Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Clin Lab Anal ; 36(9): e24610, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35852988

RESUMEN

BACKGROUND: Vitamin D deficiency/insufficiency and toxicity are worldwide issues; thus, accurate diagnostic assays are required to measure vitamin D. We evaluated the performance of the new Elecsys® Vitamin D total III assay (Roche Diagnostics International Ltd). METHODS: Repeatability and intermediate precision of the Elecsys Vitamin D total III assay (cobas e 601 analyzer) were evaluated at three sites using five human serum pools (HSPs) and two PreciControls (five-day model, one reagent lot [CLSI-EP05-A3]) and compared against prespecified acceptance criteria. A serum verification panel, with reference isotope dilution liquid chromatography tandem mass spectrometry (ID-LC-MS/MS) values, was used for comparator assay/concordance studies at two sites, assessed using unweighted Deming regression. Testing of serum vs. plasma on the Elecsys assay was conducted at one site using samples from healthy adults; assessed using Passing-Bablok regression. RESULTS: Repeatability (HSP1 [16.8-18.4 ng/ml], SD 0.87-1.07; HSP5 [94.5-98.0 ng/ml], CV 1.58%-2.76%) and intermediate precision (HSP1, SD 1.14-1.77; HSP5, CV 2.00%-4.13%) met acceptance criteria across sites. Agreement was observed between the Elecsys assay and (i) the ID-LC-MS/MS verification panel (slope, 0.936-1.01; Pearson's r, 0.960-0.986) and (ii) comparator assays (slope, 0.921-1.15; Pearson's r, 0.958-0.982). The Elecsys assay correctly assigned the highest combined percentage of samples to deficient (100%) and insufficient (89.5%) vitamin D categories vs. comparator assays and demonstrated comparable performance in serum and plasma (y = 0.103 + 0.984x). CONCLUSIONS: The Elecsys Vitamin D total III assay demonstrated good analytical performance and compared favorably with other assays, supporting its use in clinical practice.


Asunto(s)
Espectrometría de Masas en Tándem , Vitamina D , Adulto , Cromatografía Liquida/métodos , Humanos , Inmunoensayo/métodos , Isótopos , Espectrometría de Masas en Tándem/métodos , Vitaminas
2.
J Appl Lab Med ; 7(2): 503-514, 2022 03 02.
Artículo en Inglés | MEDLINE | ID: mdl-34662384

RESUMEN

BACKGROUND: Androstenedione (ASD) levels can aid diagnosis of hyperandrogenism together with other clinical/laboratory findings. We evaluated performance of the new, automated Elecsys® ASD assay vs an ASD isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) reference measurement procedure and determined reference ranges. METHODS: Repeatability/intermediate precision were assessed using 3 control levels and 5 human serum pools (n = 75 each; Clinical and Laboratory Standards Institute EP05-A3). Method comparisons vs commercially available immunoassays [IMMULITE ASD (Siemens) and LIAISON ASD (DiaSorin)] and an ID-LC-MS/MS measurement procedure method were conducted using 421 serum samples; Passing-Bablok regression and Pearson's correlation coefficients were calculated. Reference ranges and distribution of values associated with polycystic ovary syndrome (PCOS) were determined in five clinical cohorts using samples from several sites/vendors. RESULTS: Repeatability/intermediate precision coefficients of variation across all sites were 2.01% to 3.91% and 2.43% to 4.30%, respectively (mean ASD: 7.80-34.7 nmol/L). The Elecsys ASD assay showed poor agreement with IMMULITE ASD (slope = 0.459; r = 0.856; n = 320), fair agreement with LIAISON ASD (slope = 0.625; r = 0.984; n = 327), and very good agreement with ID-LC-MS/MS (slope = 1.040; r = 0.996; n = 332). Reference ranges (2.5th-97.5th percentiles) were: children (≤8 years; n = 140), <0.525 to 1.81 nmol/L; males (≥18 years; n = 138), 0.979 to 5.32 nmol/L; and postmenopausal females (n = 140), 0.654 to 3.74 nmol/L. Reference range (5th-95th percentiles) for females with fertile cycle (≥18 years; n = 84) was 1.71 to 4.58 nmol/L. The distribution of values (2.5th-97.5th percentiles) in females with PCOS (n = 125) was 2.26 to 12.1 nmol/L. CONCLUSIONS: Elecsys ASD assay demonstrated excellent precision and very good agreement with ID-LC-MS/MS. Reference ranges were established to support results interpretation in routine practice.


Asunto(s)
Androstenodiona , Síndrome del Ovario Poliquístico , Niño , Cromatografía Liquida/métodos , Femenino , Humanos , Inmunoensayo/métodos , Masculino , Valores de Referencia , Espectrometría de Masas en Tándem/métodos
3.
Heart ; 105(20): 1559-1567, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31142594

RESUMEN

OBJECTIVE: Patients with suspected acute myocardial infarction (AMI) in the setting of left bundle branch block (LBBB) present an important diagnostic and therapeutic challenge to the clinician. METHODS: We prospectively evaluated the incidence of AMI and diagnostic performance of specific ECG and high-sensitivity cardiac troponin (hs-cTn) criteria in patients presenting with chest discomfort to 26 emergency departments in three international, prospective, diagnostic studies. The final diagnosis of AMI was centrally adjudicated by two independent cardiologists according to the universal definition of myocardial infarction. RESULTS: Among 8830 patients, LBBB was present in 247 (2.8%). AMI was the final diagnosis in 30% of patients with LBBB, with similar incidence in those with known LBBB versus those with presumably new LBBB (29% vs 35%, p=0.42). ECG criteria had low sensitivity (1%-12%) but high specificity (95%-100%) for AMI. The diagnostic accuracy as quantified by the receiver operating characteristics (ROC) curve of hs-cTnT and hs-cTnI concentrations at presentation (area under the ROC curve (AUC) 0.91, 95% CI 0.85 to 0.96 and AUC 0.89, 95% CI 0.83 to 0.95), as well as that of their 0/1-hour and 0/2-hour changes, was very high. A diagnostic algorithm combining ECG criteria with hs-cTnT/I concentrations and their absolute changes at 1 hour or 2 hours derived in cohort 1 (45 of 45(100%) patients with AMI correctly identified) showed high efficacy and accuracy when externally validated in cohorts 2 and 3 (28 of 29 patients, 97%). CONCLUSION: Most patients presenting with suspected AMI and LBBB will be found to have diagnoses other than AMI. Combining ECG criteria with hs-cTnT/I testing at 0/1 hour or 0/2 hours allows early and accurate diagnosis of AMI in LBBB. TRIAL REGISTRATION NUMBER: APACE: NCT00470587; ADAPT: ACTRN12611001069943; TRAPID-AMI: RD001107;Results.


Asunto(s)
Algoritmos , Bloqueo de Rama , Errores Diagnósticos/prevención & control , Electrocardiografía/métodos , Infarto del Miocardio , Troponina I/análisis , Área Bajo la Curva , Biomarcadores/análisis , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/epidemiología , Reglas de Decisión Clínica , Servicio de Urgencia en Hospital/estadística & datos numéricos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/sangre , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/epidemiología , Infarto del Miocardio/terapia , Estudios Prospectivos , Tiempo de Tratamiento
4.
Crit Pathw Cardiol ; 18(1): 10-15, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30747759

RESUMEN

The TRAPID-AMI (High Sensitivity Cardiac Troponin T assay for rapid Rule-out of Acute Myocardial Infarction) study evaluated a rapid "rule-out" acute myocardial infarction (AMI). We evaluated what symptoms were associated with AMI as part of a substudy of TRAPID-AMI. There were 1282 patients evaluated from 12 centers in Europe, the United States of America, and Australia from 2011 to 2013. Multiple symptom variables were prospectively obtained and evaluated for association with the final diagnosis of AMI. Multivariate logistic regression analysis was done, and odds ratios (OR) were calculated. There were 213/1282 (17%) AMIs. Four independent predictors for the diagnosis of AMI were identified: radiation to right arm or shoulder [OR = 3.0; confidence interval (CI): 1.8-5.0], chest pressure (OR = 2.5; CI: 1.3-4.6), worsened by physical activity (OR = 1.7; CI: 1.2-2.5), and radiation to left arm or shoulder (OR = 1.7; CI: 1.1-2.4). In the entire group, 131 (10%) had radiation to right arm or shoulder, 897 (70%) had chest pressure, 385 (30%) worsened with physical activity, and 448 (35%) had radiation to left arm or shoulder. Duration of symptoms was not predictive of AMI. There were no symptoms predictive of non-AMI. Relationship between AMI size and symptoms was also studied. For 213 AMI patients, cardiac troponins I values were divided into 4 quartiles. Symptoms including pulling chest pain, supramammillary right location, and right arm/shoulder radiation were significantly more likely to occur in patients with larger AMIs. In a large multicenter trial, only 4 symptoms were associated with the diagnosis of AMI, and no symptoms that were associated with a non-AMI diagnosis.


Asunto(s)
Infarto del Miocardio/diagnóstico , Troponina/sangre , Anciano , Biomarcadores/sangre , Diagnóstico Diferencial , Electrocardiografía , Servicio de Urgencia en Hospital , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/sangre , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Tiempo
5.
Artículo en Inglés | MEDLINE | ID: mdl-28167641

RESUMEN

BACKGROUND: The TRAPID-AMI trial study (High-Sensitivity Troponin-T Assay for Rapid Rule-Out of Acute Myocardial Infarction) evaluated high-sensitivity cardiac troponin-T (hs-cTnT) in a 1-hour acute myocardial infarction (AMI) exclusion algorithm. Our study objective was to evaluate the prognostic utility of a modified HEART score (m-HS) within this trial. METHODS AND RESULTS: Twelve centers evaluated 1282 patients in the emergency department for possible AMI from 2011 to 2013. Measurements of hs-cTnT (99th percentile, 14 ng/L) were performed at 0, 1, 2, and 4 to 14 hours. Evaluation for major adverse cardiac events (MACEs) occurred at 30 days (death or AMI). Low-risk patients had an m-HS≤3 and had either hs-cTnT<14 ng/L over serial testing or had AMI excluded by the 1-hour protocol. By the 1-hour protocol, 777 (60%) patients had an AMI excluded. Of those 777 patients, 515 (66.3%) patients had an m-HS≤3, with 1 (0.2%) patient having a MACE, and 262 (33.7%) patients had an m-HS≥4, with 6 (2.3%) patients having MACEs (P=0.007). Over 4 to 14 hours, 661 patients had a hs-cTnT<14 ng/L. Of those 661 patients, 413 (62.5%) patients had an m-HS≤3, with 1 (0.2%) patient having a MACE, and 248 (37.5%) patients had an m-HS≥4, with 5 (2.0%) patients having MACEs (P=0.03). CONCLUSIONS: Serial testing of hs-cTnT over 1 hour along with application of an m-HS identified a low-risk population that might be able to be directly discharged from the emergency department.


Asunto(s)
Angina de Pecho/diagnóstico , Servicio de Cardiología en Hospital , Servicio de Urgencia en Hospital , Infarto del Miocardio/diagnóstico , Troponina T/sangre , Adulto , Anciano , Algoritmos , Angina de Pecho/sangre , Angina de Pecho/etiología , Angina de Pecho/mortalidad , Australia , Biomarcadores/sangre , Diagnóstico Diferencial , Europa (Continente) , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/sangre , Infarto del Miocardio/complicaciones , Infarto del Miocardio/mortalidad , Alta del Paciente , Valor Predictivo de las Pruebas , Pronóstico , Estudios Prospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Estados Unidos , Regulación hacia Arriba
6.
Acad Emerg Med ; 23(9): 1004-13, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-27178492

RESUMEN

BACKGROUND: Recent single-center and retrospective studies suggest that acute myocardial infarction (AMI) could be immediately excluded without serial sampling in patients with initial high-sensitivity cardiac troponin T (hs-cTnT) levels below the limit of detection (LoD) of the assay and no electrocardiogram (ECG) ischemia. OBJECTIVE: We aimed to determine the external validity of those findings in a multicenter study at 12 sites in nine countries. METHODS: TRAPID-AMI was a prospective diagnostic cohort study including patients with suspected cardiac chest pain within 6 hours of peak symptoms. Blood drawn on arrival was centrally tested for hs-cTnT (Roche; 99th percentile = 14 ng/L, LoD = 5 ng/L). All patients underwent serial troponin sampling over 4-14 hours. The primary outcome, prevalent AMI, was adjudicated based on sensitive troponin I (Siemens Ultra) levels. Major adverse cardiac events (MACE) including AMI, death, or rehospitalization for acute coronary syndrome with coronary revascularization were determined after 30 days. RESULTS: We included 1,282 patients, of whom 213 (16.6%) had AMI and 231 (18.0%) developed MACE. Of 560 (43.7%) patients with initial hs-cTnT levels below the LoD, four (0.7%) had AMI. In total, 471 (36.7%) patients had both initial hs-cTnT levels below the LoD and no ECG ischemia. These patients had a 0.4% (n = 2) probability of AMI, giving 99.1% (95% confidence interval [CI] = 96.7% to 99.9%) sensitivity and 99.6% (95% CI = 98.5% to 100.0%) negative predictive value. The incidence of MACE in this group was 1.3% (95% CI = 0.5% to 2.8%). CONCLUSIONS: In the absence of ECG ischemia, the detection of very low concentrations of hs-cTnT at admission seems to allow rapid, safe exclusion of AMI in one-third of patients without serial sampling. This could be used alongside careful clinical assessment to help reduce unnecessary hospital admissions.


Asunto(s)
Dolor en el Pecho/etiología , Infarto del Miocardio/diagnóstico , Troponina T/sangre , Síndrome Coronario Agudo/complicaciones , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Estudios de Cohortes , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/sangre , Estudios Prospectivos , Estudios Retrospectivos , Troponina I/sangre
7.
Ann Emerg Med ; 68(1): 76-87.e4, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-26794254

RESUMEN

STUDY OBJECTIVE: We aim to prospectively validate the diagnostic accuracy of the recently developed 0-h/1-h algorithm, using high-sensitivity cardiac troponin T (hs-cTnT) for the early rule-out and rule-in of acute myocardial infarction. METHODS: We enrolled patients presenting with suspected acute myocardial infarction and recent (<6 hours) onset of symptoms to the emergency department in a global multicenter diagnostic study. Hs-cTnT (Roche Diagnostics) and sensitive cardiac troponin I (Siemens Healthcare) were measured at presentation and after 1 hour, 2 hours, and 4 to 14 hours in a central laboratory. Patient triage according to the predefined hs-cTnT 0-hour/1-hour algorithm (hs-cTnT below 12 ng/L and Δ1 hour below 3 ng/L to rule out; hs-cTnT at least 52 ng/L or Δ1 hour at least 5 ng/L to rule in; remaining patients to the "observational zone") was compared against a centrally adjudicated final diagnosis by 2 independent cardiologists (reference standard). The final diagnosis was based on all available information, including coronary angiography and echocardiography results, follow-up data, and serial measurements of sensitive cardiac troponin I, whereas adjudicators remained blinded to hs-cTnT. RESULTS: Among 1,282 patients enrolled, acute myocardial infarction was the final diagnosis for 213 (16.6%) patients. Applying the hs-cTnT 0-hour/1-hour algorithm, 813 (63.4%) patients were classified as rule out, 184 (14.4%) were classified as rule in, and 285 (22.2%) were triaged to the observational zone. This resulted in a negative predictive value and sensitivity for acute myocardial infarction of 99.1% (95% confidence interval [CI] 98.2% to 99.7%) and 96.7% (95% CI 93.4% to 98.7%) in the rule-out zone (7 patients with false-negative results), a positive predictive value and specificity for acute myocardial infarction of 77.2% (95% CI 70.4% to 83.0%) and 96.1% (95% CI 94.7% to 97.2%) in the rule-in zone, and a prevalence of acute myocardial infarction of 22.5% in the observational zone. CONCLUSION: The hs-cTnT 0-hour/1-hour algorithm performs well for early rule-out and rule-in of acute myocardial infarction.


Asunto(s)
Infarto del Miocardio/diagnóstico , Troponina T/sangre , Anciano , Anciano de 80 o más Años , Algoritmos , Electrocardiografía , Servicio de Urgencia en Hospital , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/sangre , Infarto del Miocardio/fisiopatología , Factores de Tiempo
8.
Genes Dev ; 20(17): 2361-72, 2006 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-16921028

RESUMEN

The vertebrate heart possesses autoregulatory mechanisms enabling it first to sense and then to adapt its force of contraction to continually changing demands. The molecular components of the cardiac mechanical stretch sensor are mostly unknown but of immense medical importance, since dysfunction of this sensing machinery is suspected to be responsible for a significant proportion of human heart failure. In the hearts of the ethylnitros-urea (ENU)-induced, recessive embryonic lethal zebrafish heart failure mutant main squeeze (msq), we find stretch-responsive genes such as atrial natriuretic factor (anf) and vascular endothelial growth factor (vegf) severely down-regulated. We demonstrate through positional cloning that heart failure in msq mutants is due to a mutation in the integrin-linked kinase (ilk) gene. ILK specifically localizes to costameres and sarcomeric Z-discs. The msq mutation (L308P) reduces ILK kinase activity and disrupts binding of ILK to the Z-disc adaptor protein beta-parvin (Affixin). Accordingly, in msq mutant embryos, heart failure can be suppressed by expression of ILK, and also of a constitutively active form of Protein Kinase B (PKB), and VEGF. Furthermore, antisense-mediated abrogation of zebrafish beta-parvin phenocopies the msq phenotype. Thus, we provide evidence that the heart uses the Integrin-ILK-beta-parvin network to sense mechanical stretch and respond with increased expression of ANF and VEGF, the latter of which was recently shown to augment cardiac force by increasing the heart's calcium transients.


Asunto(s)
Mecanotransducción Celular/fisiología , Contracción Miocárdica/fisiología , Miocardio/enzimología , Proteínas Serina-Treonina Quinasas/fisiología , Pez Cebra , Actinina/fisiología , Secuencia de Aminoácidos , Animales , Factor Natriurético Atrial/antagonistas & inhibidores , Factor Natriurético Atrial/biosíntesis , Factor Natriurético Atrial/genética , Calcio/metabolismo , Regulación hacia Abajo/genética , Marcadores Genéticos , Humanos , Mecanotransducción Celular/genética , Datos de Secuencia Molecular , Contracción Miocárdica/genética , Proteínas Serina-Treonina Quinasas/deficiencia , Proteínas Serina-Treonina Quinasas/genética , Factor A de Crecimiento Endotelial Vascular/antagonistas & inhibidores , Factor A de Crecimiento Endotelial Vascular/biosíntesis , Factor A de Crecimiento Endotelial Vascular/genética , Pez Cebra/embriología
9.
Behav Res Methods ; 38(1): 1-7, 2006 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-16817508

RESUMEN

Tone detection thresholds for a 10-kHz tone in NMRI mice were determined in psychoacoustic experiments using both a constant-stimuli procedure and a two-down/one-up adaptive-tracking procedure in the same subjects and applying identical threshold criteria (70.7% response probability). Constant-stimuli thresholds were on average 24 dB lower than adaptive-tracking thresholds, and there was a trend indicating that constant-stimuli thresholds were less variable than adaptive-tracking thresholds. Furthermore, in the constant-stimuli procedure the number of trials constituting the psychometric function could be reduced from 100 to 50 trials without a large loss of accuracy of threshold determination. In the constant-stimuli procedure, the threshold value was affected by the threshold criteria. The lowest and least variable constant-stimuli thresholds were obtained by applying signal detection theory and a criterion of d' = 1. Thus, the constant-stimuli procedure in combination with signal detection theory appears to be better suited than the adaptive-tracking procedure to determine auditory sensory thresholds.


Asunto(s)
Percepción Auditiva , Condicionamiento Operante , Ratones/fisiología , Umbral Sensorial , Animales , Femenino , Masculino , Psicoacústica , Psicometría , Sensibilidad y Especificidad , Detección de Señal Psicológica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA