Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Water Res ; 256: 121647, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38657311

RESUMEN

Retention of microplastics (MPs) at the third largest wastewater treatment plant (WWTP) in Sweden was investigated. The plant is one of the most modern and advanced of its kind, with rapid sand filter for tertiary treatment in combination with mechanical, biological, and chemical treatment. It achieved a significantly high treatment efficiency, which brought the MP concentration in its discharge on par with concentrations measured in marine waters of the same region. This novel data shows that properly designed modern WWTPs can reduce the MP content of sewage down to background levels measured in the receiving aquatic environment. Opposite to current understanding of the retention of MP by WWTPs, a modern and well-designed WWTP does not have to be a significant point source for MP. MPs were quantified at all major treatment steps, including digester inlet and outlet sludge. MPs sized 10-500 µm were analyzed by a focal plane array based micro-Fourier transform infrared (FPA-µFTIR) microscopy, a hyperspectral imaging technique, while MPs above 500 µm were analyzed by Attenuated Total Reflectance-Fourier transform infrared (ATR-FTIR) spectroscopy. Mass was estimated from the hyperspectral images for MPs <500 µm and from microscope images >500 µm. The overall treatment efficiency was in terms of MP counts 99.98 %, with a daily input of 6.42 × 1010 and output of 1.04 × 107 particles. The mass removal efficiency was 99.99 %. The mechanical part of the treatment, the pre-treatment, and primary stages, reduced both the MP counts and mass by approximately 71 %. The combined biological treatment, secondary settling, and final polishing with rapid sand filtration removed nearly all the remaining 29 %. MPs became successively smaller as they passed the different treatment steps. The digester inlet received 1.04 × 1011 MPs daily, while it discharged 9.96 × 1010 MPs, causing a small but not significant decrease in MP counts, with a corresponding MP mass reduction of 9.56 %.


Asunto(s)
Microplásticos , Agua de Mar , Eliminación de Residuos Líquidos , Aguas Residuales , Contaminantes Químicos del Agua , Microplásticos/análisis , Aguas Residuales/química , Eliminación de Residuos Líquidos/métodos , Contaminantes Químicos del Agua/análisis , Agua de Mar/química , Suecia , Espectroscopía Infrarroja por Transformada de Fourier , Aguas del Alcantarillado/química , Purificación del Agua/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA