1.
Phys Rev Lett ; 114(5): 054801, 2015 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-25699448

RESUMEN

The Linac Coherent Light Source has added a self-seeding capability to the soft x-ray range using a grating monochromator system. We report the demonstration of soft x-ray self-seeding with a measured resolving power of 2000-5000, wavelength stability of 10(-4), and an increase in peak brightness by a factor of 2-5 across the photon energy range of 500-1000 eV. By avoiding the need for a monochromator at the experimental station, the self-seeded beam can deliver as much as 50-fold higher brightness to users.

2.
Rofo ; 181(9): 851-8, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19517342

RESUMEN

PURPOSE: To compare the accuracy of frameless stereotactic and robot-assisted puncture in vitro based on computed tomography (CT) imaging with a slice thickness of 1, 3, and 5 mm. MATERIALS AND METHODS: 300 punctures were carried out with help of the Atlas aiming device guided by the optical navigation system Stealth Station TREONplus and 150 punctures were guided by the robotic assistance system Innomotion. Conically shaped rods were punctured with Kirschner wires. The accuracy was evaluated on the basis of control CTs by measuring the Euclidean distance between the wire tip and target and the normal distance between the target and wire. RESULTS: With the Stealth Station a mean Euclidean distance of 1.94 +/- 0.912, 2.2 +/- 1.136, and 2.74 +/- 1.166 mm at a slice thickness of 1, 3 and 5 mm, respectively, was reached. The mean normal distance was 1.64 +/- 0.919, 1.84 +/- 1.189, and 2.48 +/- 1.196 mm, respectively. The Innomotion system resulted in a mean Euclidean distance of 1.69 +/- 0.772, 1.91 +/- 0.673, and 2.30 +/- 0.881 mm, respectively, while the mean normal distance was 1.42 +/- 0.78), 1.60 +/- 0.733, and 1.98 +/- 1.002 mm, respectively. A statistical significance between accuracies with both systems with 1 mm and 3 mm slices could not be detected (p > 0.05). At a slice thickness of 5 mm, the robot was significantly more accurate, but not as accurate as when using thinner slices (p < 0.05). The procedure time is longer for the Innomotion system ( 30 vs. 18 min), and the practicability is higher with the Stealth Station. CONCLUSION: The systems yield comparable accuracy. A slice thickness of 3 mm is adequate. Application of both methods in patient treatment can be expected to be safe and reliable.


Asunto(s)
Biopsia con Aguja/instrumentación , Biopsia con Aguja/normas , Procesamiento de Imagen Asistido por Computador/instrumentación , Procesamiento de Imagen Asistido por Computador/normas , Imagenología Tridimensional/instrumentación , Imagenología Tridimensional/normas , Fantasmas de Imagen/normas , Radiografía Intervencional/instrumentación , Radiografía Intervencional/normas , Robótica/instrumentación , Robótica/normas , Cirugía Asistida por Computador/instrumentación , Cirugía Asistida por Computador/normas , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/normas , Adulto , Inteligencia Artificial , Niño , Diseño de Equipo , Estudios de Factibilidad , Humanos , Sistemas de Información Radiológica/normas , Estándares de Referencia , Sensibilidad y Especificidad , Estudios de Tiempo y Movimiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA