The aim of this study was to compare neointima proliferation in three drug-eluting stents (DES) produced by the same company (Balton, Poland) which are covered with a biodegradable polymer and elute sirolimus (concentration: 1.0 and 1.2 µg/mm2), but have different stent platforms and strut thickness: stainless steel Prolim® (115 µm) and BiOSS LIM® (120 µm) and cobalt-chromium Alex® (70 µm). We analyzed data of patients with quantitative coronary angiography (QCA) and optical coherence tomography (OCT) at 12 months from BiOSS LIM Registry, Prolim Registry and Alex OCT clinical trial. There were 56 patients enrolled, in whom 29 Prolim® stents were deployed, in 11-BiOSS LIM® and in 16-Alex stents. The late lumen loss was the smallest in Prolim® subgroup (0.26 ± 0.17 mm) and did not differ from Alex® subgroup (0.28 ± 0.47 mm). This parameter was significantly bigger in BiOSS® subgroup (0.38 ± 0.19 mm; p < 0.05). In OCT analysis there was no statistically significant difference between Prolim® and Alex® subgroups in terms of mean neointima burden (24.6 ± 8.6 vs. 19.27 ± 8.11%) and neointima volume (28.16 ± 15.10 vs. 24.51 ± 17.64 mm3). In BiOSS® group mean neointima burden (30.9 ± 6.2%) and mean neointima volume (44.9 ± 4.9 mm3) were significantly larger. The morphological analysis revealed that in most cases in all groups the neointima was homogenous with plaque presence only around stent struts. In the QCA and OCT analysis regular DES (Prolim® and Alex®) obtained similar results, whereas more pronounced response from the vessel wall was found in the BiOSS® subgroup.
Asunto(s)
Neointima , Stents , Stents Liberadores de FármacosRESUMEN
The aim of this study was to analyze the difference in neointima pattern assessed by intravascular ultrasound (IVUS) between two dedicated bifurcation stents, BiOSS® Expert and BiOSS® LIM at 12-month follow-up. This manuscript reports IVUS findings obtained from the analysis of patients enrolled into first-in-man registries initially assessing the BiOSS Expert® (paclitaxel) and BiOSS LIM® (sirolimus) stents. Quantitative angiographic analysis was performed pre, post-stenting, and at follow-up. IVUS examination was performed at 12 months. There were analyzed 34 cases (BiOSS Expert® 11 patients, BiOSS LIM® 23 patients). Procedural characteristics in the two groups were similar, except for rates of main vessel predilatation and FKB/POT, which were higher in BiOSS® LIM group, 54.5 % vs 73.9 % (P < 0.05) and 0 % vs 39.1 % (P < 0.05), respectively. When comparing late lumen loss (LLL) for both stents there were significantly bigger values for main vessel and main branch in the BiOSS® Expert group, but not in side branch. Intravascular ultrasound examination showed that in the BiOSS LIM® group comparing with the BiOSS Expert® group there was lower neointima burden in the whole stent (24.7 ± 7.5 % vs 19.4 ± 8.6 %, P < 0.05) as well as in main vessel (22.8 ± 5.6 % vs 16.9 ± 6.1 %, P < 0.05) and main branch (36.1 ± 6.5 % vs 27.6 ± 8.7 %, P < 0.05), but not at the level of bifurcation (15.1 ± 3.8 % vs 13.6 ± 5.4 %, P = NS). In addition, we found that final kissing balloon/proximal optimization technique (FKB/POT) was associated with significantly smaller value of LLL in main vessel (0.24 ± 0.09 mm vs 0.32 ± 0.14 mm, P < 0.05), which in IVUS analysis resulted in smaller neointima burden in main vessel (13.7 ± 3.9 % vs 18.9 ± 4.45 %, P < 0.05) as well as at the bifurcation site (12.6 ± 4.1 % vs 14.1 ± 2.4 %, P < 0.05)...