Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Shoulder Elbow Surg ; 30(5): 1174-1180, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-32890679

RESUMEN

HYPOTHESIS: The purpose of this study was to determine the prevalence and responsiveness of common patient-reported outcome (PRO) tools in patients undergoing primary total shoulder arthroplasty (TSA) for glenohumeral arthritis. METHODS: Using Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, a systematic review of anatomic and reverse TSA studies from PubMed, SportDiscus, Cochrane, and CINAHL was performed. Studies on primary TSA for glenohumeral arthritis that reported at least 1 PRO tool were included in the final analysis. A subgroup analysis of studies that reported preoperative and postoperative PRO scores with at least 2-year follow-up data was evaluated to compare the responsiveness between the different PRO instruments. RESULTS: After full-text review of 490 articles, 74 articles met all inclusion criteria and were included in the final analysis. Anatomic TSA was evaluated in 35 studies, reverse TSA in 32 studies, and both anatomic and reverse in 7 studies. There were a total of 7624 patients, and 25 different PRO tools were used. The most commonly reported PRO tools were the American Shoulder and Elbow Surgeons (44 studies), Constant (42 studies), the visual analog scale for pain (23 studies), and the Simple Shoulder Test (17 studies). A median of 3.0 PRO instruments were used in each study. All instruments had large effect sizes. The University of California at Los Angeles (UCLA) score was found to be the most responsive instrument, and the Single Assessment Numeric Evaluation score was least responsive. The American Shoulder and Elbow Surgeons score was the most responsive instrument that required only patient-reported data. CONCLUSION: Overall, the UCLA score was found to be the most responsive followed by the Adjusted Constant. However, both the UCLA and Adjusted Constant scores require strength and range of motion assessment that may limit their widespread clinical use. The increased responsiveness of these measures, which include objective clinical testing, speaks to the predicted increases in strength and range of motion after shoulder arthroplasty. Of the measures that can be administered without in-person clinical evaluation, the American Shoulder and Elbow Surgeons score and Western Ontario Osteoarthritis of the Shoulder index were the most responsive.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Osteoartritis , Articulación del Hombro , Humanos , Ontario , Osteoartritis/cirugía , Medición de Resultados Informados por el Paciente , Rango del Movimiento Articular , Estudios Retrospectivos , Articulación del Hombro/cirugía , Resultado del Tratamiento
2.
Clin Sports Med ; 37(2): 293-306, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29525029

RESUMEN

The rates of arthroscopic meniscus repair continue to increase with excellent reported outcomes. Complications, sometimes catastrophic, following meniscus repair may occur. The rate of postoperative complications may be reduced by adequate diagnosis, appropriate patient selection, meniscus repair selection, surgical techniques, and postoperative management. When complications occur, the provider must identify and take steps to rectify as well as prevent further complications from occurring. The purpose of this article is to detail the common diagnostic, technical, and postoperative pitfalls that may result in poor patient outcomes.


Asunto(s)
Artroscopía/efectos adversos , Traumatismos de la Rodilla/cirugía , Complicaciones Posoperatorias , Lesiones de Menisco Tibial/cirugía , Artroscopía/métodos , Humanos , Traumatismos de la Rodilla/diagnóstico por imagen , Complicaciones Posoperatorias/prevención & control , Complicaciones Posoperatorias/terapia , Lesiones de Menisco Tibial/diagnóstico por imagen , Resultado del Tratamiento
3.
Sports Med Arthrosc Rev ; 25(4): 219-226, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29095401

RESUMEN

There has been an increasing awareness of the importance of the meniscus in maintaining the health and function of the knee. When injured, magnetic resonance imaging (MRI) has become the gold standard to diagnose meniscal tears. The information obtained from the MRI helps determine the need for surgical intervention. To achieve the best patient outcome a surgeon must be able to diagnose a meniscal injury by MRI as well as identify the injury at time of arthroscopy. This article aims to illustrate meniscal pathology utilizing side by side comparison of MRI identified meniscal injuries to its arthroscopic correlate as well as describe treatment options for the injury.


Asunto(s)
Artroscopía , Imagen por Resonancia Magnética , Lesiones de Menisco Tibial/diagnóstico por imagen , Humanos , Meniscos Tibiales/diagnóstico por imagen
4.
Orthopedics ; 40(6): e1050-e1054, 2017 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-28968475

RESUMEN

Neer type II distal clavicle fractures are inherently unstable. The purpose of this study was to review the outcome of Neer type II distal clavicle fractures arthroscopically treated using a suspensory cortical button technique. Between 2008 and 2012, a total of 17 Neer type IIB fractures were managed operatively at the authors' institution. Functional outcomes were assessed using the pain score, the Disabilities of the Arm, Shoulder and Hand score, the Penn Shoulder Score, and the American Shoulder and Elbow Surgeons score. Radiographic union was also assessed. At a mean of 1 year, the mean pain score was 0.9±1.1, the mean Disabilities of the Arm, Shoulder and Hand score was 10.9±11.1, the mean Penn Shoulder Score was 90.3±7.9, and the mean American Shoulder and Elbow Surgeons score was 90.1±10.1. Radiographic union occurred in 14 patients. An all-arthroscopic surgical fixation of Neer type II distal clavicle fractures using a suspensory cortical button technique can result in a predictable outcome with a low complication rate. [Orthopedics. 2017; 40(6):e1050-e1054.].


Asunto(s)
Artroscopía/métodos , Clavícula/lesiones , Fijación Interna de Fracturas/métodos , Fracturas Óseas/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Artroscopía/instrumentación , Clavícula/cirugía , Femenino , Estudios de Seguimiento , Fijación Interna de Fracturas/instrumentación , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
5.
Orthopedics ; 36(1): e117-20, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23276343

RESUMEN

Injury to the distal triceps tendon is uncommon and can be difficult to diagnose, especially when a partial rupture or tear occurs. In situations where an incomplete disruption to the musculotendinous unit occurs, a palpable defect or clear functional loss may not be present. Advanced imaging techniques, such as magnetic resonance imaging or ultrasound, can be used to confirm the diagnosis and define the extent of injury. The treatment of a complete rupture of the distal triceps tendon is repair or reconstruction, whereas the management of a patient with a partial triceps rupture is related to the pain, functional deficit, and expectations of the patient. This article presents 2 patients with chronic, near complete disruptions of the distal triceps tendon. In both patients, surgical reconstruction of the injured tendon was accomplished using ipsilateral palmaris longus autograft. This technique allows the treating surgeon to harvest the graft from the ipsilateral upper extremity. The palmaris autograft is then used to reconstruct the injured portion of the triceps tendon using a Pulvertaft weave technique through the intact triceps tendon and osseous tunnels within the proximal ulna. This technique allows for easy surgical setup and harvest of autograft tendon and provides a structurally sound technique for a tension-free reconstruction of the injured tendon. It also permits early postoperative elbow range of motion, with active elbow extension allowed at 6 weeks. The authors have used this technique successfully in the treatment of chronic partial tears of the distal triceps tendon.


Asunto(s)
Traumatismos del Brazo/cirugía , Traumatismos de los Tendones/cirugía , Tendones/trasplante , Adulto , Humanos , Masculino , Persona de Mediana Edad , Procedimientos de Cirugía Plástica , Trasplante Autólogo
6.
Foot Ankle Int ; 32(4): 432-6, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21733448

RESUMEN

BACKGROUND: This study evaluated the effects of locking vs nonlocking configuration on the biomechanical performance of a calcaneal reconstruction plate in an osteoporotic cadaveric model. MATERIALS AND METHODS: A Saunders II B type calcaneal fracture was created in ten matched pair of cadaveric calcanei. Each pair was fixed with the Ascension calcaneal reconstruction plate using either locking or nonlocking screws in the same hole pattern. Specimens were axially loaded for 1000 cycles through the talus followed by load to failure. Statistical comparisons were made between the locking and nonlocking constructs on the displacements during cyclic loading as well as construct stiffness and load achieved at selected fragment displacements. RESULTS: No significant difference was detected between the locking and nonlocking constructs in displacement during cyclic loading (p > 0.2) for the numbers available. Similarly no significant difference was found in stiffness of the constructs between the groups: 445.7 ± 148.8 (N/mm ± SD) for the locking plate and 395.2 ± 127.7 for the nonlocking plate (p > 0.14). The load achieved at 2 mm displacement of the posterior fragment for the two groups were not different: locking plate at 744.6 ± 237.2 N and nonlocking plate at 739.3 ± 269.7 N (p > 0.99). CONCLUSION: This study did not reveal a mechanical advantage to locking technology for calcaneal fractures with the selected plate and fracture model. CLINICAL RELEVANCE: While locking plate technology has shown mechanical advantages for fracture management in other osteoporotic models, in our fracture model and plating construct, this was not found. It is still unclear which fixation technique is most beneficial in these calcaneal fractures.


Asunto(s)
Placas Óseas , Tornillos Óseos , Calcáneo/lesiones , Fijación Interna de Fracturas/métodos , Fracturas Óseas/cirugía , Fracturas Osteoporóticas/cirugía , Procedimientos de Cirugía Plástica/métodos , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Calcáneo/fisiopatología , Calcáneo/cirugía , Humanos , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA