1.
Eur Heart J Cardiovasc Imaging ; 17(4): 447-57, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26232053

RESUMEN

AIMS: The mitral annulus (MA) saddle shape is complex but vital for a normal functioning mitral apparatus. Although conventional parameters of MA geometry such as area and height are helpful, they fall short of describing its complex regional geometry. METHODS AND RESULTS: In this prospective study, novel parameters of MA curvature and torsion were derived from three-dimensional (3D) transoesophageal echocardiography. These quantitative indices were computed in 15 patients with normal valves (age 53 ± 8 years) and in 15 patients with organic significant mitral regurgitation (MR, age 66 ± 11 years), before and after mitral valve repair (MVR). The MA was traced and modelled in mid- and end-systole. Curvature and torsion were computed at 500 points across the MA to derive regional and global indices. Overall, patients with organic MR presented the smallest global curvature and torsion; this decrease in curvature and torsion reflects a loss of tonicity of the MA tissue. These changes were largely corrected with MVR surgery, to higher values, compared with normals. The regional analysis revealed similar trends. The maximal MA curvature was found to be at the MA 'anterior horn', whereas the MA 'posterior horn' had the lowest curvature values. CONCLUSION: Novel MA parameters of curvature and torsion can be computed from 3D echocardiography and provide quantitative characteristics of dynamic regional MA geometry. In patients with organic MR, the reduced regional and global curvatures improve following surgical MVR. These quantitative parameters may help further refine the quantitative description of MA geometry in various mitral valve pathologies and after MVR.


Asunto(s)
Ecocardiografía Tridimensional , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Estudios Prospectivos
2.
J Heart Valve Dis ; 14(4): 476-80, 2005 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-16116873

RESUMEN

BACKGROUND AND AIM OF THE STUDY: Early recognition of subclinical prosthetic valve malfunction may promote early treatment and avoidance of serious complications. Echocardiography cannot be applied on a daily basis; thus, a hand-held device (Thrombocheck) which is capable of detecting subtle changes in the acoustic sounds of prosthetic valve has been developed for the routine home monitoring of heart valve function. Herein is reported the authors' initial clinical experience with this device. METHODS: Seventy-one consecutive patients with one or more bileaflet prosthetic mechanical valves at any position were assessed both by transthoracic echocardiography (TTE) and by Thrombocheck. These patients attended the authors' clinic for either routine echocardiography (n = 62) or for the detection of prosthetic valve malfunction (n = 9). Cinefluoroscopy and transesophageal echocardiography were used selectively to confirm prosthetic valve malfunction. The Thrombocheck was held for 1 min in the subxiphoid position perpendicular to the patient, and indicated either normal function (OK), abnormal function (Warning) or 'no signal'. RESULTS: The study patients had in total 82 bileaflet valves (47 mitral, 31 aortic, four tricuspid). Eight patients (11.3%) had a 'no signal' indication. Of the remaining 63 patients, 10 (15.9%) had a 'warning' alarm (eight patients had current abnormal leaflet motion, one patient had a recent history of abnormal leaflet motion, and one had no evidence of prosthetic valve malfunction). The sensitivity and specificity for detecting abnormal prosthetic valve malfunction were 90% and 98%, respectively. CONCLUSION: The Thrombocheck had an excellent sensitivity and specificity for the detection of prosthetic valve malfunction in a cohort of patients with bileaflet mechanical prosthetic heart valves.


Asunto(s)
Auscultación Cardíaca/instrumentación , Prótesis Valvulares Cardíacas , Monitoreo Ambulatorio/instrumentación , Tromboembolia/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Ecocardiografía , Femenino , Válvulas Cardíacas/cirugía , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Falla de Prótesis , Sensibilidad y Especificidad , Tromboembolia/prevención & control , Terapia Trombolítica
SELECCIÓN DE REFERENCIAS