Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Ann Vasc Surg ; 74: 294-300, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33508454

RESUMEN

BACKGROUND: This study sought to define duplex ultrasound (DUS) velocity criteria predicting ≥70% stenosis in superior mesenteric artery (SMA) stents by correlating in-stent peak systolic velocity (PSV) with computed tomographic angiography (CTA) measurements of percent stenosis. METHODS: A retrospective review of 109 patients undergoing SMA stenting between 2003 and 2018 was conducted at a single institution. Thirty-seven surveillance duplex ultrasound studies were found to have a CTA performed within 30 days of study completion. Bare metal (n = 20) and covered stents (n = 17) were included. Velocities were paired to in-stent restenosis (ISR) measured by mean vessel diameter reduction on SMA centerline reconstructions from CTA. Receiver operating characteristic (ROC) curves was generated and logistic regression models for ≥70% ISR probability were used to define velocity criteria in the stented SMA. RESULTS: At a PSV of 300 cm/sec, the sensitivity is 100% and specificity 80% for a ≥70% in-stent SMA stenosis. At a PSV of 400 cm/sec, the sensitivity and positive predictive value (PPV) is 63% and the specificity and negative predictive value (NPV) is 90%. A PSV of 450 cm/sec was consistent with the highest specificity (100%) and PPV (100%) but lower sensitivity (50%) and NPV (87.9%). One patient with a PSV of 441 cm/sec on surveillance DUS died from complications of acute-on-chronic mesenteric ischemia. CONCLUSIONS: A PSV of 400 cm/sec on mesenteric DUS can predict ≥70% ISR with high sensitivity and should be considered as a diagnostic threshold for SMA in-stent restenosis.


Asunto(s)
Procedimientos Endovasculares/instrumentación , Arteria Mesentérica Superior/diagnóstico por imagen , Isquemia Mesentérica/terapia , Oclusión Vascular Mesentérica/terapia , Stents , Ultrasonografía Doppler Dúplex , Anciano , Anciano de 80 o más Años , Velocidad del Flujo Sanguíneo , Enfermedad Crónica , Angiografía por Tomografía Computarizada , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Masculino , Arteria Mesentérica Superior/fisiopatología , Isquemia Mesentérica/diagnóstico por imagen , Isquemia Mesentérica/fisiopatología , Oclusión Vascular Mesentérica/diagnóstico por imagen , Oclusión Vascular Mesentérica/fisiopatología , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Recurrencia , Reproducibilidad de los Resultados , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Circulación Esplácnica , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA