación , Hemofiltración/métodos
6.
Cardiorenal Med ; 13(1): 176-183, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37231837

RESUMEN

INTRODUCTION: Fluid overload and congestion are common features in patients with heart failure and are associated with negative clinical outcomes. Therapies for these conditions are diuretic-centered but frequently fail to achieve patient-adequate hydration status, prompting the use of extracorporeal ultrafiltration. Artificial Diuresis 1 (AD1) is a miniaturized, portable, and wearable system designed to deliver isolated ultrafiltration with the finest degree of simplicity and practicality. METHODS/DESIGN: Single-center, crossover, randomized, open-label pilot study to investigate the safety and the efficacy (concerning ultrafiltration accuracy) of extracorporeal ultrafiltration with the device AD1 in comparison to isolated ultrafiltration with a traditional machine (PrisMaX). Patients with chronic kidney disease stage 5D (on hemodialysis) or intensive care patients presenting acute kidney injury stage 3D (requiring hemodialysis) will carry out a single session of isolated ultrafiltration with each of the machines. The safety primary outcomes will be the occurrence of adverse events. The efficacy primary outcome will be the accuracy of ultrafiltration rate (delivered/prescribed) on each of the devices. CONCLUSION: AD1 is a novel miniaturized device for extracorporeal ultrafiltration. This study will be the first-in-human use of AD1 in patients with fluid overload.


Asunto(s)
Insuficiencia Cardíaca , Fallo Renal Crónico , Humanos , Insuficiencia Cardíaca/terapia , Fallo Renal Crónico/terapia , Proyectos Piloto , Ensayos Clínicos Controlados Aleatorios como Asunto , Diálisis Renal , Ultrafiltración/métodos , Estudios Cruzados
7.
Cardiorenal Med ; 13(1): 167-175, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36977396

RESUMEN

INTRODUCTION: We have recently developed a new miniaturized device for extracorporeal ultrafiltration (UF) to be used in patients with fluid overload: Artificial Diuresis-1 (AD1) (Medica S.p.A., Medolla, Italy). The device has a reduced priming volume, operates at very low pressures and flow regimes, and is designed to perform extracorporeal UF at bedside. After accurate experiments were carried out in vitro, we report in this paper the results of in vivo UF sessions carried out in selected animals according to veterinary best practice. MATERIALS AND METHODS: The AD1 kit is pre-filled with sterile isotonic solution and operates with a polysulfone mini-filter, MediSulfone (polysulfone at 50,000 Dalton). A collection bag with a volumetric scale is connected to the UF line, and the ultrafiltrate is obtained by gravity based on the height at which the ultrafiltrate collection bag is placed. Animals were prepared and anesthetized. The jugular vein was cannulated with a double-lumen catheter. Three 6-h sessions of UF were scheduled with a target fluid removal of 1,500 mL. Heparin was used as anticoagulant. RESULTS: In all treatments, the target value of UF was obtained in the absence of major clinical or technical problems with a maximum deviation from the scheduled UF rate lower than 10%. The device resulted to be safe, reliable, accurate, and easily usable thanks to a user-friendly interface and its very small dimensions. CONCLUSIONS: This study opens the way for clinical trials in different settings including departments with low intensity of care and even in ambulatory centers or patient's home.


Asunto(s)
Diuresis , Ultrafiltración , Humanos , Animales , Ultrafiltración/métodos , Anticoagulantes , Italia
8.
Cardiorenal Med ; 13(1): 46-55, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36787707

RESUMEN

INTRODUCTION: Fluid overload has been associated with untoward outcomes in a variety of clinical settings. Isolated extracorporeal ultrafiltration (UF) allows for mechanical extraction of excess fluid and optimization of volume status without the established risks associated with use of high-dose diuretics. Conventional machines for renal replacement therapy can be used to perform isolated UF. However, they typically need high blood flow rates with high circuit volumes and the therapy has to be performed by trained nurses. Herein, we describe a novel device, the Artificial Diuresis-1, or AD 1 (Medica S.p.A., Medolla, Italy), which is a portable technology designed to perform extracorporeal UF at bedside. MATERIALS AND METHODS: The AD 1 uses a polysulfone mini-filter to generate ultrafiltrate with the help of two forces: blood flow (Qb) and gravity (based on the height at which the ultrafiltrate collection bag is placed). In vitro experiments were performed using human blood to evaluate vascular access pressures and ultrafiltrate volumes using various central venous catheters (CVCs; 12 Fr bilume, 10 Fr with 2 separate lumens, pediatric catheter 7 Fr). A variety of combinations were tested with Qb of 20, 35, 50 mL/min and collection bag height at 20, 40, 60 cm, measuring the UF rate per minute while monitoring the pressures in the venous and arterial lines and filtration fraction. RESULTS: The device's performance was as expected. Regarding the pediatric CVC, it was possible to perform measurements only with a Qb of 20 mL/min due to increased venous pressure. UF rates when lines were directly connected to the blood container as well as for CVC Tesio ranged from 3.7 to 11 mL/min, for the CVC Niagara™ from 4.5 to 12.5 mL/min, and for the CVC 7 Fr from 8.5 to 10 mL/min. The pressures of the vascular accesses were kept within a range of -5/-40 mm Hg for the artery and +10/+70 mm Hg for the vein. The highest venous pressure values were found with the CVC 7 Fr (+80/+100 mm Hg). CONCLUSIONS: This novel device allows to treat patients with fluid overload in a variety of settings, from low-intensity department such as long-term care facilities to the intensive care unit. The device is small and portable, has a simple design, and is user friendly. Future studies will be needed to evaluate whether gentle UF and treatment of volume overload will translate into improvement in clinical outcomes such as a reduction in congestion-related hospital admissions.


Asunto(s)
Insuficiencia Cardíaca , Ultrafiltración , Humanos , Niño , Terapia de Reemplazo Renal , Hemodinámica , Diuréticos
9.
Cardiorenal Med ; 2022 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-36521449

RESUMEN

Fluid overload in different acute or chronic clinical settings results in unfavorable outcomes. The use of restrictive strategies for fluid control or the use of diuretics is frequently ineffective and requires extracorporeal ultrafiltration for the removal of excess volume. These extracorporeal treatments are performed with bulky machinery and require highly specialized personnel. The creation of a miniaturized device for extracorporeal ultrafiltration (Artificial Diuresis) would fill the technological gap in this sector by responding to the needs of cost containment and rehabilitation of the patient. In this article we explain the rationale that led to the design of this device.

10.
Blood Purif ; 51(11): 912-922, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35263746

RESUMEN

INTRODUCTION: At the time of renal replacement therapy, approximately 20% of critically ill patients have septic shock. In this study, medium cutoff (MCO) continuous venovenous hemodialysis (CVVHD) was compared to high-flux membrane continuous venovenous hemodiafiltration (CVVHDF) in terms of hemodynamic improvement, efficiency, middle molecule removal, and inflammatory system activation. METHODS: This is a monocenter crossover randomized study. Between December 31, 2017, and December 31, 2019, 20 patients with septic shock and stage 3 acute kidney injury (AKI) admitted to 2 Italian ICUs were enrolled. All patients underwent CVVHD with Ultraflux® EMiC®2 and CVVHDF with AV1000S® without washout. Each treatment lasted 24 h. RESULTS: Compared to AV1000S®-CVVHDF, EMIC®2-CVVHD normalized cardiac index (ß = -0.64; p = 0.02) and heart rate (ß = 5.72; p = 0.01). Interleukin-8 and myeloperoxidase removal were greater with AV1000S®-CVVHDF than with EMiC®2-CVVHD (ß = 0.35; p < 0.001; ß = 0.43; p = 0.03, respectively). Leukocytosis improved over 24 h in EMiC®2-CVVHD-treated patients (ß = 4.13; p = 0.03), whereas procalcitonin levels decreased regardless of the modality (ß = 0.89; p = 0.01) over a 48-h treatment period. Reduction rates, instantaneous plasmatic clearance of urea, creatinine, and ß2-microglobulin were similar across modalities. ß2-Microglobulin removal efficacy was greater in the EMiC®2 group (ß = 0-2.88; p = 0.002), while albumin levels did not differ. Albumin was undetectable in the effluent in both treatments. DISCUSSION: In patients with septic shock and severe AKI, the efficacy of uremic toxin removal was comparable between MCO-CVVHD and CVVHDF. Further, MCO-CVVHD was associated with improved hemodynamics. Fraction of filtration and transmembrane pressure reduction and the maintenance of equal efficacy might be the key features of CVVHD with MCO membranes in critically ill patients.


Asunto(s)
Lesión Renal Aguda , Terapia de Reemplazo Renal Continuo , Hemodiafiltración , Choque Séptico , Humanos , Choque Séptico/terapia , Choque Séptico/etiología , Enfermedad Crítica , Diálisis Renal , Lesión Renal Aguda/terapia , Albúminas , Hemodiafiltración/efectos adversos
11.
Clin Chem Lab Med ; 59(2): 333-342, 2020 09 28.
Artículo en Inglés | MEDLINE | ID: mdl-32986608

RESUMEN

Objectives: Identification of acute kidney injury (AKI) can be challenging in patients with a variety of clinical features at intensive care unit (ICU) admission, and the capacity of biomarkers in this subpopulation has been poorly studied. In our study we examined the influence that patients' clinical features at ICU admission have over the predicting ability of the combination of urinary tissue inhibitor of metalloproteinase-2 (TIMP2) and insulin-like growth factor binding protein 7 (IGFBP7). Methods: Urinary [TIMP2]•[IGFBP7] were measured for all patients upon admission to ICU. We calculated the receiver operating characteristics (ROC) curves for AKI prediction in the overall cohort and for subgroups of patients according to etiology of ICU admission, which included: sepsis, trauma, neurological conditions, cardiovascular diseases, respiratory diseases, and non-classifiable causes. Results: In the overall cohort of 719 patients, 239 (33.2%) developed AKI in the first seven days. [TIMP2]•[IGFBP7] at ICU admission were significantly higher in AKI patients than in non-AKI patients. This is true not only for the overall cohort but also in the other subgroups. The area under the ROC curve (AUC) for [TIMP2]•[IGFBP7] in predicting AKI in the first seven days was 0.633 (95% CI 0.588-0.678), for the overall cohort, with sensitivity and specificity of 66.1 and 51.9% respectively. When we considered patients with combined sepsis, trauma, and respiratory disease we found a higher AUC than patients without these conditions (0.711 vs. 0.575; p=0.002). Conclusions: The accuracy of [TIMP2]•[IGFBP7] in predicting the risk of AKI in the first seven days after ICU admission has significant variability when the reason for ICU admission is considered.


Asunto(s)
Lesión Renal Aguda/diagnóstico , Biomarcadores/análisis , Puntos de Control del Ciclo Celular/fisiología , Unidades de Cuidados Intensivos/normas , Anciano , Estudios de Cohortes , Femenino , Hospitalización , Humanos , Proteínas de Unión a Factor de Crecimiento Similar a la Insulina/sangre , Proteínas de Unión a Factor de Crecimiento Similar a la Insulina/orina , Masculino , Persona de Mediana Edad , Curva ROC , Medición de Riesgo , Sensibilidad y Especificidad , Inhibidor Tisular de Metaloproteinasa-2/sangre , Inhibidor Tisular de Metaloproteinasa-2/orina
12.
World J Clin Cases ; 8(9): 1600-1607, 2020 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-32432138

RESUMEN

BACKGROUND: Acute cardiorenal syndrome type 1 (CRS-1) is defined by a rapid cardiac dysfunction leading to acute kidney injury (AKI). Neutrophil gelatinase-associated lipocalin (NGAL) is expressed on the surface of human neutrophils and epithelial cells, such as renal tubule cells, and its serum (sNGAL) and urinary have been used to predict AKI in different clinical settings. AIM: To characterize CRS-1 in a cohort of patients with acute heart diseases, evaluating the potentiality of sNGAL as an early marker of CRS-1. METHODS: We performed a retrospective cohort, multi-centre study. From January 2010 to December 2011, we recruited 202 adult patients admitted to the coronary intensive care unit (CICU) with a diagnosis of acute heart failure or acute coronary syndrome. We monitored the renal function to evaluate CRS-1 development and measured sNGAL levels within 24 h and after 72 h of CICU admission. RESULTS: Overall, enrolled patients were hemodynamically stable with a mean arterial pressure of 92 (82-107) mmHg, 55/202 (27.2%) of the patients developed CRS-1, but none of them required dialysis. Neither the NGAL delta value (AUC 0.40, 95%CI: 0.25-0.55) nor the NGAL peak (AUC 0.45, 95%CI: 0.36-0.54) or NGAL cut-off (≥ 140 ng/mL) values were statistically significant between the two groups (CRS-1 vs no-CRS1 patients). The area under the ROC curve for the prediction of CRS-1 was 0.40 (95%CI: 0.25-0.55) for the delta NGAL value and 0.45 (95%CI: 0.36-0.54) for the NGAL peak value. Finally, in multivariate analysis, the risk of developing CRS-1 was correlated with age > 60 years, urea nitrogen at admission and 24 h-urine output (AUC 0.83, SE = 60.5% SP = 93%), while sNGAL was not significantly correlated. CONCLUSION: In our population, sNGAL does not predict CRS-1, probably as a consequence of the mild renal injury and the low severity of heart disease. So, these data might suggest that patient selection should be taken into account when considering the utility of NGAL measurement as a biomarker of kidney damage.

13.
Sci Rep ; 9(1): 16484, 2019 11 11.
Artículo en Inglés | MEDLINE | ID: mdl-31712687

RESUMEN

The urinary tissue inhibitor of metalloproteinases-2 and insulin-like growth factor-binding protein 7 ([TIMP-2]∙[IGFBP7]) have been introduced to improve risk prediction of severe acute kidney injury (AKI) within 12 hours of measurement. We performed a prospective cohort study to evaluate if the predictive value of [TIMP-2]∙[IGFBP7] for AKI might continue after 12 hours. We enrolled 442 critically ill adult patients from June to December 2016. Urine samples were collected at admission for [TIMP-2]∙[IGFBP7] measurement. Baseline patient characteristics were recorded including patients' demographics, prior health history, and the main reason for admission to build a logistic regression model to predict AKI. AKI occurrence differed between patients with [TIMP-2]∙[IGFBP7] ≤0.3 and >0.3 (ng/ml)2/1000 (31.9% and 68.10% respectively; p < 0.001). Patients with AKI had higher biomarker values compared to those without AKI (0.66 (0.21-2.84) vs 0.22 (0.08-0.63) (ng/ml)2/1000; p < 0.001). [TIMP-2]∙[IGFBP7] at ICU admission had a lower performance in predicting AKI at any stage within 48 hours and 7 days after measurement (area under the receiver operating characteristic curve (AUC) equal to 0.70 (95%CI 0.65-0.76), AUC 0.68 (95%CI 0.63-0.73)). In the logistic regression model, 0.1 (ng/ml)2/1000-unit increment was likely to increase the risk of AKI by 2% (p = 0.002).


Asunto(s)
Lesión Renal Aguda/diagnóstico , Lesión Renal Aguda/orina , Biomarcadores , Inhibidor Tisular de Metaloproteinasa-2/orina , Lesión Renal Aguda/etiología , Adulto , Anciano , Anciano de 80 o más Años , Cuidados Críticos , Femenino , Hospitalización , Humanos , Unidades de Cuidados Intensivos , Pruebas de Función Renal , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Curva ROC , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo
14.
PLoS One ; 14(6): e0217424, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31220087

RESUMEN

AKI is associated with increased risk of death, prolonged length of stay and development of de-novo chronic kidney disease. The aim of our study is the development and validation of prediction models to identify the risk of AKI in ICU patients up to 7 days. We retrospectively recruited 692 consecutive patients admitted to the ICU at San Bortolo Hospital (Vicenza, Italy) from 1 June 2016 to 31 March 2017: 455 patients were treated as the derivation group and 237 as the validation group. Candidate variables were selected based on a literature review and expert opinion. Admission eGFR< 90 ml/min /1.73 mq (OR 2.78; 95% CI 1.78-4.35; p<0.001); SOFAcv ≥ 2 (OR 2.23; 95% CI 1.48-3.37; p<0.001); lactate ≥ 2 mmol/L (OR 1.81; 95% CI 1.19-2.74; p = 0.005) and (TIMP-2)•(IGFBP7) ≥ 0.3 (OR 1.65; 95% CI 1.08-2.52; p = 0.019) were significantly associated with AKI. For the q-AKI score, we stratified patients into different AKI Risk score levels: 0-2; 3-4; 5-6; 7-8 and 9-10. In both cohorts, we observed that the proportion of AKI patients was higher in the higher score levels.


Asunto(s)
Lesión Renal Aguda , Cuidados Críticos , Tasa de Filtración Glomerular , Unidades de Cuidados Intensivos , Sistema de Registros , Lesión Renal Aguda/diagnóstico , Lesión Renal Aguda/fisiopatología , Lesión Renal Aguda/orina , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
15.
Kidney Int ; 95(6): 1486-1493, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30982674

RESUMEN

The G1 cell cycle inhibitors tissue inhibitor metalloproteinase-2 (TIMP-2) and insulin-like growth factor-binding protein 7 (IGFBP7) have been identified as novel biomarkers for the prediction of moderate to severe acute kidney injury (AKI) risk. However, the prognostic value of [TIMP-2]•[IGFBP7] in predicting adverse outcomes in intensive care unit (ICU) patients with AKI was not previously described. To evaluate this, we conducted a cohort study, measuring [TIMP2]•[IGFBP7] levels in critically ill patients admitted to the ICU and classified the patients as NephroCheck (NC) (+) or NC (-) according to [TIMP-2]•[IGFBP7] values and AKI (+) or AKI (-) according to Kidney Disease: Improving Global Outcomes (KDIGO) criteria. We then evaluated the incidence of continuous renal replacement therapy initiation, all-cause mortality and a composite endpoint of both in the four groups. Baseline [TIMP-2]•[IGFBP7] values were available for 719 patients, of whom 239 developed AKI and 151 met the composite endpoint. Compared to NC (-)/AKI (+) patients, NC (+)/AKI (+) patients had a significant risk of ICU mortality and the composite endpoint. Kaplan-Meier curves showed that the survival estimate for the composite endpoint of NC (+)/AKI (+) patients was 34.4%; significantly worse than NC (-)/AKI (+) patients (67.4%). Multivariate analyses showed strong association between NC positivity and the composite endpoint. The inflammatory marker, procalcitonin, was an additional prognostic biomarker to compare and confirm the incremental value of NephroCheck. No association between procalcitonin and the composite endpoint was found, especially in patients with AKI, suggesting that NephroCheck may be more kidney specific. Thus, the [TIMP-2]•[IGFBP7] values can serve to identify patients with AKI at increased risk for adverse outcomes in the ICU.


Asunto(s)
Lesión Renal Aguda/diagnóstico , Proteínas de Unión a Factor de Crecimiento Similar a la Insulina/sangre , Unidades de Cuidados Intensivos/estadística & datos numéricos , Inhibidor Tisular de Metaloproteinasa-2/sangre , Lesión Renal Aguda/sangre , Lesión Renal Aguda/mortalidad , Lesión Renal Aguda/terapia , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Estudios de Factibilidad , Femenino , Mortalidad Hospitalaria , Humanos , Italia/epidemiología , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Estudios Prospectivos , Curva ROC , Terapia de Reemplazo Renal/estadística & datos numéricos , Medición de Riesgo/métodos , Índice de Severidad de la Enfermedad
16.
Blood Purif ; 48(1): 60-66, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30712031

RESUMEN

BACKGROUND: ACUsmart (Medica S.P.A., Italy) is a new-generation, continuous renal replacement therapy (CRRT) machine for critically ill patients with acute kidney injury. We designed a multicenter international pilot study to provide a description of outlines of the ACUsmart system, evaluation aspects of functionality, usability, and feasibility, discriminating reasons of possible treatment's withdrawals or discontinuations and highlighting strong and weak points of the machine. METHODS: Data of 23 CRRT (and 11 plasma exchange) treatments were collected from 4 intensive care units. Parameters such as treatment duration, downtime, delivered dose, and number and type of alarms were recorded. The general perception of the machine was quantified through the administration of a survey to each component of the evaluating staff. RESULTS: A total treatment time of 447 h was carried with ACUsmart. Eleven continuous veno-venous hemofiltration, 4 continuous veno-venous hemodialysis , and 8 continuous veno-venous hemodiafiltration were performed. The average percentage of net treatment duration with respect to total treatment duration was 92.37%. The mean prescribed dose and delivered dose were 26.33 and 24.10 mL/kg/h, respectively. In general, the machine was rated by users involved as practical and easy to use, although few components need to be slightly improved. CONCLUSION: ACUsmart is a new multifunctional machine that meets most of the features required in a fourth-generation CRRT equipment.


Asunto(s)
Lesión Renal Aguda/terapia , Enfermedad Crítica/terapia , Terapia de Reemplazo Renal/instrumentación , Terapia de Reemplazo Renal/métodos , Humanos , Proyectos Piloto , Terapia de Reemplazo Renal/efectos adversos , Proyectos de Investigación , Resultado del Tratamiento , Interfaz Usuario-Computador
17.
Blood Purif ; 47(1-3): 270-276, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30522094

RESUMEN

BACKGROUND: Sepsis is a life-threatening condition often associated with a high incidence of multiple organs injury. Several papers suggested the immune response by itself, with the production of humoral inflammatory mediators, is crucial in determining organ injury. However, little is known of how sepsis directly induces organ injury at the cellular levels. To assess this point, we set up an in vitro study to investigate the response of renal tubular cells (RTCs), monocytes (U937) and hepatocytes (HepG2) after 24 h-incubation with septic patients' plasma. METHODS: We enrolled 26 septic patients ("test" group). We evaluated cell viability, apoptosis and necrosis by flow cytometer. Caspase-3,-8,-9 and cytochrome-c concentrations have been analyzed using the Human enzyme-linked immunosorbent assay kit. RESULTS: We found that a decrease of cell viability in all cell lines tested was associated to the increase of apoptosis in RTCs and U937 (p < 0.0001) and increase of necrosis in HepG2 (p < 0.5). The increase of apoptosis in RTCs and U937 cells was confirmed by higher levels of caspase-3 (p < 0.0001). We showed that apoptosis in both RTCs and U937 was triggered by the activation of the intrinsic pathway, as caspase-9 and cytochrome-c levels significantly increased (p < 0.0001), while caspase-8 did not change. This assumption was strengthened by the significant correlation of caspase-9 with both cytochrome-c (r = 0.73 for RTCs and r = 0.69 for U937) and caspase-3 (r = 0.69 for RTCs and r = 0.63 for U937). CONCLUSION: Humoral mediators in septic patients' plasma induce apoptosis. This fact suggests that apoptosis inhibitors should be investigated as future strategy to reduce sepsis-induced organ damages.


Asunto(s)
Apoptosis , Hepatocitos/metabolismo , Túbulos Renales Proximales/metabolismo , Monocitos/metabolismo , Plasma , Sepsis/sangre , Caspasas/metabolismo , Supervivencia Celular , Citocromos c/metabolismo , Células Hep G2 , Hepatocitos/patología , Humanos , Túbulos Renales Proximales/patología , Monocitos/patología , Células U937
18.
Nephrol Dial Transplant ; 34(2): 308-317, 2019 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-30053231

RESUMEN

Background: Cardiac surgery is a leading cause of acute kidney injury (AKI). Such AKI patients may develop progressive chronic kidney disease (CKD). Others, who appear to have sustained no permanent loss of function (normal serum creatinine), may still lose renal functional reserve (RFR). Methods: We extended the follow-up in the observational 'Preoperative RFR Predicts Risk of AKI after Cardiac Surgery' study from hospital discharge to 3 months after surgery for 86 (78.2%) patients with normal baseline estimated glomerular filtration rate (eGFR), and re-measured RFR with a high oral protein load. The primary study endpoint was change in RFR. Study registration at clinicaltrials.gov Identifier: NCT03092947, ISRCTN Registry: ISRCTN16109759. Results: At 3 months, three patients developed new CKD. All remaining patients continued to have a normal eGFR (93.3 ± 15.1 mL/min/1.73 m2). However, when stratified by post-operative AKI and cell cycle arrest (CCA) biomarkers, AKI patients displayed a significant decrease in RFR {from 14.4 [interquartile range (IQR) 9.5 - 24.3] to 9.1 (IQR 7.1 - 12.5) mL/min/1.73 m2; P < 0.001} and patients without AKI but with positive post-operative CCA biomarkers also experienced a similar decrease of RFR [from 26.7 (IQR 22.9 - 31.5) to 19.7 (IQR 15.8 - 22.8) mL/min/1.73 m2; P < 0.001]. In contrast, patients with neither clinical AKI nor positive biomarkers had no such decrease of RFR. Finally, of the three patients who developed new CKD, two sustained AKI and one had positive CCA biomarkers but without AKI. Conclusions: Among elective cardiac surgery patients, AKI or elevated post-operative CCA biomarkers were associated with decreased RFR at 3 months despite normalization of serum creatinine. Larger prospective studies to validate the use of RFR to assess renal recovery in combination with biochemical biomarkers are warranted.


Asunto(s)
Lesión Renal Aguda/etiología , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Cardiopatías/complicaciones , Cardiopatías/cirugía , Insuficiencia Renal Crónica/etiología , Biomarcadores/sangre , Creatinina/sangre , Femenino , Estudios de Seguimiento , Tasa de Filtración Glomerular , Humanos , Riñón/fisiopatología , Pruebas de Función Renal , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Periodo Posoperatorio , Estudios Prospectivos
19.
Blood Purif ; 47(1-3): 140-148, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30336490

RESUMEN

Backgound: This study was aimed at evaluating the presepsin and procalcitonin levels to predict adverse postoperative complications and mortality in cardiac surgery patients. METHODS: A total of 122 cardiac surgery patients were enrolled for the study. Presepsin and procalcitonin levels were measured 48 h after the procedure. The primary endpoints were adverse renal, respiratory, and cardiovascular outcomes and mortality. RESULTS: Presepsin and procalcitonin levels were significantly higher in patients with adverse renal and respiratory outcome (p < 0.001 and 0.0081). The presepsin levels were significantly higher in patients with adverse cardiovascular outcome (p = 0.023) and the procalcitonin values in patients with sepsis (p = 0.0013). Presepsin levels were significantly higher in patients who died during hospitalization (382 pg/mL, interquartile range [IQR] 243-717.5 vs. 1,848 pg/mL, IQR 998-5,451.5, p = 0.049). In addition, the predictive value for in-hospital, 30-days, and 6-months mortality was higher for presepsin, with a significant difference between the 2 biomarkers (p = 0.025, p = 0.035, p = 0.003; respectively). Presepsin and procalcitonin seem to have comparable predictive value for adverse renal, cardiovascular, and respiratory outcome in cardiac surgery patients. Although a positive trend was notable for presepsin and adverse renal outcome (area under the ROC [receiver operating characteristic] curves [AUC] of 0.760, 95% CI 0.673-0.833 versus procalcitonin: AUC 0.692; 95% CI 0.601-0.773): no statistically significant difference was evident between the AUC of the 2 biomarkers (p = 0.25). CONCLUSIONS: Presepsin and -procalcitonin seem to have comparable predictive value for -adverse renal, cardiovascular, and respiratory outcome in cardiac surgery patients. Also, presepsin possesses a better predictive value for in-hospital, 30-days, and 6-months mortality.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/efectos adversos , Mortalidad Hospitalaria , Receptores de Lipopolisacáridos/sangre , Fragmentos de Péptidos/sangre , Complicaciones Posoperatorias/sangre , Complicaciones Posoperatorias/mortalidad , Polipéptido alfa Relacionado con Calcitonina/sangre , Anciano , Biomarcadores/sangre , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Tiempo
20.
Nephrol Dial Transplant ; 33(suppl_3): iii41-iii47, 2018 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-30281134

RESUMEN

Recent advances in chemical composition and new production techniques resulted in improved biocompatibility and permeability of dialysis membranes. Among these, the creation of a new class of membranes called medium cut-off (MCO) represents an important step towards improvement of clinical outcomes. Such membranes have been developed to improve the clearance of medium to high molecular weight (MW) solutes (i.e. uraemic toxins in the range of 5-50 kDa). MCO membranes have peculiar retention onset and cut-off characteristics. Due to a modified sieving profile, MCO membranes have also been described as high-retention onset. The significant internal filtration achieved in MCO haemodialysers provides a remarkable convective clearance of medium to high MW solutes. The marginal loss of albumin observed in MCO membranes compared with high cut-off membranes is considered acceptable, if not beneficial, producing a certain clearance of protein-bound solutes. The application of MCO membranes in a classic dialysis modality characterizes a new technique called expanded haemodialysis. This therapy does not need specific software or dedicated hardware, making its application possible in every setting where the quality of dialysis fluid meets current standards.


Asunto(s)
Hemodiafiltración/instrumentación , Membranas Artificiales , Diálisis Renal/instrumentación , Diálisis Renal/métodos , Soluciones para Diálisis , Hemodiafiltración/métodos , Humanos , Peso Molecular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA