Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Am Coll Cardiol ; 30(4): 1032-8, 1997 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-9316535

RESUMEN

BACKGROUND: Intraatrial reentrant tachycardia (IART) is a common problem in patients with congenital heart disease (CHD). The progression of clinical symptoms of IART and their response to radiofrequency (RF) ablation are not yet well described. OBJECTIVES: The objective of the study was to determine the early and midterm success rates of RF ablation in effecting a reduction of clinical arrhythmic events in patients with IART and CHD. METHODS: Clinical records of patients undergoing early, successful RF ablation were analyzed retrospectively to document the occurrence and frequency of documented IART, cardioversion and arrhythmia-related hospital visits before and after ablation. RESULTS: Fifty-five catheterizations for intended RF ablation of IART were performed in 45 patients (mean [+/-SD] age 24.5 +/- 10.5 years, 40 after surgical palliation of CHD). Early success was achieved for one or more IART circuits in 33 patients (73%). Mean clinical follow-up of those patients with successful ablation is 17.4 +/- 11.3 months (total 574 patient-months). Documented IART recurrence was noted after 21 (53%) of 40 early, successful catheterizations in 17 (52%) of 33 patients, with a mean time to recurrence of 4.1 months, often with electrocardiographically novel configurations. A more prolonged and frequent history of IART was a univariate risk factor for recurrence. Seven patients underwent repeat RF ablations, and eight patients were restarted on antiarrhythmic medications after ablation. Two patients who had severe ventricular dysfunction before RF ablation died 1.5 and 11 months after RF ablation without known arrhythmia recurrence. Clinical events related to IART increased steadily in frequency for 24 months before RF ablation. Radiofrequency ablation resulted in a reduction of event frequency to levels significantly lower than those in the 12-month period before RF ablation and not significantly different from those levels observed at baseline 3 to 4 years before RF ablation. CONCLUSIONS: In patients with successful RF ablation, the frequency of subsequent events was reduced compared with the 2 preceding years. However, recurrence of IART in patients who showed clinical improvement was frequent, and often revealed the presence of new IART configurations.


Asunto(s)
Ablación por Catéter , Cardiopatías Congénitas/complicaciones , Taquicardia por Reentrada en el Nodo Atrioventricular/etiología , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Adolescente , Adulto , Análisis de Varianza , Niño , Cardioversión Eléctrica , Electrocardiografía , Hospitalización , Humanos , Incidencia , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
2.
J Pediatr ; 131(6): 878-87, 1997 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-9427894

RESUMEN

OBJECTIVE: A review of the results of the first 5 years of radiofrequency catheter ablation procedures performed at Children's Hospital, Boston, a large tertiary referral center for patients with congenital heart disease and arrhythmias common to the infant, child, and young adult. STUDY DESIGN: A retrospective review of 410 consecutive procedures in 346 patients who underwent at least one application of radiofrequency energy for the treatment of recurrent supraventricular or ventricular tachycardia. RESULTS: The overall final success rate for all diagnoses was 90%, with a higher success rate in patients with an accessory pathway (96%). During the 5-year study period, the success rate improved while the rates of failures and late recurrences declined. The incidence of serious complications was 1.2% (1 late death, 1 ventricular dysfunction, 1 complete heart block, 1 cardiac perforation, and 1 cerebrovascular accident). CONCLUSIONS: This report of a large series of radiofrequency catheter ablation procedures performed at an institution committed to treating congenital heart disease and pediatric arrhythmias confirms the safety and efficacy of this procedure. The pediatric cardiologist/electrophysiologist treating such patients must be aware of specific technical, anatomic, and electrophysiologic variations in the pediatric patient that are critical to the success of this therapy.


Asunto(s)
Arritmias Cardíacas/cirugía , Ablación por Catéter/métodos , Cardiopatías Congénitas/cirugía , Terapia por Radiofrecuencia , Adolescente , Adulto , Arritmias Cardíacas/etiología , Ablación por Catéter/efectos adversos , Distribución de Chi-Cuadrado , Niño , Preescolar , Femenino , Estudios de Seguimiento , Cardiopatías Congénitas/complicaciones , Cardiopatías/complicaciones , Cardiopatías/diagnóstico , Cardiopatías/cirugía , Humanos , Lactante , Recién Nacido , Masculino , Persona de Mediana Edad , Recurrencia , Estudios Retrospectivos , Taquicardia/clasificación , Taquicardia/etiología , Taquicardia/cirugía , Síndrome de Wolff-Parkinson-White/etiología , Síndrome de Wolff-Parkinson-White/cirugía
3.
J Appl Physiol (1985) ; 75(4): 1439-43, 1993 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-8282587

RESUMEN

To study the effects of airway obstruction (AWO) and arousal on coronary blood flow, mean arterial pressure (MAP), and heart rate, pigs were chronically instrumented with arterial catheters, Doppler flow probes on the left circumflex coronary artery, and electrodes for determination of sleep stages. A modified tracheostomy tube was placed in the trachea to obstruct the upper airway during sleep sessions. In control studies, during non-rapid-eye-movement (NREM) sleep, MAP was 84 +/- 2 mmHg before AWO and increased by 5 +/- 2 mmHg on arousal. MAP was lower during rapid-eye-movement (REM) sleep (62 +/- 2 mmHg), and the increase on arousal was fourfold greater (22 +/- 2 mmHg). Heart rate was similar in both sleep stages (NREM: 120 +/- 4 beats/min; REM: 124 +/- 5 beats/min) and increased significantly on arousal (NREM: 12 +/- 2 beats/min; REM: 18 +/- 1 beats/min). Coronary blood flow was similar during both stages (NREM: 43 +/- 4 ml/min; REM: 46 +/- 8 ml/min) and increased by 12-15% on arousal. Coronary vascular resistance index increased significantly by 24% on arousal from AWO during REM sleep. All increases and decreases were significant at P < 0.05. Receptor blockade studies were performed to assess alpha-adrenergic receptor involvement.


Asunto(s)
Nivel de Alerta/fisiología , Hemodinámica/fisiología , Síndromes de la Apnea del Sueño/fisiopatología , Obstrucción de las Vías Aéreas/fisiopatología , Animales , Presión Sanguínea/fisiología , Circulación Coronaria/fisiología , Modelos Animales de Enfermedad , Electrodos , Masculino , Fentolamina/farmacología , Polisomnografía , Sueño REM/fisiología , Porcinos , Tráquea/fisiología , Resistencia Vascular/fisiología
4.
J Am Coll Cardiol ; 22(4): 1105-10, 1993 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-8409048

RESUMEN

OBJECTIVES: Using a new mapping system that allows the simultaneous acquisition of data from 25 right atrial bipolar electrodes during cardiac catheterization, we mapped normal sinus rhythm and atrial reentrant tachycardia in 24 sheep (20 to 49 kg) and 7 pigs (25 to 35 kg). BACKGROUND: Rapid, high resolution mapping during cardiac catheterization may shorten ablation procedures and permit ablation of otherwise refractory arrhythmias. METHODS: A flexible, elliptic, basket-shaped recording catheter has five spokes, each with 10 electrodes arranged as 5 bipolar pairs. Catheter shape, electrode spacing and introduction technique were modified in response to the results of experiments in the first 23 animals. In the most recent eight animals, retraction of a string attached to the distal tip distended the basket, providing safe tissue contact. Filtered (30 to 250 Hz) bipolar recordings from all 25 electrode pairs, as well as a surface electrocardiogram, were recorded and digitized at 1,000 Hz using custom software. An activation map was digitally constructed and superimposed on anteroposterior and lateral fluoroscopic catheter images. Bipolar recordings were made in normal sinus rhythm (31 animals), with adequate signals recorded from > 95% of electrode pairs. Rapid burst pacing and intentional right atrial air embolus (30 to 50 ml) induced sustained atrial reentrant tachycardia in five animals, which was also adequately recorded. RESULTS: Catheter positioning and complete atrial mapping required < 10 min after venous access in the most recent eight experiments. The catheter was left in position for up to 4 h. Postmortem evaluation revealed minor superficial abrasion of the venae cavae or right atrial endocardium in six animals and moderate abrasion in two. No other damage was observed. CONCLUSIONS: This new system may ultimately assist in mapping simple or complex atrial arrhythmias during cardiac catheterization.


Asunto(s)
Cateterismo Cardíaco/métodos , Ablación por Catéter/métodos , Electrocardiografía/métodos , Procesamiento de Señales Asistido por Computador , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Animales , Cateterismo Cardíaco/instrumentación , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Modelos Animales de Enfermedad , Electrocardiografía/instrumentación , Electrodos , Diseño de Equipo , Estudios de Evaluación como Asunto , Atrios Cardíacos , Radiografía , Ovinos , Porcinos , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico por imagen , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA