Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Saudi J Anaesth ; 12(3): 433-439, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30100843

RESUMEN

OBJECTIVES: The aim of the study was to compare time to intubation and glottic visualization between Macintosh, McCoy, and Glidescope video laryngoscope (GVL) in morbidly obese patients. METHODOLOGY: Forty-five American Society of Anesthesiologists I-III morbidly obese patients were randomized into three groups of 15 each and time to intubation, Cormack-Lehane grading, and Intubation Difficulty Score (IDS) were compared. RESULTS: GVL took more time to intubate (TTI) compared to Macintosh and McCoy laryngoscope (P = 0.0001). Overall IDS were similar between the groups. CONCLUSION: To conclude, GVL takes longer TTI with no added advantage in IDS and hemodynamic response to intubation in morbidly obese patients. McCoy is only as effective as Macintosh and hence Macintosh laryngoscope should be laryngoscope of choice due to its widespread availability and familiarity.

2.
Indian J Anaesth ; 62(4): 303-309, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29720757

RESUMEN

BACKGROUND AND AIMS: Increasing the cross-sectional area (CSA) of the internal jugular vein (IJV) improves the success rate of cannulation and decreases complications. Application of positive end-expiratory pressure (PEEP) may increase the CSA of IJV beyond that achieved in Trendelenburg position. However, the optimum PEEP to achieve maximal increase in CSA of IJV and the effect of PEEP on IJV and CA relationship is not known. METHODS: In this prospective, blinded, randomised controlled study, 120 anesthetised paralysed patients of the American Society of Anesthesiologists physical Status I-II were placed in 20° Trendelenburg position. Patients were randomised into four groups as follows: PEEP of 0, 5, 10 and 15 cmH2O. CSA, anteroposterior (AP) diameter and transverse diameter (Td) of IJV and overlapping of IJV with CA were assessed using two-dimensional ultrasound. Statistical analysis was performed in SPSS version 21.0 software using Chi-square/Fisher's exact test (categorical data) and analysis of variance (continuous data) tests and P < 0.05 was considered statistically significant. RESULTS: There was significant increase in AP diameter, CSA and Td with the application of PEEP 10-15 cmH2O. Increase in CSA up to 25% with PEEP 10 and 44% with PEEP 15 was noted. There was a significant decrease in the overlapping of the internal CA with an increase in PEEP. It ranged from 21% at P0 to 17% P15. CONCLUSION: Application of PEEP 10-15 cmH2O in Trendelenburg position significantly increased CSA and AP diameter of IJV and decreased CA overlap of IJV in anesthetised paralysed patients.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA