Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Am Soc Echocardiogr ; 36(4): 381-390, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36610496

RESUMEN

BACKGROUND: Transesophageal echocardiograms (TEEs) performed during transcatheter structural cardiac interventions may result in greater complications than those performed in the nonoperative setting or even those performed during cardiac surgery. However, there are limited data on complications associated with TEE during these procedures. We evaluated the prevalence of major complications among these patients in the United States. METHODS: A retrospective cohort study was conducted using an electronic health record database (TriNetX Research Network) from large academic medical centers across the United States for patients undergoing TEE during transcatheter structural interventions from January 2012 to January 2022. Using the American Society of Echocardiography-endorsed International Statistical Classification of Diseases and Related Health Problems Clinical Modifications (10th edition) codes, patients undergoing TEE during a transcatheter structural cardiac intervention, including transaortic, mitral or tricuspid valve repair, left atrial appendage occlusion, atrial septal defect closure, patent foramen ovale closure, and paravalvular leak repair, were identified. The primary outcome was major complications within 72 hours of the procedure (composite of bleeding and esophageal and upper respiratory tract injury). The secondary aim was the frequency of major complications, death, or cardiac arrest within 72 hours in patients who completed intraoperative TEE during surgical valve replacement. RESULTS: Among 12,043 adult patients (mean age, 74 years old; 42% female) undergoing TEE for transcatheter structural cardiac interventions, 429 (3.6%) patients had a major complication. Complication frequency was higher in patients on anticoagulation or antiplatelet therapy compared with those not on therapy (3.9% vs 0.5%; risk ratio [RR] = 8.09, P < .001). Compared with those patients <65 years of age, patients ≥65 years of age had a higher frequency of major complications (3.9% vs 2.2%; RR = 1.75, P < .001). Complication frequency was similar among male and female patients (3.5% vs 3.7%; RR = 0.96, P = .67). Among 28,848 patients who completed surgical valve replacement with TEE guidance, 728 (2.5%) experienced a major complication. CONCLUSIONS: This study found that more than 3% of patients undergoing TEE during transcatheter structural cardiac interventions have a major complication, which is more common among those on anticoagulant or antiplatelet therapy or who are elderly. With a shift of poor surgical candidates to less invasive percutaneous procedures, the future of TEE-guided procedures relies on comprehensive risk discussion and updating practices beyond conventional methods to minimize risk for TEE-related complications.


Asunto(s)
Ecocardiografía Transesofágica , Defectos del Tabique Interatrial , Adulto , Humanos , Masculino , Femenino , Anciano , Ecocardiografía Transesofágica/métodos , Estudios Retrospectivos , Inhibidores de Agregación Plaquetaria , Corazón , Ecocardiografía/métodos , Defectos del Tabique Interatrial/cirugía , Cateterismo Cardíaco/métodos , Resultado del Tratamiento
2.
Eur Heart J Cardiovasc Imaging ; 18(12): 1404-1413, 2017 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-28165129

RESUMEN

AIMS: The use of contrast media with multidetector computed tomography (MDCT) may induce acute kidney injury in patients with renal failure undergoing transcatheter aortic valve replacement (TAVR). We investigated the role of large-field intravascular ultrasound (IVUS) vs. MDCT and two-dimensional transoesophageal echocardiography (2D-TEE) for annular sizing and predicting paravalvular regurgitation (PVR) during TAVR. METHODS AND RESULTS: The aortic annulus was measured by large-field IVUS and 2D-TEE, and compared with MDCT in 50 patients undergoing TAVR. The IVUS and MDCT annular areas and diameters were not significantly different (446 ± 87 mm2 and 23.8 ± 84 mm vs. 466 ± 84 mm2 and 24 ± 2.1 mm, respectively; P > 0.05). IVUS and MDCT mean annular diameters were significantly greater than TEE diameter (23.8 ± 2.4 and 24 ± 2.1 vs. 22 ± 0.65 mm, respectively; P < 0.01). PVR ≥ Mild occurred in 13 patients (26%); 5 patients required post-dilation and 2 patients a second valve. Receiver operating characteristic analyses showed that transcatheter heart valve (THV) area - IVUS or MDCT areas equally predicted of ≥ mild PVR (areas under the curve [AUC] 0.79 and 0.81, respectively; P < 0.001), and were greater than THV diameter-TEE diameter (AUC 0.79 and 0.81 vs. 0.56, respectively; P < 0.05). CONCLUSIONS: The aortic annular measurements and predicting PVR by large field IVUS were not significantly different from those of MDCT, but were greater than those of TEE. Large filed IVUS can be reliably used in lieu of MDCT for annular sizing in patients with aortic stenosis and renal failure or suboptimal MDCT images.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Ecocardiografía Transesofágica/métodos , Complicaciones Intraoperatorias/diagnóstico por imagen , Tomografía Computarizada Multidetector/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Ultrasonografía Intervencional/métodos , Análisis de Varianza , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Área Bajo la Curva , Distribución de Chi-Cuadrado , Estudios de Cohortes , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Pronóstico , Estudios Prospectivos , Curva ROC , Medición de Riesgo , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
3.
J Am Coll Surg ; 222(4): 645-55, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26905186

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) was FDA approved for the Sapien valve (Edwards Lifesciences) in the United States in November 2011. We sought to examine the impact of TAVR post-FDA approval on aortic valve surgery at our institution. STUDY DESIGN: Prospective data were collected on 573 consecutive patients that underwent surgical aortic valve replacement (SAVR) or TAVR with either the Sapien or Sapien XT from January 1, 2009 through December 31, 2014. RESULTS: Patients were divided into the following groups: SAVR before TAVR (n = 215), SAVR post TAVR (n = 163), and TAVR (n = 195). The 30-day mortality was not different among the 3 groups, but the mortality for the SAVR post TAVR group was better than the SAVR before TAVR group (p = 0.03). Postoperative hospital length of stay, ventilation hours, and atrial fibrillation were all decreased in the TAVR group. The number of isolated SAVRs increased after TAVR from 60 per year in group 1 to 67 per year in group 2. The total number of all isolated aortic valve procedures (SAVR + TAVR) increased from 60 per year to 177 per year. The TAVR group was divided into the following subgroups to examine the procedural learning curve: patients 1 to 50, patients 51 to 100, and patients 101 to 195. Mortality was higher in group 1 (8%) vs group 2 (0%) and group 3 (1%). CONCLUSIONS: Since initiation of the TAVR program at our institution, the total number of aortic valve procedures has increased. Transcatheter aortic valve replacement patients had more preoperative comorbidities, but no difference in postoperative morbidity or mortality and shorter length of stay. Transcatheter aortic valve replacement mortality has continued to improve since the inception of the program.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Centros de Atención Terciaria , Reemplazo de la Válvula Aórtica Transcatéter/estadística & datos numéricos , Adulto , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/mortalidad , Estudios de Cohortes , Femenino , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
4.
Echocardiography ; 32 Suppl 2: S177-88, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24888693

RESUMEN

Ebstein's anomaly is a complex congenital lesion which primarily involves the tricuspid valve. The tricuspid leaflets are tethered to varying degrees to the right ventricular free wall and the ventricular septum often resulting in significant tricuspid regurgitation and a small functioning right ventricular chamber. Although the septal leaflet originates normally at the right atrioventricular junction, the proximal portion is often completely tethered to the ventricular septum resulting in a misconception and erroneous statements in many publications that its attachment is apically displaced. Although two-dimensional echocardiography represents the primary modality for the diagnosis of this anomaly, three-dimensional echocardiography provides incremental value in characterizing the extent and severity of tethering of individual tricuspid valve leaflets. This information is useful in surgical decision making whether to repair or replace the tricuspid valve.


Asunto(s)
Anomalía de Ebstein/diagnóstico por imagen , Ecocardiografía Tridimensional/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Anomalía de Ebstein/fisiopatología , Anomalía de Ebstein/cirugía , Ecocardiografía/métodos , Femenino , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Complicaciones Posoperatorias/fisiopatología , Complicaciones Posoperatorias/terapia , Medición de Riesgo , Resultado del Tratamiento , Válvula Tricúspide/fisiopatología
5.
Int J Cardiovasc Imaging ; 30(1): 109-19, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24122452

RESUMEN

Vasodilator stress cardiac magnetic resonance (CMR) detects ischemia whereas coronary CT angiography (CTA) detects atherosclerosis. The purpose of this study was to determine concordance and accuracy of vasodilator stress CMR and coronary CTA in the same subjects. We studied 151 consecutive subjects referred to detect or exclude suspected obstructive coronary artery disease (CAD) in patients without known disease or recurrent stenosis or ischemia in patients with previously treated CAD. Vasodilator stress CMR was performed on a 1.5 T scanner. CTA was performed on a 320-detector row system. Subjects were followed for cardiovascular events and downstream diagnostic testing. Subjects averaged 56 ± 12 years (60% male), and 62 % had intermediate pre-test probability for obstructive CAD. Follow-up averaged 450 ± 115 days and was 100% complete. CMR and CTA agreed in 92% of cases (κ 0.81, p < 0.001). The event-free survival was 97 % for non-ischemic and 39% for ischemic CMR (p < 0.0001). The event-free survival was 99% for non-obstructive and 36% for obstructive CTA (p < 0.0001). Using a reference standard including quantitative invasive angiography or major cardiovascular events, CMR and CTA had respective sensitivities of 93 and 98 %; specificities of 96 and 96%; positive predictive values of 91 and 91%; negative predictive values of 97 and 99%; and accuracies of 95 and 97%. Non-ischemic vasodilator stress CMR or non-obstructive coronary CTA were highly concordant and each confer an excellent prognosis. CMR and CTA are both accurate for assessment of obstructive CAD in a predominantly intermediate risk population.


Asunto(s)
Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Vasos Coronarios , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada Multidetector , Imagen de Perfusión Miocárdica/métodos , Vasodilatadores/uso terapéutico , Adulto , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/patología , Enfermedad de la Arteria Coronaria/fisiopatología , Circulación Coronaria , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Vasos Coronarios/fisiopatología , Supervivencia sin Enfermedad , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA