Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Macromol Rapid Commun ; 39(2)2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29094443

RESUMEN

The development of coupled techniques based on chemically sensitive detectors, such as FTIR or NMR spectrometers, for size exclusion chromatography (SEC) provides sophisticated methods for determining the molecular-weight-dependent chemical composition in polymers. However, the detection of rare functionalities such as end groups or branching points presents a challenge, especially for online coupled SEC detection, which is based on low-concentration chromatography. To address this issue, for the first time, an external cavity quantum cascade laser (EC-QCL) infrared spectrometer is coupled to an SEC. The system is evaluated using polystyrene/poly(methyl methacrylate) (PS/PMMA) blends. The current limit of detection for the carbonyl (PMMA) stretch vibration at 1730 cm-1 with this technique is 3.5 µg PMMA on a semipreparative column (typical load of 2.5 mg polymer in total). That equals 0.15 mol% of PMMA in the PS/PMMA blend and corresponds to one carbonyl group per 70 kg mol-1 polymer.


Asunto(s)
Internet , Rayos Láser , Teoría Cuántica , Cromatografía en Gel , Espectroscopía de Resonancia Magnética , Polimetil Metacrilato/química , Poliestirenos/química , Espectroscopía Infrarroja por Transformada de Fourier
2.
Analyst ; 139(9): 2057-64, 2014 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-24611154

RESUMEN

This work introduces a tunable mid-infrared (mid-IR) external cavity quantum cascade laser (EC-QCL) as a new molecular specific detector in liquid chromatography. An EC-QCL with a maximum tunability of 200 cm(-1) (1030-1230 cm(-1)) was coupled to isocratic high performance liquid chromatography (HPLC) for the separation of sugars with a cation exchange column (counter ion: Ca(2+)) and distilled water as the mobile phase. Transmission measurements in a 165 µm thick flow cell allowed for on-line coupling and independent quantification of glucose, fructose and sucrose in the concentration range from 5 mg mL(-1) to 100 mg mL(-1) in several beverages. The results obtained with the EC-QCL detector were found to be in good agreement with those obtained using a differential refractive index detector as a reference. The standard deviation of the method for the linear calibration was better than 5 mg mL(-1) for all sugars and reached a minimum of 1.9 mg mL(-1), while the DRI detector reached a minimum of 1 mg mL(-1). Besides the quantification of sugars for which a calibration was performed, also chromatographic peaks of other components could be identified on the basis of their IR absorption spectra. This includes taurine, ethanol, and sorbitol.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Cromatografía por Intercambio Iónico/métodos , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Bebidas/análisis , Calibración , Estándares de Referencia , Espectroscopía Infrarroja por Transformada de Fourier/instrumentación
3.
Macromol Rapid Commun ; 33(20): 1747-52, 2012 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-22893317

RESUMEN

The determination of molecular weight and correlated chemical composition is of major interest for the advanced analysis of copolymers, blends, or unknown samples. In this work, we present a new way of online coupling IR spectroscopy and SEC to achieve a chemically sensitive, universally applicable SEC detector. Our method overcomes the limitations of existing spectroscopy-SEC combinations. We solved the major problems, like huge intensity of solvent signals (polymer concentration in detector <1 g L(-1) ) and short measuring time (<30 s), by recording the IR spectra with fully optimized sensitivity and by following mathematical solvent suppression. The measuring time for a certain S/N was reduced in several optimization steps by a factor of more than 70 000. The resulting sensitivity allows online coupled IR-SEC measurements.


Asunto(s)
Polímeros/química , Absorción , Dióxido de Carbono/química , Cromatografía en Gel , Peso Molecular , Solventes/química , Espectroscopía Infrarroja por Transformada de Fourier , Agua/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA