1.
Monoclon Antib Immunodiagn Immunother ; 43(4): 119-126, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39034896

RESUMEN

Mammalian cell line stability is an important consideration when establishing a biologics manufacturing process in the biopharmaceutical and in vitro diagnostics (IVD) industries. Traditional Chinese hamster ovary (CHO) cell line development methods use a random integration approach that requires transfection, selection, optional amplification, screenings, and single-cell cloning to select clones with acceptable productivity, product quality, and genetic stability. Site-specific integration reduces these disadvantages, and new technologies have been developed to mitigate risks associated with genetic instability. In this study, we applied the Leap-In® transposase-mediated expression system from ATUM to generate stable CHOK1 pools for the production of four recombinant antibody reagents for IVD immunoassays. CHO cell line stability is defined by consistent antibody production over time. Three of the CHOK1 pools maintained productivity suitable for manufacturing, with high antibody yields. The productivity of the remaining CHOK1 pool decreased over time; however, derivative clones showed acceptable stability. l-glutamine had variable effects on CHOK1 cell line or stable pool stability and significantly affected antibody product titer. Compared with traditional random integration methods, the ATUM Leap-In system can reduce the time needed to develop new immunoassays by using semi site-specific integration to generate high-yield stable pools that meet manufacturing stability requirements.


Asunto(s)
Cricetulus , Proteínas Recombinantes , Células CHO , Animales , Proteínas Recombinantes/genética , Proteínas Recombinantes/inmunología , Proteínas Recombinantes/biosíntesis , Anticuerpos Monoclonales/biosíntesis , Anticuerpos Monoclonales/inmunología , Anticuerpos Monoclonales/genética , Cricetinae , Humanos , Transposasas/genética , Transposasas/metabolismo
2.
Pract Lab Med ; 34: e00308, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36713933

RESUMEN

Objectives: Cancer antigen (CA) 72-4 assay is widely used for monitoring gastric and ovarian cancers. The antigen is a mucin-like, tumor-associated glycoprotein known as TAG-72. It has been identified and characterized using two different monoclonal antibodies, CC49 and B72.3, which recognize its glycochain epitopes, Galß(1-3) sialyl-Tn and sialyl-Tn antigens, respectively. This study describes the quantitative analytical performance of a newly developed CA 72-4 assay, ARCHITECT CA 72-4. Design: and Methods: The ARCHITECT CA 72-4 assay was developed using the ARCHITECT i2000SRs and three ARCHITECT i1000SRs. The assay performance was evaluated based on guidance from CLSI (Clinical and Laboratory Standards Institute) and correlation against Elecsys CA 72-4. Results: In the total precision study, the minimum coefficient of variation (CV) for Control/Panel samples over 4 U/mL was 1.1%. The measuring interval was from 0.95 to 200 U/mL with good linearity; and limits of blank (LoB), detection (LoD), and quantitation (LoQ) were 0.09, 0.18, and 0.95 U/mL, respectively. High dose hook effect; differences among specimen tube types; and interference of common drugs, potential cross-reactants, and endogenous substances were not observed. Significantly, this assay has high biotin tolerance at 4875 mg/mL and correlates well with the Elecys CA 72-4 assay (correlation coefficient: 0.95). Conclusions: ARCHITECT CA 72-4 is a highly sensitive and precise assay for CA 72-4 measurement in human sera and plasma.

3.
Electrophoresis ; 34(6): 825-32, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23307430

RESUMEN

Several method parameters have been refined for application of CIEF methods to provide optimal capillary robustness and performance longevity while maintaining desired analytical output for the ever increasing characterization scrutiny of protein reagents used in clinical assay formulations. Demonstrated here are significant modifications to the existing protocols in order to attain a robust, reproducible method that achieves as much as a 20-fold increase in the number of consecutive runs before capillary degradation. Not only is it a concern for the rudimentary analysis of acidic and basic components of the isoform profile for monoclonal antibodies, but a comprehensive identification of each individual isoform to obtain a characteristic fingerprint is necessary for minor distinguishable properties between multiple proteins in unambiguous identification. In order to maintain the integrity of these modifications, extensive studies were conducted on an implemented system suitability standard protein with specifically defined parameters indicating either sufficient or poor separation performance.


Asunto(s)
Anticuerpos Monoclonales/análisis , Focalización Isoeléctrica/métodos , Isoformas de Proteínas/análisis , Electroforesis Capilar/métodos , Pruebas Inmunológicas/métodos , Focalización Isoeléctrica/normas , Reproducibilidad de los Resultados
4.
Anal Biochem ; 415(2): 116-25, 2011 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-21549681

RESUMEN

Classic blotting methods remain a commonly applied approach to specific protein identification in gel electrophoresis of complex mixtures despite the inherent difficulty in band or spot matching due to significant variability of protein migration or localization in replicate blotting experiments. A direct application of both protein stain and protein blotting on a single membrane significantly reduces the complexity of the experiment and provides increased confidence of signal matching. Digital alignment of images acquired from both total protein stain and blotting development modes on a single membrane allows unambiguous spot or band assignments in these experiments as well as retention of quantitative information acquired from both modes of signal generation. A direct and simple method applying a fluorescent protein stain that is compatible with subsequent detection by antibody or lectin recognition factors along with common image adjustment software is examined. The utility of this blot dual-mode development method for direct protein recognition and quantification in one- and two-dimensional electrophoresis is demonstrated for bioanalytical objectives where replicate experiments are challenged by sample complexity.


Asunto(s)
Técnicas de Sonda Molecular , Proteínas/análisis , Anticuerpos/química , Western Blotting , Electroforesis en Gel Bidimensional/métodos , Electroforesis en Gel de Poliacrilamida/métodos , Humanos , Procesamiento de Imagen Asistido por Computador , Lectinas/química , Compuestos Organometálicos/química , Proteínas Recombinantes/análisis , Proteínas Recombinantes/metabolismo